  1. Replies
    25
    Views
    1,125

    Did you get the system working? It's hard to get...

    Did you get the system working? It's hard to get water out of a system.
  2. Replies
    8
    Views
    651

    The Mini-Splits are doing a fine job. The only...

    The Mini-Splits are doing a fine job. The only problem-No one has parts for them yet. But should not need any parts for quite a few years. Can get units with up to 8 outlets now.
  3. Replies
    4
    Views
    359

    Is the stat. fan setting set on auto or on? Let...

    Is the stat. fan setting set on auto or on? Let your neighbor help you out.
  4. Replies
    6
    Views
    301

    He is only checking the pressure. Any gauge can...

    He is only checking the pressure. Any gauge can be used.
  5. Thread: Delta T Problem

    by lentz
    Replies
    55
    Views
    2,002

    Check the hole behind the stat. This needs to be...

    Check the hole behind the stat. This needs to be sealed off. Warm air could be coming into the back of the stat. and causing the big difference in temperature. And check the temperature that is...
  6. Replies
    1
    Views
    272

    Shading would help a little. But nothing with end...

    Shading would help a little. But nothing with end six feet from the top of the unit and two feet from the sides..
  7. Replies
    13
    Views
    596

    You have troubles that are going to have to solve...

    You have troubles that are going to have to solve by a pro that knows what he is doing. Every thing go to the bad and has to be replaced.
  8. Replies
    9
    Views
    469

    A lot of units have a little recess place where...

    A lot of units have a little recess place where the primary drain in connected. Make sure the 3/4 adapter is not one that has a small opening inside of it. This is for a secondary drain. I put a...
  9. Replies
    25
    Views
    1,125

    We have used only flared filters dryers for...

    We have used only flared filters dryers for years. Put a valve on one side and the condenser has a valve on the other side. Then you can change the filter dryer real easy.
  10. Replies
    31
    Views
    1,291

    In 50 some years of HVAC work I have never seen...

    In 50 some years of HVAC work I have never seen anything that bad. i hope you have not paid him in full. Call the county inspector and ask him to come by and see this. I will bet this has not been...
  11. Let us know if you got it fixed? And how is it...

    Let us know if you got it fixed? And how is it working?

    Have a good WEEKEND
  12. Replies
    220
    Views
    12,233

    That sure looks like sheet rock dust.

    That sure looks like sheet rock dust.
  13. Replies
    12
    Views
    712

    R-22 is cheaper that it has been in years. Every...

    R-22 is cheaper that it has been in years. Every supply house I visit even has it in the walk way.
  14. Thread: Undersized AC

    by lentz
    Replies
    42
    Views
    1,617

    Don't forget to seal behind those electric...

    Don't forget to seal behind those electric outlets and switches on the outside walls. I take the covers off and spray foam all around the boxes. Use the non flammable kind.
  15. Replies
    3
    Views
    321

    Those blocks are most likely for shipping only.

    Those blocks are most likely for shipping only.
  16. Replies
    11
    Views
    433

    You can see where the set screw was on the old...

    You can see where the set screw was on the old motor shaft. Put the new blade back on the new motor at the same place. One or more of the blades on the new fan are bent out of shape. A pro can take...
  17. Replies
    9
    Views
    573

    Is the system working OK now? Have "A" check the...

    Is the system working OK now? Have "A" check the indoor unit to make sure it is not leaking and if it is ask him to repair it or install the right size new unit indoors. Then you have a new unit.
    ...
  18. Replies
    12
    Views
    712

    If you can--Now is the time to change your...

    If you can--Now is the time to change your system. Get at least 3 prices if possible and talk over the quote to see what you are getting. Get the 10 year warranty on labor and all parts. Amana has a...
  19. I sure hate you are still having problems. You...

    I sure hate you are still having problems. You have received good information from the above comments. Please let us know when you get it working right. After you work outside all day it is nice to...
  20. Replies
    8
    Views
    206

    Whoever install your stat-Have him come back and...

    Whoever install your stat-Have him come back and fix the problem. Stats do go bad--just like everything else.
  21. I have had to be real careful in change outs from...

    I have had to be real careful in change outs from R-22 to R 410a. The rating are not the same. Try to get the system checked out and maybe the new system is to small.
  22. Fan motors have not had oiling ports for years....

    Fan motors have not had oiling ports for years. Are you sure the oil is coming from the fan?
    Have a pro to check out your unit. Did you put the fan back on the shaft where it was before? Is the coil...
  23. Replies
    7
    Views
    287

    It is units that are used on project jobs....

    It is units that are used on project jobs. Installation is the main part that keeps your AC working. Air-Ease is made by Allied-Air-Enterptises
  24. Do you see any frost build up on any part of the...

    Do you see any frost build up on any part of the coil?
  25. Replies
    18
    Views
    490

    You have had your share of troubles. Hope things...

    You have had your share of troubles. Hope things will be better from here on out. Have had trouble with Amana coils.