Search:
Type: Posts; User: TRUETOTHEGAME
Search: Search took 0.02 seconds.
-
09-03-2010, 10:31 PM
Thread: Part time Alerton Work?
by TRUETOTHEGAME- Replies
- 3
- Views
- 591
WHEN AND WHERE
MY NAME IS WILL I HAVE FOUR YEARS IN THE TRADE I WOULD LOVE TO TAKE YOU UP ON YOUR OFFER TELL ME DETAILS AT WILL-MARI@HOTMAIL.COM
-
05-19-2010, 11:31 PM
- Replies
- 10
- Views
- 832
fan motor for extra condenser cooling
I have run across a unit that have the condenser fan motor constantly running.
My question is why and should I change it to the right way.
I"m not designer so usually I just leave it that way. ... -
05-16-2010, 07:14 PM
Thread: Capillary Tube
by TRUETOTHEGAME- Replies
- 53
- Views
- 6,904
I"ve experince the same results after just blow...
I"ve experince the same results after just blow the cap tubew that's there out
With nitrogen. I don't understand why almost the same results occur. You went even further and removed the oil.
My... -
05-16-2010, 11:45 AM
Thread: nitrogen and cap tube
by TRUETOTHEGAME- Replies
- 11
- Views
- 1,395
HEY THAT SOUNDS LIKE A PRETTY EASY WAYBTO CHANGE...
HEY THAT SOUNDS LIKE A PRETTY EASY WAYBTO CHANGE THE OIL. I'M GOING TO TRY THAT IDEA OUT THANKS.
-
05-15-2010, 08:51 AM
Thread: nitrogen and cap tube
by TRUETOTHEGAME- Replies
- 11
- Views
- 1,395
We are dealing with r409 r404 low temp...
We are dealing with r409 r404 low temp application. Victory m# fs-id-s7
The traulsern single door low temp units as well don't know model by heart
it usally happens when the unit is dirty for a... -
05-15-2010, 07:23 AM
Thread: nitrogen and cap tube
by TRUETOTHEGAME- Replies
- 11
- Views
- 1,395
nitrogen and cap tube
Recently I ran across a unit with a restriction. In the cap tube. Someone told me that you
Could blow it out with nitrogen and change the filter.
It works, but it got me in a tit for tat with... -
05-04-2010, 11:22 AM
Thread: cheap side job
by TRUETOTHEGAME- Replies
- 14
- Views
- 1,025
cheap side job
I did a side job for a resturant the other day. I want to know am I right
Or wrong. The own told me that he wanted me to use a old compressor
That he had on another unit. He didn't want to pay for... -
04-29-2010, 08:13 PM
Thread: is trade school better or college
by TRUETOTHEGAME- Replies
- 18
- Views
- 1,365
is trade school better or college
I went to apex in manhattan for about seven months. At times I feel as that if I would have went to college I would do better.
On the other hand it was all the time I could afford to lose with a... -
04-29-2010, 08:03 PM
Thread: Is it ok
by TRUETOTHEGAME- Replies
- 38
- Views
- 1,671
That is why I"m here so that I can stop eating...
That is why I"m here so that I can stop eating chicken I want steak.
-
04-28-2010, 07:41 PM
Thread: Is it ok
by TRUETOTHEGAME- Replies
- 38
- Views
- 1,671
If you add two feet to your suction line is it ok...
If you add two feet to your suction line is it ok to scale the same amount,
Of refrigerant in a self contained unit. Some of the units I work on are altered
A lot by these guy who know more than... -
04-27-2010, 03:52 PM
Thread: nitrogen pro's only
by TRUETOTHEGAME- Replies
- 32
- Views
- 1,812
That is a very scary thought I'm glad I will...
That is a very scary thought I'm glad I will never have to experince that. Learn that lesson thank you.
-
04-26-2010, 08:17 PM
Thread: Is it ok
by TRUETOTHEGAME- Replies
- 38
- Views
- 1,671
please don't get mad at me i'm treing to feed my...
please don't get mad at me i'm treing to feed my family that's all. Hey like i tell the costumer i am just a messenger
-
04-25-2010, 08:32 PM
Thread: stop n go
by TRUETOTHEGAME- Replies
- 33
- Views
- 1,174
i've heard of flowing nirtogen thru the piping....
i've heard of flowing nirtogen thru the piping. But i have never seen it performed can you inform me how to do this.
-
04-25-2010, 08:28 PM
Thread: stop n go
by TRUETOTHEGAME- Replies
- 33
- Views
- 1,174
mp 39 is 409 right thats what i used.
mp 39 is 409 right thats what i used.
-
04-25-2010, 08:20 PM
Thread: nitrogen pro's only
by TRUETOTHEGAME- Replies
- 32
- Views
- 1,812
i new 400 sounded crazy. 300 sounds like...
i new 400 sounded crazy. 300 sounds like something i could do and not be scared of
-
04-25-2010, 08:16 PM
Thread: Is it ok
by TRUETOTHEGAME- Replies
- 38
- Views
- 1,671
as of right know i have about 80 percent no call...
as of right know i have about 80 percent no call backs i'm trying to get that hundred. can you inform me on what is intresting please. i am ready to listen. every man craves wisdom.
-
04-25-2010, 08:13 PM
Thread: nitrogen pro's only
by TRUETOTHEGAME- Replies
- 32
- Views
- 1,812
nitrogen pro's only
I've had problems here and ther findin leaks. So i got advice from another mecanic who told me to charge 400 psig for a walkin. (nitrogen) is this ok or should i stick to the name plate and invest in...
-
04-25-2010, 08:06 PM
Thread: Is it ok
by TRUETOTHEGAME- Replies
- 38
- Views
- 1,671
The contract that my company have charges one set...
The contract that my company have charges one set amout for each gas. So when we write our invoice we write full charge no matter what. but on walk ins we just guess a number. My only wants to make...
-
04-23-2010, 04:27 PM
Thread: stop n go
by TRUETOTHEGAME- Replies
- 33
- Views
- 1,174
Guys the condenser was cleaned with foambrite....
Guys the condenser was cleaned with foambrite. The guys who trained me after school
Told me that was mombo jumbo subcooling is stupid now you guy are asking me about something I disreguarded 3... -
04-22-2010, 09:14 PM
Thread: stop n go
by TRUETOTHEGAME- Replies
- 33
- Views
- 1,174
stop n go
Today I was working on a traulsen m# rlt 1-123lut.
The unit has a half horse compressor with a cap tube feeding the evaporator single tube.
I was called in because the unit was not freezing.... -
04-21-2010, 06:11 PM
Thread: Is it ok
by TRUETOTHEGAME- Replies
- 38
- Views
- 1,671
weigh in
My company don't supply us with scales. the first person who trained me taught me that way. you charge it and walk away
-
04-21-2010, 06:02 PM
Thread: Walkin freezer icing up.
by TRUETOTHEGAME- Replies
- 14
- Views
- 2,546
did you check your site glass after you defrosted...
did you check your site glass after you defrosted the coil. this problem happen to me, i didn't check because the mecanic before me had more experiences. so i thought he would have checked some times...
-
04-16-2010, 10:56 PM
Thread: Is it ok
by TRUETOTHEGAME- Replies
- 38
- Views
- 1,671
The unit gave me afalse reading because I didnlt...
The unit gave me afalse reading because I didnlt look inside the coil it was clogged with debri. I chemically clean the and realized that I didn't put enough gas in the unit. I add gas and the unit...
-
04-13-2010, 08:00 PM
Thread: Is it ok
by TRUETOTHEGAME- Replies
- 38
- Views
- 1,671
Is it ok
i was working on a victory m# fs-rd-s7-ew reach in freezer today. I changed the capillary tube to the unit double feed half hourse power r404a refrigerant. the pressure to the high side was 150psig...
-
04-09-2010, 07:21 PM
- Replies
- 18
- Views
- 2,165
When i nstarted learning this trade, the most...
When i nstarted learning this trade, the most valuable peice of advice i was told was don't try to be an engineer in a day.
Results 1 to 25 of 30