Search:

Type: Posts; User: JJ57

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: R410A phase out?

    by JJ57
    Replies
    19
    Views
    3,242

    R32 is 1/2 of R410a in the First place, and it...

    R32 is 1/2 of R410a in the First place, and it has an A2L safety rating.

    This is very Similar to the new HFO 1234yf that is in some MVAC systems now.

    The R32 alone will probably yield some...
  2. Replies
    28
    Views
    2,500

    ANY yellow powder that is still there will start...

    ANY yellow powder that is still there will start to corrode things, like the crimps on the A/C lines, Electrical Wiring, Engine Pieces, Alternator, BRAKE LINES..... Just keep your head out for...
  3. Replies
    28
    Views
    2,500

    Let us know how it went, if the R/O does not say...

    Let us know how it went, if the R/O does not say anything about ABC power cleanup, it was not done right and you are in for nothing but problems from now on.
  4. Replies
    18
    Views
    5,700

    Interesting Invention. First off, they SHOWED...

    Interesting Invention.

    First off, they SHOWED THE WRONG VIDEO!!!! They should have showed this one:



    That is the ugly truth about Ionization Smoke Alarms, Burn Toast? Goes Right Off!!!! ...
  5. Replies
    28
    Views
    2,500

    Don't forget to get the Fire Extinguisher...

    Don't forget to get the Fire Extinguisher Recharged, or replaced ASAP!!!!! It is a one use deal!!!!

    Also, keep us posted on the status of the van.
  6. Replies
    28
    Views
    2,500

    WOW!!!!! Yea, you may have a problem or two. ...

    WOW!!!!! Yea, you may have a problem or two. WASH THE HELL OUT OF THAT ENGINE BAY!!!!!!
  7. Replies
    28
    Views
    2,500

    I know that this was a fire underhood the engine...

    I know that this was a fire underhood the engine compartment of the vehicle, but for PROPER ABC DRY CHEMICAL CLEANUP, the procedure above is the only sure and correct way to clean up the mess and...
  8. Replies
    28
    Views
    2,500

    Glad you are ok. What kind of fire extinguisher...

    Glad you are ok. What kind of fire extinguisher did you use? I hope it was a BC dry chemical (White). If it was an ABC (Yellow Powder) GET RID OF THE VAN!!!! The Mono-Ammonium Phosphate base of...
  9. Replies
    15
    Views
    1,823

    +++ On that one, somebody had to do something to...

    +++ On that one, somebody had to do something to one and make it work.


    In the places that I assist with, we rebuild Magic Pack, NCP, PATCO, Magic Chef...... ETC all the time. For Apartments...
  10. Replies
    19
    Views
    3,540

    21 pounds?!?!?! WOW!!!! Good thing for the HP...

    21 pounds?!?!?! WOW!!!! Good thing for the HP trip off or else goodbye system.
  11. Replies
    23
    Views
    2,069

    Ahhhhh..... Yes, the Photoelectric Duct smoke...

    Ahhhhh..... Yes, the Photoelectric Duct smoke detector. Great unit, but it does require maintenance from time to time. The tripping is caused by dirt/dust inside the unit, but it being 13 years...
  12. Replies
    68
    Views
    6,077

    HC's can be used safely with proper precautions...

    HC's can be used safely with proper precautions taken. There are already many products that come with HC's, But all are equipped with warning labels and most small appliances (referigrators,...
  13. Replies
    68
    Views
    6,077

    So.......If i went to a wholesaler what...

    So.......If i went to a wholesaler what certification would I need to show to buy a 30 pound tank of R134a?

    And online, or at anywhere else, do I need to license to purchase any Hydrocarbon...
  14. Replies
    68
    Views
    6,077

    Oh Really? And I'm the ignorant one? ...

    Oh Really?



    And I'm the ignorant one? :rolleyes:

    You can only hope and pray that you will never need anyone of us at anytime.....it is quite obvious that you have no idea of what those...
  15. Replies
    68
    Views
    6,077

    Not a bad idea to cover your a$$ in case there is...

    Not a bad idea to cover your a$$ in case there is a HC in a system.





    Sweet!!!!! Just make sure that you are professional or else you don't count!! :pileon:

    Lets crack out the...
  16. Replies
    68
    Views
    6,077

    R600a is flammable, and what they are concerned...

    R600a is flammable, and what they are concerned with is the amount of gas.....along with WHERE THE LEAK WOULD HAPPEN, and how much how fast. So if a pinhole leak developed in a micro-channel...
  17. Replies
    68
    Views
    6,077

    Nobody is sitting here advocating "The hell with...

    Nobody is sitting here advocating "The hell with the laws" and to go and charge up everyones system with whatever. If you want to do an experiment, that is your choice, just don't do it to a...
  18. Replies
    68
    Views
    6,077

    WHAT THE HELL IS THAT SUPPOSED TO MEAN? DON'T...

    WHAT THE HELL IS THAT SUPPOSED TO MEAN? DON'T EVEN GO THERE. PA has over 85% of firefighters that are VOLUNTEER!!!! THE NEXT TIME ONE OF YOUR LOVED ONES OR YOURSELF HAS A HOUSE FIRE, OR GETS INTO...
  19. Replies
    68
    Views
    6,077

    Oh boy...Here we go again. First off,...

    Oh boy...Here we go again. First off, Hydrocarbons are not unsafe....... UNLESS THEY ARE NOT DEALT WITH PROPERLY.......THEN YOU HAVE AN ISSUE. As a lot of you know, I do the HVAC trade part time,...
  20. Thread: Who's on call

    by JJ57
    Replies
    34
    Views
    2,426

    I'm not on call for the HVAC stuff, but if you...

    I'm not on call for the HVAC stuff, but if you check my profile pic, I am on call for something else.

    From your Friendly Fire Department........Fireworks can be fun, if used...
  21. Replies
    86
    Views
    15,341

    Oh Trust me........We have done that on several...

    Oh Trust me........We have done that on several occasions. On the older chassis, they are stripped down, repainted with rust proofing primer, and then new compressors, either reman or new coils, and...
  22. Replies
    86
    Views
    15,341

    Now that I agree with It's was funny when I...

    Now that I agree with

    It's was funny when I got to "Have Fun" with the nu calgon rep. He was going on and on about all the benefits, and I just jumped in and stated that we used it to prevent...
  23. Replies
    3
    Views
    486

    Time for some A/C Renew!!!!! LOL!!!!! I had...

    Time for some A/C Renew!!!!! LOL!!!!! I had too!
  24. Replies
    86
    Views
    15,341

    And just for the record, AHRI are not "God" and...

    And just for the record, AHRI are not "God" and other issues can come up with ANY situation:
    ...
  25. Replies
    86
    Views
    15,341

    Trust me, it's no upsell, it is DEFINITELY a hope...

    Trust me, it's no upsell, it is DEFINITELY a hope to avoid callbacks. In the Magic Pack PATC units, if you ever worked on them you know that they can be a pain in the a$$ to service. It just is a...
  26. Replies
    86
    Views
    15,341

    No, I totally agree that using A/C renew from the...

    No, I totally agree that using A/C renew from the factory to get better SEER ratings would be a crock.

    And like I stated before, EACH SYSTEM IS DIFFERENT!!!

    I have seen older R22 units have...
  27. Replies
    86
    Views
    15,341

    That is a very good point. Or you try the...

    That is a very good point.

    Or you try the product on your units and find out that is does work........or does not.

    The one claim that I do not agree with is that just put in in run it for...
  28. Replies
    86
    Views
    15,341

    A few things I noticed is in the R22 systems, the...

    A few things I noticed is in the R22 systems, the cans worked great!! In the R410a systems, we used their injector tool, as we are only using 2 ounces for Magic Packs VS 4 for regular. The liquid...
  29. Replies
    86
    Views
    15,341

    Zerol Ice became A/C Renew, a product of nu...

    Zerol Ice became A/C Renew, a product of nu calgon. One of the changes was due to the pressurized cans originally had R22 as a carrier gas for the can. A simple connection of the suction port with...
  30. Replies
    2
    Views
    606

    Yea.....That could be a problem. Or when you do...

    Yea.....That could be a problem. Or when you do your A/C work dealing with 90% Magic Pak PATC type units, from Condos, Apts, student housing, 55+ communities...... Watching the look of the...
  31. Replies
    109
    Views
    6,747

    Just saw your Update post, Dual means having a...

    Just saw your Update post, Dual means having a front and rear factory system, not just cooling the front and back. Those Temps Look Great, something could have worked it's way loose and is now in...
  32. Replies
    109
    Views
    6,747

    For my main Job, I am a network engineer, and we...

    For my main Job, I am a network engineer, and we have several 3500 GMC Savana 3500 EXT 6.6 Diesels, in a cargo version. They are equipped with FACTORY REAR A/C as we don't want the computer stuff...
  33. Replies
    2
    Views
    782

    You may also want to take a look here: ...

    You may also want to take a look here:

    http://www.nucalgon.com/products/oils/a-c-re-new

    Now a lot of people thought of this as another "Snake Oil" product, HOWEVER, with the rash of those bad...
  34. Replies
    2
    Views
    782

    The name, it's basically the same product just...

    The name, it's basically the same product just re-named. But keep in mind, the older pressurized cans of Zerol Ice contained R22 as a carrier gas to get the product into the system. The newer...
  35. Replies
    10
    Views
    1,590

    The R410a one was larger and that unit still had...

    The R410a one was larger and that unit still had power and was running when the roof came down in the HVAC closet, and a few minutes later... WOOSH!!!!!!

    After the propane tank Blew up the HVAC...
  36. Replies
    10
    Views
    1,590

    That is correct, it was the oil that was burning,...

    That is correct, it was the oil that was burning, not the R22 or R410a but it was pressurized and atomoized, that is what did it.

    It was still a sight to see, a 5 foot flame coming out for 20-30...
  37. Replies
    10
    Views
    1,590

    The insurance thing is what has me..... That...

    The insurance thing is what has me..... That would be a huge breaking point.

    Never really thought about that.

    Points taken.

    And yea, don't think when we were close to some of the...
  38. Thinking about it, the insurance thing is what...

    Thinking about it, the insurance thing is what has me...... Would they pay?

    That is a reason alone to not do it.

    Point Taken.
  39. It was a "U" shaped building and the Fire was...

    It was a "U" shaped building and the Fire was jumping, Got a first hand look at what R22 or R410a will do when enough heat gets to them and it reaches that point..... FLASH POINT......As soon as...
  40. All the units have been labeled, with no personal...

    All the units have been labeled, with no personal ID info on the tag. Just a Generic Sticker Stating the unit was converted to a HC gas and to observe all safety measures and service/handling...
  41. Replies
    10
    Views
    1,590

    When all hell breaks loose

    Some of you know that I am also a Volunteer Fireman, well Friday night all hell broke loose:
    ...
  42. Considering what just happened, and the response...

    Considering what just happened, and the response that we ran, I am telling him that as of next week, we are pulling out ALL of the HC's and recharging it with R22.

    I will post in the General...
  43. Ok, have thought this over, from this point...

    Ok, have thought this over, from this point forward, we are putting a hold on all HC charges. All the units will be inspected and tags will be in place.

    We will inform the apartment management...
  44. http://www.epa.gov/ozone/snap/download/MailFOV_Env...

    http://www.epa.gov/ozone/snap/download/MailFOV_EnviroSafe_06112013.pdf

    Again thanks for everyones input, I found the Notice of Enforcement and actions to be taken.

    Notice it only covers...
  45. HOW DID WE ALL MISS THIS: ...

    HOW DID WE ALL MISS THIS:


    http://www.pjstar.com/news/x1037524867/Explosion-at-Enviro-Safe-in-Pekin-reportedly-injures-4-people#thecomments

    This changes everything. I didn't blow up, but they...
  46. Wow, I did not know about the enforcement...

    Wow, I did not know about the enforcement actions. That is good to know.

    Yes, all of the units are labeled, and with this new enforcement actions, I think I will step away for a while and lets...
  47. Actually HC's can be used for MO99, 407C, and 2nd...

    Actually HC's can be used for MO99, 407C, and 2nd Gen replacements. Which is what was happening. They went with NU-22, and were not happy with the performance, so they began to install the HC's. ...
  48. Cooling Chassis Replacements.... And I didn't blow up!!!!

    As some of you know, in working part time with a family memeber at some apartment complexes, I have used ES22a and ES502a and some air enhancer additive with excellent results.

    We have a few new...
  49. I do this too with a family member part time. ...

    I do this too with a family member part time.

    "Beer Can Cold" is how you charge the MAGIC PAK system.

    Superheat and Subcooling? WTF does that mean?

    It's an apartment complex. I only...
  50. Replies
    27
    Views
    4,861

    After considering all of the factors involved,...

    After considering all of the factors involved, the 3 ton 2 stage with the VS blower would be fine.
Results 1 to 50 of 197