  1. Do you think it will use significantly more fuel...

    Do you think it will use significantly more fuel now that it runs an extra minute every time the burner kicks on than it did last year when the fan started after 50 seconds of burner run time?
  2. yes, very close to furnace. A direct line at...

    yes, very close to furnace. A direct line at this register to the furnace (not through the plenum) and about 10 to 15 linear feet of duct.
  3. When it first comes out of the register it is the...

    When it first comes out of the register it is the latent air inside the ducts and is 70 degrees. within a 10 or 15 seconds it's up to 75, within a minute its up to 85 within a few minutes it peaks...
  4. okay, I'll do that. I assume measure the temp at...

    okay, I'll do that. I assume measure the temp at the closest register to the furnace and also at the return. I suspect that the initial temp will be on the cool side since the ducts would have to...
  5. New Control board, different delay settings

    Over the summer, the control board to my AC/furnace failed and was replaced. The heating season is just about to begin and I noticed that the delay between the blower and burner is slightly...
  6. Replies
    28
    Views
    1,550

    I agree, I will be going back to the original...

    I agree, I will be going back to the original company that serviced the burner properly. However, my real internal debate is whether to do that now, or simply wait it out until next year. In other...
  7. Replies
    28
    Views
    1,550

    I understand. It is pretty frustrating though. ...

    I understand. It is pretty frustrating though. In fact, if i just didn't pay any attention in the first place, i wouldn't even know anything is wrong.

    This company has been in buisiness for 25...
  8. Replies
    28
    Views
    1,550

    It did it a bit at the end of the year. But it...

    It did it a bit at the end of the year. But it mainly ran great.

    Should I not trust this company anymore? If I call anyone else to look at the burner, it will cost $$.

    For what it is...
  9. Replies
    28
    Views
    1,550

    What do you make of this: Damper is still...

    What do you make of this:

    Damper is still banging around on initial start up and progressively gets better over a period of minutes. Once the burner has been running 4 to 5 minutes, the damper...
  10. Replies
    14
    Views
    1,419

    Thank you! This is exactly the info I was...

    Thank you! This is exactly the info I was looking for.

    Another follow up, if I may.......

    Would the basement need a separate "zone"? Or would it just receive heat when the upstairs t-stat...
  11. Replies
    14
    Views
    1,419

    The current duct system is probably undersized. ...

    The current duct system is probably undersized. The main trunk is 16 by 6 and the individual ducts coming off are 5-inch diameter. The whole duct system would get replaced in one shot with the...
  12. Replies
    14
    Views
    1,419

    basement remodel

    If I was to finish my full basement, could I use my existing oil furnace to heat it, if new returns and supplies were run in the basement?

    My furnace is currently way oversized for the house. It...
  13. Replies
    28
    Views
    1,550

    Well, the tech came out to the house yesterday...

    Well, the tech came out to the house yesterday afternoon. Unfortunately, I could not be there, my wife was there. I left a note describing the issue.

    My wife told me the tech was there for 10...
  14. Replies
    28
    Views
    1,550

    Inside the furnace, there is a chart which lists...

    Inside the furnace, there is a chart which lists .75gph as standard and also lists .65 and .5 as alternative nozzle sizes.

    That is the furnace though, i don't know if the burner is able to run on...
  15. Replies
    28
    Views
    1,550

    just made a service appt. they cant make it...

    just made a service appt.

    they cant make it to my house until next tuesday though.

    I told them that the burner was running rough, damper banging back and forth, etc..

    Is this normal?
    ...
  16. Replies
    28
    Views
    1,550

    The ductwork in my home is very small. My...

    The ductwork in my home is very small. My feeling is that even with the "high" speed on the fan, the ductwork is limiting the air volume and speed. It is a small 1 story home w/basement (unheated,...
  17. Replies
    28
    Views
    1,550

    I measured tonight. I was out of house and heat...

    I measured tonight. I was out of house and heat was off, so when I turned it back on, it got to run for a good while. I also have the return directly above the furnace and the nearest register is...
  18. Replies
    28
    Views
    1,550

    Thanks for the advice. I will call them back. ...

    Thanks for the advice. I will call them back.

    FYI, I looked inside the furnace and for the 0.75gph nozzle, it lists high or med-high as acceptable fan speeds. Temp rise is 55 to 85 degrees.
    ...
  19. Replies
    28
    Views
    1,550

    I was half thinking that myself. But which...

    I was half thinking that myself. But which company? The same one that I had put in the smaller nozzle?

    Also, does the fan speed have to be put back to high? The current fan speed is med-high...
  20. Replies
    28
    Views
    1,550

    he told me that he adjusted the damper using...

    he told me that he adjusted the damper using instruments. My question though is which of the three options should I do? Call back same company? Call new company and pay? Or just wait till next...
  21. Replies
    28
    Views
    1,550

    Burner advice sought....

    Background: (I will try to be brief)

    September this year, called HVAC company to downfire Carrier oil-fired hot air furnace with Beckett burner. Was a 0.75gph and now is a .65gph. Reason for...
  22. Replies
    20
    Views
    975

    no, he didn't say anything about heat exchanger. ...

    no, he didn't say anything about heat exchanger. He was just here about a month ago for an annual service/cleaning. So I assume if the heat exchanger was a problem, he would have said something?
  23. Replies
    20
    Views
    975

    OK, that kind of jives with what he told me. He...

    OK, that kind of jives with what he told me. He said that when it got colder, I would likely see the damper open up a bit.

    At any rate, furnace seems to be running great, It had always...
  24. Replies
    20
    Views
    975

    I don't know what it was unfortunately. He told...

    I don't know what it was unfortunately. He told me that I had a "good" draft and also that he could tell that my chimney was working very well.

    Anything to offer regarding my question listed just...
  25. Replies
    20
    Views
    975

    still curious.....the barometric damper is set...

    still curious.....the barometric damper is set toward the high end now, something like 0.08 and when the burner was running, it doesn't open at all.

    Tech told me that was OK and that during winter...