  1. Replies
    13
    Views
    2,561

    Definitely. Hopefully, that goes without saying....

    Definitely. Hopefully, that goes without saying.

    Ran across one this summer where the company (out of business now, of course) sold an extended (in house) warranty.

    How do you...
  2. Replies
    21
    Views
    2,209

    First; there are not enough registers (airflow)....

    First; there are not enough registers (airflow).

    Secondly, you might try "dumping" some heat under the floor.

    Thirdly, add more registers or increase the airflow and then zone.

    My family...
  3. Replies
    13
    Views
    2,561

    TempStar used to require that you had to have the...

    TempStar used to require that you had to have the furnace "serviced" once a year to keep the 10 year labor protection in effect.

    Don't fall for that trick. Otherwise, I think the extended...
  4. Replies
    33
    Views
    1,101

    A public servant should be held to higher...

    A public servant should be held to higher standards because of the public trust.

    They should throw the bum into jail and throw away the key.

    This is the tip of the iceberg for this thief.
  5. We did a home ur size with one furnace and one...

    We did a home ur size with one furnace and one A/C and eight (8) zones.

    Works like a dream.
  6. Replies
    23
    Views
    1,674

    Looks like a seam to me. I probably would...

    Looks like a seam to me.

    I probably would believe to two companies that said it was okay.
  7. Replies
    28
    Views
    2,181

    Load calcs. are great, unless you can't get the...

    Load calcs. are great, unless you can't get the air where it's needed.

    You have a 3 ton (27 yrs.) and someone wants to install a 4 ton. Mistake....in so many ways.

    Sounds like a 3 ton 2-stage...
  8. Replies
    18
    Views
    993

    With the ductwork in the attic and the (sun)...

    With the ductwork in the attic and the (sun) exposure, the 2.5 ton is probably the one for you.

    I get by because the A/C is NEVER off (my wifes fear of dust).

    Most people will open the...
  9. Replies
    18
    Views
    993

    My home is a 2,250 sq. ft. 2 story built in 1946....

    My home is a 2,250 sq. ft. 2 story built in 1946. East/west exposure with awning, however.

    No insulation in the sidewalls and terrible windows, although they do have (lousy) alum. storms.

    At...
  10. Replies
    18
    Views
    993

    Where will the new ductwork go? Attic, basement...

    Where will the new ductwork go? Attic, basement or crawl space? How is the home insulated, windows and storm doors?

    What is the homes exposure to the sun? Does the home have awnings or shade...
  11. Replies
    10
    Views
    1,394

    B.L. I've lived in my home for 32 yrs. The...

    B.L.

    I've lived in my home for 32 yrs. The home had an old GE 2.5 ton. It cooled; i.e. dehumidified, like a dream. I could keep the stat at 76-78 and be comfortable.

    Replaced it with a newer...
  12. How many returns are there? Take a grille...

    How many returns are there?

    Take a grille (or 2) off and notice the differance.
  13. They either don't know or don't care. Both of...

    They either don't know or don't care. Both of which is a bad thing.
  14. A VS motor will NOT be quieter if there is not...

    A VS motor will NOT be quieter if there is not enough RA.

    People think a VS motor is a cure all. Wrong.
  15. Replies
    4
    Views
    775

    It boils down to how its designed, installed and...

    It boils down to how its designed, installed and service after the sale.

    Spend some time reading these posts and you'll understand what I'm trying to say.
  16. Replies
    3
    Views
    392

    Normally, the high static is caused by a lack of...

    Normally, the high static is caused by a lack of return air; i.e. filter (size or type), ductwork (too small), or grilles (number and/or size).

    I saw a new (5 year old) house last year with a bad...
  17. Replies
    7
    Views
    567

    We have some LP systems in the country. I size...

    We have some LP systems in the country. I size the gas line as if they'll get natural gas someday.
  18. Unfortunately, this is probably true. But it...

    Unfortunately, this is probably true. But it doesn't take a rocket scientist to know why this is..............cost.

    If flex is done incorrectly (metal the same thing) you'll be sorry for a long...
  19. Replies
    54
    Views
    3,795

    I had hear that 35 years ago from a guy that...

    I had hear that 35 years ago from a guy that really knew his stuff.

    But like you mentioned it's counter intuitive to logical thinking.

    Thank you for confirming what I had been told. I think...
  20. Replies
    7
    Views
    748

    I assume the 14" went to a 14" tee and then...

    I assume the 14" went to a 14" tee and then reduces (both ways) to 10"?

    That would be 400 cfm each way. Remember flex kills airflow.
  21. I'm surprised that the 5 ton systems will...

    I'm surprised that the 5 ton systems will accomplish the 15.00 SEER (no problem there), 12.50 EER (problem ?) and 8.5 HSPF (problem ?).

    I'm too lazy to look it up. Let me know.
  22. Replies
    10
    Views
    895

    FE4ANF006010 (10kw) or 011 (11 kw) or (015) you...

    FE4ANF006010 (10kw) or 011 (11 kw) or (015) you guessed it.

    I would recommend the Infinity zone system and the Infinity control.

    It's a really nice (quiet) zone system that doesn't require a...
  23. A five ton system requires a lot of airflow and...

    A five ton system requires a lot of airflow and knowledge. Go with the best company. The product is the last thing to worry about. The Bryant is variable speed. Is the Am. Std. also variable?
  24. Replies
    7
    Views
    748

    Sounds like a real botch job. 14" pipe is...

    Sounds like a real botch job.

    14" pipe is good for 1,000 cfm. 10" pipe is good for 400 cfm. 8" pipe is good for 240 cfm. 6" pipe is good for 110 cfm.

    When flex is used, reduce the airflow...
  25. Replies
    54
    Views
    3,795

    I sell York but used to sell Carrier. I lean...

    I sell York but used to sell Carrier. I lean towards the Carrier (slightly).

    That said, it ALWAYS depends on the company you're dealing with first and formost.