Search:

Type: Posts; User: inf_sys

Search: Search took 0.00 seconds.

  1. Replies
    30
    Views
    2,809

    I would be very interested. My email is in my...

    I would be very interested. My email is in my profile. Please email me.

    Thanks
  2. Replies
    2
    Views
    1,137

    If they are recommending the model TP-PRH01 then...

    If they are recommending the model TP-PRH01 then that is a great thermostat and have every option and more. The nice thing about this stat is that they can install using less wires and that may be...
  3. Replies
    7
    Views
    3,514

    The furnances other than the 120K are eligible...

    The furnances other than the 120K are eligible for the 30% up to the $1500.00 tax credit for equipment and installation since they are 95% AFUE. The 120K models using only the ECM variable speed...
  4. Replies
    7
    Views
    3,514

    As far as the 120K unit it is rated at 93.3%. I...

    As far as the 120K unit it is rated at 93.3%. I am sure this is due to the physical size of the primary and secondary heat exchangers as well as the air flow required of a unit of that size. Same...
  5. Replies
    7
    Views
    3,514

    They are variable speed blowers not X-13. I...

    They are variable speed blowers not X-13. I expect that the ARI ratings may be revised in the future as this is a new unit. Rheem has usually had some smaller increases in SEER when they match their...
  6. Replies
    1
    Views
    1,678

    Bryant markets using the Aero Quiet system. You...

    Bryant markets using the Aero Quiet system. You can lookup detailed info on the model number at

    http://www.catalog.bryant.com/gen/model_search/1,3005,CLI1_DIV70_ETI5617,00.html

    As far as age...
  7. Agreed. I just think he has a better chance the...

    Agreed. I just think he has a better chance the first time with someone that is used to working with aluminum on aluminum. No a big fan of trying super seal or 2 part epoxy.
  8. Replies
    3
    Views
    394

    Heil used the brand code N that the model starts...

    Heil used the brand code N that the model starts with. Made by ICP (International Comfort Products Corporation). May have tagged with other brand names such as Keeprite.
  9. Replies
    15
    Views
    972

    I would look for a contractor with zoning...

    I would look for a contractor with zoning experience. You will probably want to look at a whole house dehumidifier with some dedicated duct runs to assist with the dehumidification. Here in FL new...
  10. We come across this with some brands where they...

    We come across this with some brands where they used aluminum condenser coils, some residentail ac and some commercial coolers. On newer units it made sense to remove the coil and take to our metal...
  11. Replies
    2
    Views
    461

    It would depend on insulation of the garage. Most...

    It would depend on insulation of the garage. Most likely you would not be happy with the increased energy bill or ability to control the temperature unless it was zoned with a zoning panel, damper,...
  12. Replies
    1
    Views
    363

    Check this out from Emerson. Looks like they have...

    Check this out from Emerson. Looks like they have been in operation since 2007 doing some production of their scroll technology in Mexico.
    ...
  13. Replies
    15
    Views
    1,385

    Yep. Look like you have an issue there. I would...

    Yep. Look like you have an issue there. I would put the door back on and call a local Lennox dealer to check it and have it fixed before winter comes and Mom has to deal with an after hours call.
  14. Replies
    15
    Views
    3,939

    Check out http://www.earthtoair.com

    Check out http://www.earthtoair.com
  15. Replies
    4
    Views
    2,197

    Seems like people are responding to something...

    Seems like people are responding to something other than your question. Crown Products make good sturdy grilles. I use MetalAire which are standard aluminum. I would call your installer back and see...
  16. The other point you want to talk with your...

    The other point you want to talk with your contractor about if you are going to pull from a well is that some municipalities have started requiring two wells, one to pull and one to dump. That will...
  17. Sounds like a mess that I am sure will be...

    Sounds like a mess that I am sure will be happening not just in your area in the near future. I see service call $$ in the future. It depends on the manufacturer as far as the coils go but they would...
  18. The geothermal heat pump consortium at...

    The geothermal heat pump consortium at http://www.geoexchange.org has a great locator for finding a registered installer. It used to be on their home page.
  19. We are a certified geothermal installer and...

    We are a certified geothermal installer and operation of a water source heat pump will vary with entering water temperature but closed loop systems which are always installed below local calculated...
  20. The cost is going to be based in the local market...

    The cost is going to be based in the local market for well drilling or land excavating. There is not going to be a good ballpark that is going to be valid across the country. Standard geothermal...
  21. The output on that unit is 20,000 to 26,000 Btu/h...

    The output on that unit is 20,000 to 26,000 Btu/h depending on matchup. Please see attached guide.

    Dave
  22. Replies
    4
    Views
    2,962

    Low pressure lockout would occur if the charge...

    Low pressure lockout would occur if the charge was too low. The installer or service company would need to check the charge using proper methods to verify. The installer can also review the past...
  23. Replies
    4
    Views
    2,962

    The only error codes for the outdoor units on...

    The only error codes for the outdoor units on operation other than electrical or communication:

    Code 76 Low stage did not start three times
    Code 78 High stage did not start three times
    Code 81...
  24. Replies
    2
    Views
    532

    Here you go. Please see attached.

    Thank you,

    Dave
Results 1 to 24 of 24