  1. Replies
    25
    Views
    6,154

    Don't go getting the wrong impression. I ma not...

    Don't go getting the wrong impression. I ma not someone that goes out there and starts jumping things out when they go bad. I know this is gonna sound contradicting but I take alot of pride in my...
  2. Replies
    25
    Views
    6,154

    I would like to see why you guys are so against...

    I would like to see why you guys are so against this. I'm sorry but I have had way too many units with 2-5min defrosts due to a bad sensor or the plate the sensor is mounted on sees 50 F well before...
  3. Replies
    29
    Views
    3,602

    Work for a commercial refrig/heat cool/ company ...

    Work for a commercial refrig/heat cool/ company

    We only go out for real emergencies.......walk-in down, ice machine, or kitchen exhaust (fire alarm)

    get 4 hours OT pay plus 1 1/2 pay from time...
  4. scientific testing lab. Had a reach in that used...

    scientific testing lab. Had a reach in that used two small 1/4 or 1/3 comps. Can't remember exactly as it has been a while ago.
    Anyway the first comp R-12 would run unit a certain set temp. The two...
  5. Replies
    25
    Views
    6,154

    I use time clocks on coolers that stock kegs or...

    I use time clocks on coolers that stock kegs or beer. Can set temp to 34 and in conjunction with the glycol unit will have 38-39 temp at the taps.
    Time clock also useful when the is a icing up...
  6. Replies
    5
    Views
    944

    You could also use a glycol beer unit and just...

    You could also use a glycol beer unit and just run a small pump circulating the SW through heavy tubing or PVC in the glycol bath. A little more involved but you have an almost endless capacity no...
  7. Replies
    5
    Views
    944

    I've come across that same problem. Best I found...

    I've come across that same problem. Best I found was $285 at a place in Brooklyn, NY.
    I was going to build my own for my tank but then I figured cost of parts vs buying one and it was about the...
  8. Replies
    6
    Views
    1,044

    Want to hear something funny. That's the first...

    Want to hear something funny. That's the first I've heard of a cond water valve leaking water on a hosh. That's why I was asking about the leak and didn't put 2 & 2 together.
    Let me add that I...
  9. Replies
    6
    Views
    1,044

    First change the drier and start over. Also you...

    First change the drier and start over. Also you have me confused. Says you were called out for water leaking into ice bin but you end up changing the cond. regulating valve?
    I understand that it...
  10. Replies
    5
    Views
    4,688

    I am adding a 3rd rtu unit to a store. I need to...

    I am adding a 3rd rtu unit to a store. I need to know the size of the 2 current units so that I can size properly for a 3rd.

    Model is : GCS16-653-125-3Y

    I want to say 5 ton but I've seen...
  11. Replies
    22
    Views
    1,470

    Another 30yr old metal fan here. Huge metallica...

    Another 30yr old metal fan here. Huge metallica fan but Korn seems to be my new current fix.
    Grew up with all the 80's metal and hair bands
  12. Replies
    3
    Views
    1,365

    obviously check press 5 min into harvest. A...

    obviously check press 5 min into harvest. A hoshizaki float is a magnectic switch and not a mechanical one. That's why if it's down a little and you tap it, it goes into harvest. Check the screen...