  1. Replies
    6
    Views
    405

    its level, has a ez trap on it. I checked it...

    its level, has a ez trap on it. I checked it yesterday morning. It was dry but not completely. Going to look into the blowoff kit.
  2. Replies
    5
    Views
    302

    Thats one of those "Apartment" units isn't it?

    Thats one of those "Apartment" units isn't it?
  3. Replies
    6
    Views
    405

    Water being pulled off the coil

    https://www.youtube.com/watch?v=ilSIUvacroo
    One from today. Water being pulled off the coil. Laid my phone on top of the A coil, horizontal unit. The black is the drain pan. Unit in an attic. ...
  4. Replies
    6
    Views
    286

    Duct liner man.... Everything in the attic...

    Duct liner man....


    Everything in the attic got wrapped with r13 insulation as well as the duct liner. So the r8 flex was basically r25 plus or minus.
  5. Replies
    7
    Views
    335

    I use stabrite for 99% of our work. Clean your...

    I use stabrite for 99% of our work. Clean your fittings, liquid flux, good to go. We never have leaks. Anyone still lugging around oxy/act setup is doing it the hard way, don't forget your...
  6. Replies
    7
    Views
    335

    Quick changeout from yesterday.

    New furnace coil and ac. Added media filter. Wanted to redo return drop but would have been more of a pita than it was worth. Has another RA trunk in the back of the unit.

    Couldn't get an...
  7. Replies
    6
    Views
    286

    Simple new house.

    I guess it was simple, got in after the plumber and hand to run all my duct around his stuff. No room left for returns in the crawl, had to run in the attic.

    Little 2 ton 60k 2 stage system.
    ...
  8. Replies
    9
    Views
    608

    Nice looking work man!

    Nice looking work man!
  9. What did they do to prevent floods next time? ...

    What did they do to prevent floods next time?
    Reason for going back with 80%?
    Media filters....
  10. Replies
    14
    Views
    1,387

    furnace is 1/2 cpvc slipped into 3/4 pvc. There...

    furnace is 1/2 cpvc slipped into 3/4 pvc. There is an air space around it.
  11. Replies
    14
    Views
    1,387

    no idea what a firomatic is?

    no idea what a firomatic is?
  12. Replies
    10
    Views
    1,190

    We occasionally hang one off the house. Usually...

    We occasionally hang one off the house. Usually try to get builder to either pour a pad, which is ideal, or build a deck as you have shown. If not I specify backfilling where ac is to be done with...
  13. Replies
    14
    Views
    1,387

    Depends. Some may just have one big return in the...

    Depends. Some may just have one big return in the middle of the house, this had one big one in the living room and 8" flex ran to each bedroom.
    Typical new construction, I run everything in the...
  14. Replies
    14
    Views
    1,387

    One from this week

    Basic 15 seer ac and 2 stage variable furnace. Took out an 80% tempstar and villager ac. Easy peasy. Done by 3.

    I left the old canvas connector at the ceiling. The plug, well he had one on...
  15. Replies
    14
    Views
    2,080

    Case and all. insulation in the other case...

    Case and all. insulation in the other case pretty much seals it up all the way around. I slipped some foam tape on one, as well as on the bottom of the coil case. A little more on the door and no...
  16. Replies
    14
    Views
    2,080

    2nd one had to use a threaded 9- right out off...

    2nd one had to use a threaded 9- right out off the coil. across top of furnace, around to the back and across the back into the pump.
  17. Replies
    4
    Views
    875

    Nice, I put a base under anything 3 tons or more,...

    Nice, I put a base under anything 3 tons or more, pull from side and bottom. Only thing I don't like is the flues out the top, can't they come out the side?
  18. Replies
    8
    Views
    1,542

    and those pressure switches are sensitive!

    and those pressure switches are sensitive!
  19. Replies
    14
    Views
    2,080

    I've been hacking things up across town

    Done a few coil and ac swaps lately.

    https://c4.staticflickr.com/4/3691/18685310079_f3c2e5cb09_h.jpg

    https://c2.staticflickr.com/6/5514/18657538890_f99f3d387d_h.jpg

    Just slip them in case...
  20. Replies
    8
    Views
    1,542

    Looks good, drain should have been done different...

    Looks good, drain should have been done different but other than that, top notch! Supposed to be an air gap between coil drain and furnace drain.
  21. Thread: XV20i

    by jimmyed
    Replies
    22
    Views
    1,765

    :) My only complaint would be the eac. Can't...

    :) My only complaint would be the eac. Can't believe anyone still sells them. People around here always threw the guts out and put in a regular filter. I haven't been to one house with an eac...
  22. Replies
    6
    Views
    1,376

    pipe my drain like how? its open, do them all...

    pipe my drain like how? its open, do them all this way and haven't had a problem yet. 1/2" cpvc slid inside 3/4 sh120
    open tee is so that in the event that the trap clogs up in the winter i don't...
  23. Replies
    6
    Views
    1,376

    Another easy one

    https://c1.staticflickr.com/1/271/17737838604_8ee4b8a802_h.jpg

    https://c4.staticflickr.com/8/7733/18334023486_6ff2e56eb9_h.jpg

    https://c4.staticflickr.com/8/7753/18174291129_9325e82942_h.jpg
    ...
  24. Replies
    11
    Views
    1,464

    Another low boy gone.

    https://c4.staticflickr.com/8/7754/18253362776_1b84acea36_h.jpg
    https://c4.staticflickr.com/8/7752/18093585259_0fecc8b326_h.jpg

    Flues look like ass.. Not much else I could do. Been a busy ass...
  25. Replies
    8
    Views
    957

    Yeah I don't know if they put this in or not. ...

    Yeah I don't know if they put this in or not. Probably did. Basement was a dump. 50yr old guy still living with his mom.
  26. Replies
    8
    Views
    957

    Thank ya sir.

    Thank ya sir.
  27. Replies
    8
    Views
    957

    Total electric in a basement

    This job sucked. Crowded basement. Had to change plenum and takeoffs so I would have enough height for the fan coil. Had 3 trunk runs out of the plenum...

    ...
  28. Replies
    20
    Views
    3,304

    https://c4.staticflickr.com/8/7781/17659185703_8ea...

    https://c4.staticflickr.com/8/7781/17659185703_8ea1c0e93b_h.jpg we found quite a few this year
  29. Replies
    6
    Views
    1,256

    Why would you not use a cased coil?

    Why would you not use a cased coil?
  30. I wish you all would quit dogging on my work,...

    I wish you all would quit dogging on my work, jeez!
  31. Replies
    13
    Views
    1,720

    We haven't sold any, we aren't quick to jump on...

    We haven't sold any, we aren't quick to jump on the new equipment bandwagon. Know 2 dealers that sold several. Every one they sold they took out and put in the 2 stage heat pumps. One dealer has...
  32. Replies
    13
    Views
    1,720

    Skip the greenspeed and go with the 17 or 19 seer...

    Skip the greenspeed and go with the 17 or 19 seer heat pumps. Too many issues with greenspeed units.
  33. Replies
    13
    Views
    1,868

    Foam tape. Yes 3 pieces, Transition, filter box,...

    Foam tape. Yes 3 pieces, Transition, filter box, and plenum. This one actually had 16" flex thru the ceiling. I just put foam tape between each piece and screw them together. We don't use...
  34. Replies
    10
    Views
    2,163

    Infinity/evolution is simple. All 4 wires from...

    Infinity/evolution is simple. All 4 wires from the indoor unit, outdoor unit, all the thermostats, go to the same terminals. So in the zone board you have a G, Y, W, R set of wires, then your 2+...
  35. Replies
    16
    Views
    2,087

    Yellow jacket one.

    Yellow jacket one.
  36. Replies
    20
    Views
    3,304

    Ok heres the deal, yeah it will go all over the...

    Ok heres the deal, yeah it will go all over the floor. Then the homeowner will see it. The thing is we don't really have many if any drain issues. Media filters, no dirt on the coil no dirt in the...
  37. Replies
    10
    Views
    2,163

    Zoning made complicated... Infinity/evolution....

    Zoning made complicated...

    Infinity/evolution. Makes life simple. Best there is as far as zoning goes.
  38. Replies
    20
    Views
    3,304

    Circus I freeze them, basically get them ready to...

    Circus I freeze them, basically get them ready to fry and toss them in freezer, vacuum seal the next day.

    No purple primer here, it looks like crap.

    Trap is just something to plug up, no need.
  39. Replies
    20
    Views
    3,304

    I cooked about half and froze the rest for a...

    I cooked about half and froze the rest for a later date. Drip leg in the crawl, and customer was persistent that it didn't need one, he only worked for the gas company for 40 years. Yes there is a...
  40. Replies
    20
    Views
    3,304

    https://farm8.staticflickr.com/7700/16631766814_f7...

    https://farm8.staticflickr.com/7700/16631766814_f7c5f13d29_h.jpg

    some from earlier this week.
  41. Replies
    20
    Views
    3,304

    I'm going to call this one obnoxious piping.

    https://farm9.staticflickr.com/8693/17065969788_7fc7cfd0e5_h.jpg

    Just one of those jobs. Infinity modulating furnace and 2 stage ac.

    Started the day with swmbo wrecking her car, got a 2 hour...
  42. Replies
    13
    Views
    1,868

    Foil tape is on the truck. Yeah I hate them...

    Foil tape is on the truck.


    Yeah I hate them sitting on the floor, gotta stand on your head to work on them. Not to mention getting the door off is a pain.
  43. Replies
    16
    Views
    2,087

    24ga base yes, everything else 26ga. We...

    24ga base yes, everything else 26ga.

    We utilize a fold in on a lot of those pieces, specifically the filter connections. The filter box has a 1 1/2" flange so we just use a 1 1/2" fold in. Foam...
  44. Replies
    16
    Views
    2,087

    Another total electric

    Put in an Infinity system on this one. Weird return up the back. Everything has duct liner in it, in a garage
    https://farm8.staticflickr.com/7682/17239740695_031a7ad3e2_h.jpg
    ...
  45. Replies
    13
    Views
    1,868

    Total Electric changeout.

    https://farm8.staticflickr.com/7654/17041605260_c32e471e53_h.jpg
    https://farm6.staticflickr.com/5464/16606706284_b838ec55a4_h.jpg
    https://farm8.staticflickr.com/7701/16608941423_fd2b149e52_h.jpg...
  46. Replies
    13
    Views
    1,607

    With as many leaky coils as I see, this is...

    With as many leaky coils as I see, this is completely wrong lol.

    Use media filters, its like a nice job but you forgot a step.. Looks pretty good otherwise.
  47. Thread: New 92%er

    by jimmyed
    Replies
    17
    Views
    2,550

    Looks a lot better than most, Wheres all the foil...

    Looks a lot better than most, Wheres all the foil tape?!?!
  48. Replies
    26
    Views
    3,149

    Man what a design flaw.

    Man what a design flaw.
  49. Thread: New 92%er

    by jimmyed
    Replies
    17
    Views
    2,550

    Why the pressure fitting in the flue? Don't you...

    Why the pressure fitting in the flue? Don't you normally try to get the intake outside as well?
  50. Replies
    26
    Views
    3,149

    Only option to run flues in front of coil?

    Only option to run flues in front of coil?