  1. Replies
    28
    Views
    4,762

    My current filter is just ahead of the furnace...

    My current filter is just ahead of the furnace (see picture below). I'm thinking of having them put a media filter in this area when they redo and enlarge this area:

    343801
  2. Replies
    2
    Views
    844

    Thanks ill run that by my contractor

    Thanks ill run that by my contractor
  3. Replies
    2
    Views
    844

    Filter Recomendation

    I'm having the return duct entering the furnace redone next week and wanted opinions on value of upgrading to a filter cabinet? I moved in the house two years ago and have been confused on the...
  4. Replies
    28
    Views
    4,762

    New question on filters: On my Tempstar Model...

    New question on filters:

    On my Tempstar Model T9MVX100120A1 Furnace the manual instructions on filters is pretty confusing. It basically says replace filter with what was installed. Since I...
  5. Replies
    28
    Views
    4,762

    Yes it's 3 1/2 x 11 1/2". Here are some pictures...

    Yes it's 3 1/2 x 11 1/2". Here are some pictures and this is connected to that flex duct in other picture.

    342121342131342141

    Sorry one is upside down...

    Yes there are two returns in the...
  6. Replies
    28
    Views
    4,762

    That supply seems weak due to it coming up under...

    That supply seems weak due to it coming up under vanity and coming through a small kick plate cover that heats a few feet out. I was thinking it might get better flow if I had a full size vent in...
  7. Replies
    28
    Views
    4,762

    Have a new idea: What would the issues be if...

    Have a new idea:

    What would the issues be if we teed off the existing supply shown in this picture

    342031

    Sorry need to rotate clockwise for proper orientation...

    This feeds the master...
  8. Replies
    28
    Views
    4,762

    Liskywalker... Thanks, On the return air I...

    Liskywalker...

    Thanks, On the return air I think that is what Contractor 6 has proposed along with sealing up the two returns upstairs. I"m leaning pretty hard that direction so far...
  9. Replies
    28
    Views
    4,762

    thought it may be helpful to post pictures of...

    thought it may be helpful to post pictures of master area.

    One shows master with windows / door on north side of 2nd story, vaulted ceiling, you can see one vent under left hand window other is...
  10. Replies
    28
    Views
    4,762

    picture 1 this is the between floor area...

    picture 1
    this is the between floor area ...where?
    are you taking these pics thru an attic access? 3 car garage with the far end stall attic space uninsulated, except the wall that backs to the M...
  11. Replies
    28
    Views
    4,762

    340971340981340991341001341011 Attached are...

    340971340981340991341001341011

    Attached are pictures of what I found at the knee wall in uninsulated garage attic space upon moving in. You can see the open space and then I took pictures through...
  12. Replies
    28
    Views
    4,762

    I test ducts for leakage...but if you can't get...

    I test ducts for leakage...but if you can't get there..
    how much of your ductwork is visible/acessable? None - It's all sealed in dry wall except the mech room

    Appreciate the info on...
  13. Replies
    28
    Views
    4,762

    1. Original contractor: 2nd unit in attic. this...

    1. Original contractor: 2nd unit in attic.
    this would be leaving original unit in place for downstairs & basement and adding how big of a second unit? Yes original left in basement add 3 ton air...
  14. Replies
    28
    Views
    4,762

    No check of the ducts themselves for leaks. I'll...

    No check of the ducts themselves for leaks. I'll add that to the list

    Thanks for the input
  15. Replies
    28
    Views
    4,762

    The "2nd" contractor did plug sf / windows etc...

    The "2nd" contractor did plug sf / windows etc into a software program. Others seemed to count registers per level and sf. Seems one unit trying to condition 3 levels is a challenge unless...
  16. Replies
    28
    Views
    4,762

    On zoning: Are you referring to the control...

    On zoning: Are you referring to the control damper system as a possible option? The way I'm reading your reply is zoning the 2 runs only would be detrimental but the more sophisticated individual...
  17. Replies
    28
    Views
    4,762

    Two Story Air Flow Issues

    New member located in Utah. I moved into my home two years ago and have found our 2nd story master bedroom is 5 degrees cooler in the winter and warmer in the summer. We have one unit in the...
  18. Thread: Test

    by Jake12
    Replies
    14
    Views
    1,492

    Test

    New member test