    PXC200-E.D is a DESIGO part. You will need to be...

    PXC200-E.D is a DESIGO part.
    You will need to be in a country where DESIGO is supported.
    You are correct, this is just the controller. You will also need Power Module(s) and TX-I/O modules. These...
  2. Replies
    8
    Views
    1,009

    I have a PXC Compact running BACnet 3.1. I had...

    I have a PXC Compact running BACnet 3.1.
    I had to use the encoded naming convention to command some Binary Outputs in a different manufacturer's panel.
    For example,
    To turn on a binary output...
  3. Replies
    8
    Views
    1,009

    What kind of controllers are being used?

    What kind of controllers are being used?
  4. Replies
    12
    Views
    1,929

    The only problems that you could really take care...

    The only problems that you could really take care of on an Open Processor or an MEC would be configuration or firmware issues.
    You could troubleshoot down to the board level, depending on the...
  5. Replies
    21
    Views
    4,247

    NO. The older MEC Expansion Modules did not have...

    NO. The older MEC Expansion Modules did not have an isolated trunk, and did not have a baud rate switch. They were designed to be used specifically on the MEC's expansion port in a 'same room'...
  6. Replies
    21
    Views
    4,247

    What version of Field Panel firmware do you have,...

    What version of Field Panel firmware do you have, and what version of Insight?
  7. Replies
    29
    Views
    4,299

    UCIS was the 'CIS' used to talk to the UC.

    UCIS was the 'CIS' used to talk to the UC.
  8. Replies
    29
    Views
    4,299

    run-time error R6009 - not enough space for...

    run-time error R6009
    - not enough space for environment


    The error seems to be caused by the different DOS command interpreter used by Windows XP (cmd.exe vs. command.exe).

    I was able to use...
  9. Thread: PPCL Question

    by lost0ne
    Replies
    38
    Views
    4,902

    Seriously?

    Seriously?
  10. Replies
    68
    Views
    5,625

    Open: the ability to mix and match components of...

    Open: the ability to mix and match components of a particular layer between different manufacturers.

    If a system supports the ability to utilize different manufactures' equipment at the different...
  11. Thread: Mstp Wiring

    by lost0ne
    Replies
    4
    Views
    1,381

    Some of the proprietary RS-485 based protocols...

    Some of the proprietary RS-485 based protocols have been based on a two wire concept. The RS-485 is a differential signal which is presented on two wires. Internally the communication power supply is...
  12. Replies
    14
    Views
    3,003

    There is the DEFINE statement which helps...

    There is the DEFINE statement which helps facilitate the use of virtual points for testing. Use general point names in your PPCL and define some virtual points for testing.
    Place the DEFINES...
  13. Replies
    4
    Views
    1,290

    The APOGEE PXC Compact Controllers are available...

    The APOGEE PXC Compact Controllers are available in a Native Bacnet Version.
    These will work with APOGEE Insight. You might have to upgrade to 3.9 or 3.91, and include the BACnet software.
    The HMI...
  14. Replies
    4
    Views
    1,290

    PXC22-E.D are DESIGO units. You will need...

    PXC22-E.D are DESIGO units.
    You will need something to configure them with; DTS, X-Works, etc.
    I know that APOGEE can see them as third party devices, but I haven't really done anything beyond...
  15. Replies
    37
    Views
    13,544

    The PXC Compact Controller is a global product,...

    The PXC Compact Controller is a global product, used with both APOGEE (mostly US) and DESIGO (mostly Europe).

    It is available as a 16 point or 24 point unit (US) and as a 12 point or 22 point unit...
  16. Replies
    8
    Views
    2,456

    If you are talking about using the Ethernet ALN...

    If you are talking about using the Ethernet ALN then you are talking about using a proprietary protocol.
    The PXC Modular has one Ethernet port. Depending upon which Modular you get it either talks...
  17. Replies
    4
    Views
    1,091

    There are seperate owner's manuals. I'll send you...

    There are seperate owner's manuals. I'll send you one for the Compact.
    I don't think that there are specific user's manuals; they are both covered in the APOGEE Field Panel User's manual.
    Will this...
  18. Replies
    4
    Views
    1,091

    Compact or Modular?

    Compact or Modular?
  19. Replies
    7
    Views
    1,336

    The MBC will be supported for many years. Even...

    The MBC will be supported for many years. Even after a product is no longer offered for new sales it is typically supported for at least 7 years.

    The PXC Modular Controller (A.K.A. Modular, or...
  20. Replies
    11
    Views
    19,046

    Here is what I found for the display module.

    Here is what I found for the display module.
  21. Replies
    11
    Views
    19,046

    I'll check.

    I'll check.
  22. Replies
    11
    Views
    19,046

    Landis & Gyr PolyGyr controllers

    Here are some of the original data sheets.
  23. Replies
    11
    Views
    19,046

    I remember those (and the brownish plastic room...

    I remember those (and the brownish plastic room sensors).
    I'll check and see if I have any documentation at work tomorrow.
  24. Replies
    12
    Views
    2,125

    I am not very familar with Datamate but the...

    I am not very familar with Datamate but the user's manual saya that it should be able to use the .P2 file.
    What version do you have?
  25. Replies
    3
    Views
    1,124

    There are Integration drivers that can be loaded...

    There are Integration drivers that can be loaded in some APOGEE controllers to support MSTP LANs.

    There are also native BACnet versions of Siemens Controllers.

    The Insight Software has both a...
  26. Replies
    11
    Views
    1,213

    If it is originally set at "YES" did you try to...

    If it is originally set at "YES" did you try to command it to "NO"?
  27. Replies
    15
    Views
    2,038

    Perhaps you could export the program and include...

    Perhaps you could export the program and include it as an attachment later. Or even the .P2 file from the job's directory.
  28. Replies
    15
    Views
    2,038

    You are correct - the 'ET' means that the line is...

    You are correct - the 'ET' means that the line is enabled and that it has been scanned.
  29. Replies
    15
    Views
    2,038

    Here is the problem (I missed it until...

    Here is the problem (I missed it until shifferbrains pointed it out) - I believe that the line should read IF ("SPACE TEMP".GT.82.0)THEN ON(FLAG) (no word "IS")

    This assumes that you have a newer...
  30. Replies
    6
    Views
    989

    I am not sure that I understand how you hooked up...

    I am not sure that I understand how you hooked up your meter to take a measurement.
    It sounds as though you had both meter leads connected to the transducer. You should have the Positve meter lead...
  31. Replies
    15
    Views
    2,038

    Check to see that the line is enabled. Check to...

    Check to see that the line is enabled.
    Check to see that FLAG is a valid point that has a priority of NONE.
    Check to see that this line of code is being executed by using the Trace function.

    I...
  32. Replies
    17
    Views
    1,738

    You are correct. The thermistor is read by...

    You are correct.
    The thermistor is read by impressing a voltage across it or passing a constant current through it (better way). Connecting a thermistor to two controllers at the same time may...
  33. Replies
    8
    Views
    1,485

    You will probably want to provide a signal common...

    You will probably want to provide a signal common from the controller to the actuator. Usually twisted pair is used for the signal and it's return. Also,you must be concious of any other externally...
  34. Replies
    29
    Views
    8,006

    The System 600 / APOGEE deals with 2 basic point...

    The System 600 / APOGEE deals with 2 basic point types:
    Physical - points that have a termination.
    Virtual - points have no physical termination; they exist in memory only


    I...
  35. Replies
    3
    Views
    1,356

    I meant to say that it should beset to Bacnet/IP...

    I meant to say that it should beset to Bacnet/IP and not Ethernet.
  36. Replies
    3
    Views
    1,356

    Check your property settings for the Cimetrics...

    Check your property settings for the Cimetrics BACstac as found in the Network Connections Properties window. Is the Physical Port Protocol set to Bacnet/IP (not ethernet)?
  37. Replies
    8
    Views
    1,476

    Can you tell a little more about the sensor, or...

    Can you tell a little more about the sensor, or what kind of Field Panel it is connected to?
    If the sensor is not a 4-20mA unit (resistive element only) there are a couple of different elements...
  38. Replies
    16
    Views
    2,636

    Check the setting under the BLN's properties and...

    Check the setting under the BLN's properties and make sure that the specified Device ID range, Mfg ID and Network number are appropriate.

    Do you have any BACNET devices communicating?
  39. Replies
    16
    Views
    2,636

    If you have an Insight front end you can upload...

    If you have an Insight front end you can upload the point database and PPCL from the UC, make modifications, and download back to the UC. Caution: when something is downloaded to a UC everything in...
  40. Replies
    25
    Views
    3,774

    With all of the Field Panels showing failed it...

    With all of the Field Panels showing failed it appears that the Insight is not connected. Looking at the Trunk Interface the DTR light should come on when the PC opens it's com port. The PMD Rx and...
  41. Thread: Room Sensors

    by lost0ne
    Replies
    6
    Views
    1,258

    I believe that the 2000 series is also available...

    I believe that the 2000 series is also available for the MBC or UC.
    These are base on a 1000 ohm (TC375) sensing element.
    The PXC supports this.
    There are also versions with 4-20mA outputs, which...
  42. Replies
    18
    Views
    2,013

    The AO-P is available as both a Point Module...

    The AO-P is available as both a Point Module (MBC) and as an external unit (cast metal housing).
  43. Replies
    3
    Views
    7,251

    UL-864

    You are correct.
    UL-864 is for a system.
    The individual parts must be approved for use in the system.
  44. Replies
    3
    Views
    7,251

    UUKL Smoke Control (UL-864)

    If your products are approved for UL-864 Smoke Control then there is a requirement for this in your marketplace.

    The standard Energy Management (UL-916)rating is primarily concerned with product...