  1. Replies
    3
    Views
    108

    line set buried in the wall

    Doing a whole replacement attic system where line set replacement is not possible its inside the wall.while removing the old system i notice it was not BRAZED but soldered.I am thinking about putting...
  2. Replies
    1
    Views
    184

    LENNOX VENTING QUESTON

    The venting chart on the e195 furnaces only gives the footage for pipe with the number of 90 degree elbows.Is it correct that two 45 degree elbows equal one 90 degree elbow?
  3. Replies
    1
    Views
    161

    I always use a good air scoop and never have any...

    I always use a good air scoop and never have any issues.
  4. Replies
    0
    Views
    135

    EMI MINI SPLIT ISSUE

    Mod #zha2400 heat pump model,customer tells me the outdoor fan never shuts off.Put in high cool mode suction is 120psi and cooling well shut system of and outdoor fan never shuts off so i take the...
  5. Replies
    2
    Views
    337

    Going there in the am to check it out,it sounds...

    Going there in the am to check it out,it sounds like its coming from the back of the heat exchanger but thats just me
  6. Replies
    15
    Views
    1,485

    Service is up a tad and thats it,had 2 customers...

    Service is up a tad and thats it,had 2 customers this week decide to buy there parts online not sure if they called back as there number is now blocked.The only furnace changeout i did was 3 weeks...
  7. Replies
    2
    Views
    337

    Lennox el195 clicking sound

    Lennox el195 installed 2 weeks ago and the customer can hear a clicking sound coming from the inducer and from the vent pipe outside.I have always heard a faint sound from all of these but run with...
  8. Replies
    20
    Views
    1,806

    it's vented with 2 inch 35 feet total with...

    it's vented with 2 inch 35 feet total with fittings I went there today made sure there was enough pitchback on the vent pipe also thinking if there was built up water when the inducer shut off any...
  9. Replies
    20
    Views
    1,806

    i am going there in the morning to see what i find

    i am going there in the morning to see what i find
  10. Replies
    20
    Views
    1,806

    No water in collector box.I pull inducer and...

    No water in collector box.I pull inducer and drain it it did this a week ago and I checked it 3 days ago and everything seemed to be draining fine I could not hear any water in inducer
  11. Replies
    20
    Views
    1,806

    Flu is pitched with no standing water in...

    Flu is pitched with no standing water in pipe,might locate trap at collector box it runs for a week that has me stumped
  12. Replies
    20
    Views
    1,806

    Lennox el296v drainage issue

    I have a el296070 furnace that runs fine for 2 weeks and then the inducer fills with water and shuts the unit down.The trap is not installed at the collector its at the rear of the furnace about 30"...
  13. Replies
    1
    Views
    279

    Coleman roof jack question

    I am changing a coleman model number 4084a656 to an updated model number dgaa075bdtb and need to know if the roof jack jacks are compatible?The one thats there is in great shape and changing it is...
  14. Replies
    2
    Views
    363

    Lennox vent termination kits

    Anyone using the diversitech hvent2 or hvent3 for vent terminations?There half the cost of the lennox ones.
  15. Replies
    5
    Views
    562

    ICP pressure switch issue

    Icp mod n8npm050b from 2006,the burner lights for 20 seconds and goes out.Flame sensor was good check pressure switch operation which closes at -.58 and goes to .-64 but when the burner lights it...
  16. Replies
    7
    Views
    564

    I will do that Jeep Sent from my Torque using...

    I will do that Jeep

    Sent from my Torque using Tapatalk
  17. Replies
    7
    Views
    564

    Thanks dawg i updated my profile and sent you a...

    Thanks dawg i updated my profile and sent you a message also
  18. Replies
    7
    Views
    564

    LG LS090CE MINI SPLIT

    Does anyone have a troubleshooting guide or parts manual for this mini-split,the comp starts but the condensing unit fan motor never starts and the system shuts down in a few min.
  19. Replies
    3
    Views
    414

    Subcool reading was taken at the condenser ...

    Subcool reading was taken at the condenser

    Sent from my Torque using Tapatalk
  20. Replies
    3
    Views
    414

    76 degrees Sent from my Torque using Tapatalk

    76 degrees

    Sent from my Torque using Tapatalk
  21. Replies
    3
    Views
    414

    H/V CHARGING ISSUE

    New system startup 2.5 ton r-410 h/v system readings are,s/h=12,s/c=3 12 deg d/t, low side 118psi,high side 195 psi.The first floor is a walkout basement temp was 70 deg second floor 75 deg both have...
  22. Baldies got it right there I've had four leakers...

    Baldies got it right there I've had four leakers all c6 miles to the three years old

    Sent from my Torque using Tapatalk
  23. Thread: run cap question

    by splus
    Replies
    51
    Views
    4,358

    I would change it to the right one for sure what...

    I would change it to the right one for sure what will it harm the motor having the bigger one on there

    Sent from my Torque using Tapatalk
  24. Thread: run cap question

    by splus
    Replies
    51
    Views
    4,358

    run cap question

    Was on a call where there was a 7.5 cap on a motor that called for a 5mfd cap,was installed 2 years ago and running fine.Will this be okay if left like this?
  25. My company WAS installing nordyne equipment for...

    My company WAS installing nordyne equipment for 15 yearswith no issues until the microchannel systems came out.Most leakers dont show up until the second year and trying to find them have been not...
  26. Replies
    2
    Views
    299

    Thanks dawg Sent from my Torque using Tapatalk

    Thanks dawg

    Sent from my Torque using Tapatalk
  27. Replies
    2
    Views
    299

    Lennox c33 liquid line stub

    Is the 3/8od liquid line stub available as a part if so i need a part number,also the one that comes with the coil has a teflon o-ring on it do i need to install the o-ring that comes inside the coil...
  28. Replies
    2
    Views
    338

    So a standard 2.5 ring will work if OEM is larger...

    So a standard 2.5 ring will work if OEM is larger

    Sent from my Torque using Tapatalk
  29. Replies
    2
    Views
    338

    Trane blower motor question

    Trane part number moto4717 3/4 hp motor,need to know if a standard motor with 2.5 inch resilient rings will work I seem to remember some of these have 2/5/8 rings
  30. Replies
    12
    Views
    898

    The chimney has a tile liner in it now its been...

    The chimney has a tile liner in it now its been running fine for 2 days now told the customer we need to evaluate the chimney and possibly put a alum liner in it

    Sent from my Torque using Tapatalk
  31. Replies
    12
    Views
    898

    The chimney is on the outside of the house and we...

    The chimney is on the outside of the house and we have had a week off record cold here below zero wind chill

    Sent from my Torque using Tapatalk
  32. Replies
    12
    Views
    898

    Yes it will vent fine no spillage at the water...

    Yes it will vent fine no spillage at the water heater I haven't taken any draft reading yet its been venting and the boiler and then cycling for 24 hours

    Sent from my Torque using Tapatalk
  33. Replies
    12
    Views
    898

    After pulling the vent pipe off of the vent...

    After pulling the vent pipe off of the vent damper of the boiler letting it bent into the basement for a minute putting the vent pipe back on the damper in its been venting fine

    Sent from my...
  34. Replies
    12
    Views
    898

    The boiler is 125000 BTU with a 40,000 BTU...

    The boiler is 125000 BTU with a 40,000 BTU standing pilot water heater jimmy is on the outside of the house 8 inch tile lined

    Sent from my Torque using Tapatalk
  35. Replies
    12
    Views
    898

    It extends one inch into the flu I checked it a...

    It extends one inch into the flu I checked it a fee hours later and it was venting fine

    Sent from my Torque using Tapatalk
  36. Replies
    6
    Views
    765

    Triangle tube boiler with the trimax control is a...

    Triangle tube boiler with the trimax control is a nice boiler.W/M makes a fire tube boiler also which is pretty much the same heat exchanger.
  37. Replies
    12
    Views
    898

    Boiler draft issue

    Get to a no heat call on a natural draft spark ignition boiler and find the roll out under the draft hood tripped.Boiler fires and I notice its not venting at all as in the vent pipe after the vent...
  38. Thread: Wet Switches

    by splus
    Replies
    9
    Views
    1,255

    I have used a hair dryer but have found to just...

    I have used a hair dryer but have found to just replace it as most will trip if there is high humidity in the attic area there very sensitive after you dry them
  39. Replies
    2
    Views
    608

    LINE SET SIZE QUESTION

    Got a trane 4ttb3018 with a 4txc18 coil i serviced it a few years back and it has a 5/8suction with a 1/4 liquid line.another company looked at it as i was 5 days out and said the liqiud line size...
  40. Replies
    2
    Views
    647

    ADP TXV PART NUMBER

    adp #te36430c245b 5-ton made in 2007 its a r-22 coil with txv i need a r-410 valve i did have one from a trane 4txc coil but the threads dont match up anyone know the adp or trane part number for the...
  41. Replies
    4
    Views
    1,005

    Are the condensing units microchannel?I am going...

    Are the condensing units microchannel?I am going to install a few furnaces and see i do like the condensate trap setup on them compared to the nordyne ones getting plugged all the time.
  42. Replies
    4
    Views
    1,005

    LENNOX MERIT SERIES

    Any feedback on the lennox merit series? i have been looking into a lower end line which still has a branded name on it i know its an air-flo unit,i really cant go with payne,goodman ect as most of...
  43. Thread: FIRST HEAT PUMP

    by splus
    Replies
    1
    Views
    618

    FIRST HEAT PUMP

    Go to help a good friend do a startup on a heatup system today and when i was configuring the stat there was no outdoor sensor which i know is an issue.There is a honeywell th8320u1008 there,after...
  44. Replies
    9
    Views
    1,715

    80% sidewall venting

    Was on a call yesterday for a water heater changeout and the homeowner asks me to change the filter a quick look in the attic and there is a 2 year old 80% forced air funace sidewall vented with...
  45. Replies
    6
    Views
    2,963

    I did take all the hoses off and made sure...

    I did take all the hoses off and made sure nothing was inside them,the furnace did cycle two times and then three days later i have the same pressure switch error.
  46. Replies
    6
    Views
    2,963

    Nordyne pressure switch ordeal

    I started a a/c install 3 days ago furnace is a nordyne kg7tc 2-stage that was installed 3 years ago with no issues.While do the low voltage wiring with new stat i deside to start furnace and check...
  47. Replies
    24
    Views
    2,996

    its a microchannel coil in the air handler?there...

    its a microchannel coil in the air handler?there is a charging chart on the cover of the outdoor unit use that.i have had some issues with charging these but when you get it right you will fine and...
  48. Replies
    3
    Views
    702

    i figured as much and its 7/8 after that to the...

    i figured as much and its 7/8 after that to the coil
  49. Replies
    3
    Views
    702

    Multiple size line set on unit

    Did a pm on a trane system older 4 ton txc coil no txv and a 3.5 ton r-410 4ttb outdoor.the line set was just under 50 feet at the coil its 7/8 suction but the last 8 feet to the condensing unit was...
  50. Replies
    14
    Views
    1,861

    Thanks for all the good info,i am running into...

    Thanks for all the good info,i am running into alot of systems that the airflow is either way to high or set on low speed and with days of 90 degrees an above a system not set up right on...
Results 1 to 50 of 504