03-26-2013, 11:31 PM
Thread: JCI FX Customer Training Manual ???
by NightrainATC- Replies
- 2
- Views
- 260
JCI FX Customer Training Manual ???
Anyone have a link to a JCI FX customer training manual? One you would use for a job closeout training session that is not too elaborate but enough information to cover topics such as system...
-
12-04-2012, 02:43 PM
Thread: MODBUS RS-485 cable???
by NightrainATC- Replies
- 3
- Views
- 622
MODBUS RS-485 cable???
I am working on a project which requires MODBUS integration to Automatic Transfer Switches. I can't recall the ATS manufacturer but we were told that they recommend we use one of the following...
-
10-11-2012, 05:08 PM
- Replies
- 7
- Views
- 656
I called Belimo today and the guy told me they do...
I called Belimo today and the guy told me they do not have high temp valves and that their actuators are rated to 122F. Any idea on the model#. I'll double check their website. Dave, I'll look into...
-
10-11-2012, 03:42 PM
- Replies
- 7
- Views
- 656
high temp electronic valve/actuators???
We have a customer who wants to convert all of his existing pneumatically controlled 3/4", 2-way steam valves in radiators to electronic for BAS control. The existing valves are mounted inside the...
-
12-18-2011, 03:35 PM
- Replies
- 8
- Views
- 680
Automated Logic Bacnet MS/TP vs Arcnet
I need to tie in a JACE to existing ALC "SE" and "ZN" controllers via BACnet MS/TP but it appears the field bus is Arcnet. The literature for the controllers read Arcnet or BACnet MS/TP...
-
09-09-2011, 08:12 AM
- Replies
- 23
- Views
- 2,153
MM82, Thanks a lot for the info. I'll take a...
MM82,
Thanks a lot for the info. I'll take a look at it today. Based on your expertise, would this driver be the best option for what I'm looking for and will it bring in all of the controllers... -
09-09-2011, 08:08 AM
- Replies
- 23
- Views
- 2,153
Matrix, I knew someone would ask me this but I'd...
Matrix,
I knew someone would ask me this but I'd be glad to answer. We actually performed a project there a while ago with an NAE. We also have NAEs at their other facilities so we will be... -
09-08-2011, 09:36 AM
- Replies
- 23
- Views
- 2,153
Barber-Coleman Network 8000 Integration??
Hello,
I'm looking to help out a good customer of ours by integrating to an existing Barber-Coleman Network 8000 System using a Johnson Controls System. Although we currently have a NAE onsite, it... -
05-12-2011, 09:22 PM
- Replies
- 20
- Views
- 1,577
How do you apply for a Pro membership and what...
How do you apply for a Pro membership and what are the benefits? Thanks.
-
05-12-2011, 09:01 PM
- Replies
- 20
- Views
- 1,577
Thanks. I figured you had extended memory. I'm...
Thanks. I figured you had extended memory. I'm going with extra memory anyway to accommodate future controllers.
Question: If I had a job without the FX server and it had (3) FX Supervisory... -
05-11-2011, 07:41 AM
- Replies
- 20
- Views
- 1,577
Mechdorn, Thanks. This is the type of...
Mechdorn,
Thanks. This is the type of information I was looking for. I too will be implementing a FX Server so is it safe to use 1600 pts per trunk as a max guidline?
At this time, we are... -
05-09-2011, 07:37 PM
- Replies
- 20
- Views
- 1,577
CCIKelly, My profile has been updated, thanks....
CCIKelly,
My profile has been updated, thanks. I will look into a pro membership but if you could provide any advice in this thread, it would be appreciated.
Thanks. :cheers: -
05-09-2011, 05:28 PM
- Replies
- 20
- Views
- 1,577
We are an ABCS but currently have access to both...
We are an ABCS but currently have access to both FX & Metasys Lines. I'm looking at around 450-500 FEC field controllers (400 of which are FEC VMA VAV Controllers and the others for AHUs and Hot...
-
05-09-2011, 04:51 PM
- Replies
- 20
- Views
- 1,577
This is a real job. The FECs will be controlling...
This is a real job. The FECs will be controlling AHUs, VAVs and Hot Water System equipment and will communicate to the FX Supervisory Controllers via BACnet MS/TP.
I'm figuring it will be best... -
05-09-2011, 02:24 PM
Thread: CCN Wireless Ethernet Bridge
by NightrainATC- Replies
- 4
- Views
- 542
Ottoreload, I'm working on a project where I...
Ottoreload,
I'm working on a project where I have to run my own Ethernet network between building controllers.....one being in a remote building (approx 500 feet between buildings with no critical... -
05-09-2011, 11:25 AM
- Replies
- 20
- Views
- 1,577
Meaning what.....bus length or cable type? ...
Meaning what.....bus length or cable type? FYI...the bus cable will be 22awg, 3-conductor shielded for BACnet communication over the FC bus.
-
05-08-2011, 06:35 PM
- Replies
- 20
- Views
- 1,577
By the way, the Johnson Field Controllers coming...
By the way, the Johnson Field Controllers coming off of the FX Supervisory Controllers will be FEC BACnet Controllers.
Thanks. -
05-08-2011, 04:54 PM
- Replies
- 20
- Views
- 1,577
Johnson FX20/60/70 Capacities + Integration
Is there anyone who has extensive experience with these controllers? I was always curious to know how many controllers can be handled by each version of the FX Supervisory Controllers....although...
-
05-03-2011, 07:54 AM
Thread: Barber-Colman Network 8000 LCM
by NightrainATC- Replies
- 6
- Views
- 1,613
It would be appreciated if you could also send me...
It would be appreciated if you could also send me manuals on this system. I am dealing with a site that has 4-GCM's, GCS's, and MicroZone I & II Controllers.
My email is Email Address's Belong in... -
10-28-2010, 06:34 PM
Thread: JCI FX vs LX LON Controllers
by NightrainATC- Replies
- 9
- Views
- 1,412
JCI FX vs LX LON Controllers
Anybody have any experience with any of these JCI LON Controllers (FX vs LX). Please list pros & cons if possible.
We use the FX Controllers a lot but with N2 and BACnet cards. We have never used... -
02-26-2010, 11:19 AM
Thread: Trane/LON Experts
by NightrainATC- Replies
- 2
- Views
- 507
Trane/LON Experts
Hey guys,
I'm working on a job where I'm looking at installing (160+) JCI LX Lon-based controllers or TEC Lon-based communicating thermostats under 2-new Trane BCU LonTalk comm5 links for fan coil... -
02-24-2010, 07:20 AM
Thread: Trane Summit Bacnet interface to JCI
by NightrainATC- Replies
- 4
- Views
- 850
Great information and suggestions. We are doing...
Great information and suggestions. We are doing the programming and do have extremely seasoned programmers although it will be a learning curve because of our lack of immediate knowledge of Trane's...
-
02-23-2010, 07:00 PM
Thread: Trane Summit Bacnet interface to JCI
by NightrainATC- Replies
- 4
- Views
- 850
Thanks Scrooloose, Option#1) What do you mean...
Thanks Scrooloose,
Option#1) What do you mean by SCC profile? Is there anyway to determine this by way of literature? Based on your suggestions, it appears option#1 would definitely be the best... -
02-22-2010, 11:01 PM
Thread: Trane Summit Bacnet interface to JCI
by NightrainATC- Replies
- 4
- Views
- 850
Trane Summit Bacnet interface to JCI
Gentlemen,
I'm working on a project that requires an existing campus multi-site Trane Summit System to integrate to a new building's JCI system. I received help from a few people on here... -
02-21-2010, 10:19 AM
Thread: Trane CPL info
by NightrainATC- Replies
- 17
- Views
- 1,674
Please provide to me as well if available. ...
Please provide to me as well if available.
Thanks a lot!!!