  1. Replies
    6
    Views
    996

    Motive Air. I agree, this is way off base...

    Motive Air.

    I agree, this is way off base with the setup specs. against all I know. This has been a battle witht he Manufacture.I am going to go with the norm on this one, set it up normal.
  2. Replies
    51
    Views
    3,848

    This has been a pretty good thread, from reading...

    This has been a pretty good thread, from reading both sides the argumnent seems to be the "by the book the way the industry has asked to do the job" and "the practical field not in a perfect world...
  3. Replies
    6
    Views
    996

    Air cooled Chiller from Italy

    I have an air cooled chiller on a site with a relief valve on the liquid line rated at 400#. The high pressure cutout transducer is set at 405# on the discharge line. This is a 407c system. I have...
  4. Replies
    12
    Views
    1,279

    Do you have any specs or a good website...

    Do you have any specs or a good website explaining cold traps.
  5. Replies
    12
    Views
    1,279

    Triple Evac dilema

    I found out a co-worker was doing a triple evacuation on a unit charged with R134. He broke the vaccum each time with R-22. Why I am not sure? He is old school and will only listen to facts on why...
  6. Thread: Trane YCD

    by whitepoundog
    Replies
    11
    Views
    2,349

    unfortuantely you can not estimate the subcooling...

    unfortuantely you can not estimate the subcooling by taking the discharge pressure. Recover the refrigerant weigh it and add taps to the LL.
  7. Thread: Trane YCD

    by whitepoundog
    Replies
    11
    Views
    2,349

    You mentioned a 275# psi at the discharge but did...

    You mentioned a 275# psi at the discharge but did not mention a liquid line #. You can not take subcooling with out the LL pressure. If your liquid line temp was 101 that should make your pressure ...
  8. I am finally getting to go tomorrow. I agree this...

    I am finally getting to go tomorrow. I agree this seems like an external issue other than the pump. It was reversed already as far as I know.
  9. Replies
    8
    Views
    1,002

    Use a Trane disharge air thermostat. Set it to 55...

    Use a Trane disharge air thermostat. Set it to 55 and set the program to control occ/unnocc modes. Let the reheat coils control themselves.
    Not the most efficient way but will work.
  10. [QUOTE=hvac248;3212642]Well kind of, it leads...

    [QUOTE=hvac248;3212642]Well kind of, it leads from the pump to the sump,and I should have said sucking refrigerant vapor instead of air.[/QUOTEi knew what you meant, thanks]
  11. Is the pickup tube on the pump itself?

    Is the pickup tube on the pump itself?
  12. Ok more peices are coming in, it looks like...

    Ok more peices are coming in, it looks like another contractor replced it last year. I could not get there today. But I will look into the gasket.
  13. copeland compressor oil pressure problems

    Ok I do not have all the facts yet, but I want to get some outside thoughts. My tech told me he has a 6R compressor, replaced the oil pump because it was not making pressure. It was only delivering...
  14. Replies
    12
    Views
    1,916

    I am assuming you took the actual DA reading with...

    I am assuming you took the actual DA reading with a probe strapped to the Trane DA sensor.

    The sensors go out of calibration, quite often. Carry a few on the truck like CG said.
  15. Replies
    8
    Views
    1,065

    Do the right thing and sub out Trane to come take...

    Do the right thing and sub out Trane to come take a look, then take a summit operator class for starters. Trane offices have them annually. Believe me Trane techs are online with tech support as...
  16. Replies
    2
    Views
    543

    you can attempt to pump the compressor down, or...

    you can attempt to pump the compressor down, or you can use a recovery machine to pump the refrigerant into the high side.

    whatever you do make sure there is no pressure in the compressor before...
  17. Replies
    18
    Views
    2,456

    Yeah I agree, The more I think of it the more I...

    Yeah I agree, The more I think of it the more I think that these guys doing it are not our technical finest just thought I was missing something, your never to old to learn.

    Thanks for the reply.
  18. Replies
    18
    Views
    2,456

    megger uses

    A couple of co-workers use a megger to as they say " I'm checking between the windings". I ask them why not use an appropriate ohm meter to check between windings. I get blank stares from them.Unless...
  19. Check the oil with an acid test kit once annually...

    Check the oil with an acid test kit once annually if you are seasonal, twice if it runs all year. That should be sufficient.
  20. Replies
    26
    Views
    2,053

    Hope your joking about the breaker

    Hope your joking about the breaker
  21. Replies
    2
    Views
    496

    That is usually how it goes. Two jobs I have seen...

    That is usually how it goes. Two jobs I have seen the cap was checked (OK) then swapped out because I never trust my MF meter. Still the motor was reversed. Wiring was correct and volts normal.
  22. Replies
    2
    Views
    496

    PSC motor just reversed

    Okay, I am sure at somepoint I knew the answer to this once but my mind ain't what it used to be. Here goes. Why does a PSC motor sometimes just reverse. Capacitor is still good but the motor just...
  23. Replies
    159
    Views
    23,418

    R-11 is phased out, yet readily available. R-22...

    R-11 is phased out, yet readily available. R-22 is also being phased out, and that will available, the same for 123, it is stockpiled. Lp machines are the way to go. I do agree with the loyalty...
  24. Replies
    19
    Views
    1,210

    Common is used in so many ways in our field it is...

    Common is used in so many ways in our field it is bound to get confusing. But I Agree with mad hat in a 230v circuit there is no technical common, they are both hot. L1 & L2.
  25. Replies
    10
    Views
    3,629

    what is a the model and serial, that is...

    what is a
    the model and serial, that is definately got to be mistake.