Search:

Type: Posts; User: ahc&r

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Thread: Tools

    by ahc&r
    Replies
    36
    Views
    6,001

    dl187t multimeter c to f

    dl187t multimeter c to f
  2. Thread: Tools

    by ahc&r
    Replies
    36
    Views
    6,001

    can you ntell me how to change celsius to...

    can you ntell me how to change celsius to farienheit on my DL 187t meter
  3. Replies
    8
    Views
    1,722

    agree with tj, it's broke

    agree with tj, it's broke
  4. Replies
    27
    Views
    3,870

    A cap of bleach once a week will really limit...

    A cap of bleach once a week will really limit that buildup
  5. Replies
    48
    Views
    7,670

    spend the extra money for a higher quality.

    spend the extra money for a higher quality.
  6. Thread: cooking

    by ahc&r
    Replies
    18
    Views
    1,719

    thank you for the hel[p, traps took care of the...

    thank you for the hel[p, traps took care of the problems
  7. Could have used one last week

    Could have used one last week
  8. Replies
    15
    Views
    2,318

    My ex got mine

    My ex got mine
  9. Replies
    58
    Views
    6,206

    looking forward to ascj's questions, I had...

    looking forward to ascj's questions, I had issues with dirty pilot burner at ignition source and igniter points
  10. Replies
    13
    Views
    4,837

    How bout heavy smoke and less than 85

    How bout heavy smoke and less than 85
  11. Replies
    75
    Views
    5,275

    This is not a bin or proxi switch. A mechnical...

    This is not a bin or proxi switch. A mechnical one behind the water valve
  12. Replies
    75
    Views
    5,275

    I got no response on the micro switch, spoke you...

    I got no response on the micro switch, spoke you folks think it's silly. Also called an interlock switch. If not set right it does stange things
  13. Replies
    75
    Views
    5,275

    Is there a microswitch behind the water/clean...

    Is there a microswitch behind the water/clean valve on this unit?
  14. Get second opinion, attic units often are too...

    Get second opinion, attic units often are too short on supply also. Check TD. [18-22]
  15. Replies
    21
    Views
    1,958

    I would not quote over the phone, can't what all...

    I would not quote over the phone, can't what all it takes in labor. 2 hours could turn into 6 real easy not to mention unforseens.
  16. Thread: cooking

    by ahc&r
    Replies
    18
    Views
    1,719

    I believe Ur correct, Think they can be cleaned?...

    I believe Ur correct, Think they can be cleaned? they are not cheap, but easy to replace
  17. Replies
    122
    Views
    5,548

    Thats how I tie in the equalizer line, off the...

    Thats how I tie in the equalizer line, off the existing line
  18. Thread: door gaskets

    by ahc&r
    Replies
    16
    Views
    1,298

    A dead blow hammer will crack plastic along the...

    A dead blow hammer will crack plastic along the edge, especialy on a freezer door. Heat gun will also smooth out wrinkles
  19. Replies
    3
    Views
    1,645

    this could get real dangerous real fast

    this could get real dangerous real fast
  20. Thread: door gaskets

    by ahc&r
    Replies
    16
    Views
    1,298

    heat gun, careful thogh, it will melt

    heat gun, careful thogh, it will melt
  21. Thread: YEARLY SALARY

    by ahc&r
    Replies
    40
    Views
    4,590

    Thats about right, plus perks

    Thats about right, plus perks
  22. Replies
    32
    Views
    3,735

    Didn't see a hi press reading, since u cleaned a...

    Didn't see a hi press reading, since u cleaned a plugged condenser the system may be under or over charged and or look at the headmaster. does the outdoor fans shut off. Imo Ur just running out of...
  23. Thread: YEARLY SALARY

    by ahc&r
    Replies
    40
    Views
    4,590

    60 in 1998 in IA

    60 in 1998 in IA
  24. Replies
    122
    Views
    5,548

    the bulb doesn't get wrapped till after install....

    the bulb doesn't get wrapped till after install. bulb should be removed during brazing
  25. Thread: cooking

    by ahc&r
    Replies
    18
    Views
    1,719

    Steamer works great in on position. yes on the...

    Steamer works great in on position. yes on the jmet stream. yes 1.5" black iron though. 3 90's and less than 4' run.
    steam vent through drain when in stanby. Going to have to find a parts break...
Results 1 to 25 of 76