Search:
Type: Posts; User: jackmorgan
Search: Search took 0.00 seconds.
-
01-09-2009, 07:54 PM
Thread: Duct Liner Supplier in Canada
by jackmorgan- Replies
- 2
- Views
- 635
exactly what i was looking for. Thanks. Jack
exactly what i was looking for. Thanks.
Jack -
01-09-2009, 08:38 AM
Thread: Duct Liner Supplier in Canada
by jackmorgan- Replies
- 2
- Views
- 635
Duct Liner Supplier in Canada
Hi,
I cannot find a supplier for duct liner anywhere in Ontario, Canada. For that matter i haven't even been able to find anything on the net. I'm looking for around 100 square feet of 1/2 inch... -
06-24-2008, 12:39 PM
Thread: Return air for two storey house
by jackmorgan- Replies
- 1
- Views
- 404
Return air for two storey house
Hi,
Quick question. In a two storey house with returns on each level (basement, first floor, second floor) would it be advantageous to damper them so that in the summer only the 1st and second... -
05-06-2008, 08:48 AM
- Replies
- 11
- Views
- 732
Still in the design stage. I'm aware many...
Still in the design stage. I'm aware many installers will just use one size, but my question is "is this the correct way of doing things?". What would you do for your own house? I want to make...
-
05-06-2008, 08:45 AM
- Replies
- 11
- Views
- 732
So you would use a 5 inch duct for a 25 square...
So you would use a 5 inch duct for a 25 square foot powder room?
-
05-06-2008, 08:44 AM
- Replies
- 11
- Views
- 732
The "experts" are just some colleagues that have...
The "experts" are just some colleagues that have been in the business for 20+ years. Perhaps they are just taking the easy way out by using 6 inch branches for every room.
-
05-05-2008, 10:54 PM
- Replies
- 11
- Views
- 732
How do dampers affect velocity and flow?
Hopefully someone can enlighten me ...
Dampers are used to control the volume of air that enters a branch, but how do they affect velocity? I would assume the air speeds up as it flows through... -
04-10-2008, 11:51 AM
Thread: Radial design for two storey house
by jackmorgan- Replies
- 2
- Views
- 374
Radial design for two storey house
Hi,
Just wondering what issues I would have with using a radial duct design in a two storey house. Basically, I want to have all dampers centrally located in the utility room to make... -
04-03-2008, 08:23 AM
Thread: HVAC calc questions
by jackmorgan- Replies
- 6
- Views
- 770
only enter exterior walls. when you enter...
only enter exterior walls. when you enter interior walls with no insulation the program thinks you have an exterior wall with no insulation and as such the loads will be off the chart.
-
04-03-2008, 08:18 AM
Thread: Minimum design temperature
by jackmorgan- Replies
- 0
- Views
- 640
Minimum design temperature
Hi,
I'm installing a new hvac system, including ductwork, in a 2000 square foot,
30 year old home with upgraded windows, doors, insulation, etc. The customer would like to be able to have an... -
02-12-2008, 02:28 PM
Thread: Duct Distribution / layout help needed
by jackmorgan- Replies
- 3
- Views
- 822
Duct Distribution / layout help needed
Hi,
I'm currently designing a duct system for a two storey home plus finished basement. It currently only has electric baseboards (no ductwork) and would like to add gas heat and a/c.
I am...
Results 1 to 11 of 11