  1. Replies
    2
    Views
    141

    sorry; went bact and found another plate with a...

    sorry; went bact and found another plate with a good model number. Some times things are so close you can't see them.
  2. Replies
    2
    Views
    141

    Heat Controller condenser

    Hi: Trying to size a couple of old heat controller condensers, first is 3237-7-18A & 3228-11-18A . Both are matched up with indoor evaps with no label on old natural draft furnaces. old furnace have...
  3. Replies
    13
    Views
    590

    Hi: the price for MO99 is 60% of cost of R-22 in...

    Hi: the price for MO99 is 60% of cost of R-22 in my area. The cylinder looks like 25#. Started to read a little online , seems you start with 85% of estimated charge. Have to check and see what oil...
  4. Replies
    13
    Views
    590

    MO99 drop in refrigerant?

    Hi: I see this refrigerant at my supplier. They say its popular for R22- units. I have a condenser change out next week and thinking about trying it. I'm buying a dry 3 ton ruud condenser and...
  5. Replies
    10
    Views
    480

    Yeh.. I did a couple water damaged ductwork...

    Yeh.. I did a couple water damaged ductwork reeplacement from evap overflowing. Had water filling up that black plastic wrap under home with gallons & gallons of water. When I open the plastic the...
  6. Replies
    10
    Views
    480

    I've done simular with the loose insulation,...

    I've done simular with the loose insulation, removed the garden hose off evap. drain etc. My other concern is the 5+8" sheetmetal chimney, the crappy gas burner.. etc. I was thinking a ruud...
  7. Replies
    10
    Views
    480

    HUD home furnace replacement

    Hi: I was trying to see about any pros or cons to replacing a miller counter flow furnace with something like a ruud 90+. The houses in this development are basiclly double wide trailers on a...
  8. Replies
    5
    Views
    292

    HUD home furnace replacement

    Hi: any thoughts pro or con to replacing a miller counterflow with something like a ruud 90+. Its a closet application & I could bring the return in the side from main hallway. A lot of the galv....
  9. Replies
    49
    Views
    2,610

    Thanks for your input, I held the fluke 902,...

    Thanks for your input, I held the fluke 902, looks like a simple unit I had it mine. I saw the UEI in a case, and looked on line- seems like there are a upper & lower display, wanted a single...
  10. Replies
    49
    Views
    2,610

    Choosing multi meter

    Hi: I'm trying find a replacement for my 20 year old Fluke 12 multi meter. It still works well, but confuses me when I try to ohm things out. Its has 4-5 setting for ohms. I also have a Amprob amp...
  11. Replies
    4
    Views
    246

    thanks for all the help...

    thanks for all the help...
  12. Replies
    4
    Views
    246

    Weather King model# BTU s question

    Hi: I'm trying to help a plumber friend size replacement equipment for his house. He has 2005 circa weather king evap # RCBA48826624. The condenser had the label melted off. He has had a addition to...
  13. Replies
    5
    Views
    353

    No, it not a miller. I think its spelled broan. ...

    No, it not a miller. I think its spelled broan. The guy bought this trailer of last winter. I'm wondering about blower, or maybe prior tenent dropped something down floor return register. I was...
  14. Replies
    5
    Views
    353

    I had good airflow. I went with a well...

    I had good airflow. I went with a well exsperinced mechanic. We opened and cleaned every thing inside. then started up , now after running for 15 min. 200/67 lb. for an hour, as we cleaned the pet...
  15. Replies
    5
    Views
    353

    Trailer package unit ice up

    Hi: Got a call for 12-15 year old 3 ton r-22 package unit with not cooling. Got there and all iced up. When back after thawed & got 200/50 lb. Took apart unit & found evap ok, condenser was with a...
  16. Replies
    6
    Views
    395

    Yeh: sometime I think everybody is on the same...

    Yeh: sometime I think everybody is on the same page as me, now to find I'm the only one on that page. condenser is TTRo24C100A0 evaporator coil is TXC031C4HPB1
  17. Replies
    6
    Views
    395

    Trane evaporator size?

    Hi: I'm try to find out the btu's on this coil, its about 20 years old. The lady has a 2 ton condensed thats shot and I was wondering the evap was 2.5 tons, so maybe I could increase it, Thanks.
  18. Replies
    3
    Views
    358

    Mini Split Help

    Hi:

    I have a customer with water damaged MUY-GE15NA condenser. He wants it replaced with same unit & keep indoor blower.
    I installed a couple of other brand units years ago, but never did much...
  19. Replies
    4
    Views
    590

    Thanks for the replys. Thought the seer was...

    Thanks for the replys.

    Thought the seer was higher. Its a shame the local heil dealer is blowing me off. I will try to contact another supplier w/ ICP equipment. Otherwise tell my customer I can...
  20. Replies
    4
    Views
    590

    Quiet Condenser..

    Hi: I'm trying to replace a guys condenser after Sandy storm damage. The existing Heil unit mo# H4A436GKD200.

    I used to be Heil dealer years ago, when a cut sheet listed almost everything. Now I...
  21. Replies
    7
    Views
    915

    Attic ductwork

    Hi: I'm trying to size a new upflow heater to existing non insulated sheetmetal system in attic. The old heater was removed from storm Sandy. I used a online calulater and got 49000 BTUS. There was...
  22. Replies
    9
    Views
    917

    SANDY- condenser under water

    Hi: working in atlanic city area. some condensers under water serveral inches to completly covered. At what point do you say the entire unit should be replaced. thanks.
  23. Replies
    4
    Views
    575

    WATER IN SERVICE HOSE

    Wondering how different tech's handle condenser service in rainy conditions. Had a customer today needing service, but the rain started coming down and unit had no filter dryer. Told them I would...
  24. Replies
    16
    Views
    1,381

    GOOD RECOVERY MACHINE

    Hi: I'm thinking of replacing my machine with Appion single. Only do small jobs- 2-4 tons. Supplier just started selling CPS tr21, says there super fast. A few hundred more. Anyone used the CSP...
  25. Replies
    67
    Views
    9,389

    staybrite for 20 years with no problems! Its what...

    staybrite for 20 years with no problems! Its what I like. My friend who works for a large company just switched for cost reasons.