  1. Replies
    8
    Views
    558

    Well worth the time to go. They are complicated...

    Well worth the time to go. They are complicated little bastards. Thank goodness they are so reliable.
  2. Replies
    34
    Views
    1,588

    I use a Dtek and have had very good luck finding...

    I use a Dtek and have had very good luck finding leaks but I have had to replace it more than once. I have heard good things about the H10 but never used one.
    I was told by my equipment supplier...
  3. Replies
    6
    Views
    619

    Drain Tee Trap 1171916 , ICP part number. It...

    Drain Tee Trap 1171916 , ICP part number. It used to come with the furnace. The new ICP furnaces dont use it anymore.
    icpindexing.toddsit.com/documents/086477/44106104300.pdf
  4. Replies
    31
    Views
    2,274

    I replaced one of these two winters ago with a...

    I replaced one of these two winters ago with a cozy floor model. Easy install.
  5. Replies
    3
    Views
    497

    Condensation is forming in the hose. On the...

    Condensation is forming in the hose. On the pressure switch nipple there is a small vent hole which is probably plugged with dirt. It maybe on the backside of the nipple but use a small piece of wire...
  6. Replies
    41
    Views
    3,553

    4 hours minimum but I aint starting it in the...

    4 hours minimum but I aint starting it in the afternoon.
  7. Replies
    51
    Views
    3,585

    If it was me I would get another set of...

    If it was me I would get another set of Digi-Cools. The reason for me is cuz I love them but the support is second to NONE!
    I sent an email complaining about the first velcro temp probe they came...
  8. Replies
    10
    Views
    1,224

    I started using Acowin with the Acotruck and on...

    I started using Acowin with the Acotruck and on call modules since Jan 1 and I love it. No invoices to write out, no paper to push from desk to desk. I'm still learning everything I can do with it...
  9. Replies
    11
    Views
    1,016

    I see this was a few weeks ago but I too have...

    I see this was a few weeks ago but I too have been a Service Roundtable member on and off for years. Their website is loaded with tons of ideas and marketing material. Its $50 per month and you can...
  10. Replies
    5
    Views
    2,043

    If the duct work is in good condition and sized...

    If the duct work is in good condition and sized properly there is no reason not to reuse it.
  11. A two stage unit is sized the same way as a...

    A two stage unit is sized the same way as a single stage unit. A four ton single stage is rated at approximately 48,000 btuh and a two stage unit running with both stages would be 48,000 btuh and...
  12. Replies
    28
    Views
    2,285

    I will go against the grain here and agree with...

    I will go against the grain here and agree with your line of thinking. I do not like to reuse refrigerant even with new tanks. Unless I am going to use a brand new recovery unit also, which isn't...
  13. Replies
    22
    Views
    2,478

    Back to the original question. Can you just...

    Back to the original question. Can you just replace the outdoor unit? Of course you can. Is it advisable...NO
  14. Replies
    8
    Views
    745

    my question is where are you located? 90*...

    my question is where are you located? 90* outside?
  15. I would have to agree with you. The valve will...

    I would have to agree with you. The valve will have some markings on it indicating direction of flow.
  16. Replies
    23
    Views
    2,083

    Living in New England if we waited for the...

    Living in New England if we waited for the temperature to be in the 70's we will be starting spring checks in June.
    If it's a new start up I would wait till its warmer but to do a spring check you...
  17. Replies
    20
    Views
    2,922

    I have installed a lot of mitsubishi systems,...

    I have installed a lot of mitsubishi systems, single and Multi head units with very few problems. Go with Mitsubishi. You wont have to question whether you made the right decision.
  18. Replies
    13
    Views
    1,511

    The motor doesn't know whether its a condenser...

    The motor doesn't know whether its a condenser fan motor or a blower motor, if all the specs are the same it should work fine. The problem you may encounter is condenser fan motors are usually...
  19. Replies
    17
    Views
    1,417

    This is not acceptable to me! There had to be a...

    This is not acceptable to me! There had to be a better way to run the piping but I can't see your house from here. He apparently does not have any tiewraps to bundle the piping and low voltage wiring...
  20. The majority of indoor coil leaks are in the coil...

    The majority of indoor coil leaks are in the coil surface area and not on the coil ends. The tubing that is leaking is covered by the coil fins. So pouring soap bubbles on it usually does not yield...
  21. If there is a leak in the indoor coil no amount...

    If there is a leak in the indoor coil no amount of bubbles poured on it are likely to show anything. That's my two cents.
  22. Replies
    3
    Views
    1,021

    it sounds to me like your machine has no...

    it sounds to me like your machine has no refrigerant in it.
  23. Replies
    2
    Views
    1,960

    The pin selection on the control board tells the...

    The pin selection on the control board tells the motor what cfm range it should be running at depending on what the system is calling for. Ex: fan only, heat pump, emergency heat only. For optimimum...
  24. Thread: Heat Pump Woes

    by dngtig
    Replies
    65
    Views
    5,043

    Kevin, I don't think there was a drier in the...

    Kevin, I don't think there was a drier in the system. The 3rd guy added a drier. The 2nd guy should have installed a drier when he recovered and recharged but he was being paid my AHS so he probably...
  25. Thread: Heat Pump Woes

    by dngtig
    Replies
    65
    Views
    5,043

    To me it sounds like you have had service guys...

    To me it sounds like you have had service guys who are not familer with heat pumps. The second company seems to be the most experienced. I would call them directly and have them look at it.

    Your...
  26. Replies
    10
    Views
    1,143

    It is an industry wide problem. The two brands I...

    It is an industry wide problem. The two brands I sell both have had problems. I ordered a coil today for a two year old system. This will be the third coil installed. Original system 19 years old no...
  27. If it's a heat pump it should be running. Do you...

    If it's a heat pump it should be running. Do you have a gas or oil furnace?
  28. Replies
    33
    Views
    3,027

    The Heil DX1400 is Heils Mainline unit which is...

    The Heil DX1400 is Heils Mainline unit which is not a builders grade model. I am not familier with Frigidairs builders model but builders grade is usually the cheapest model they have.
  29. Replies
    15
    Views
    6,175

    You lost refrigerant somewhere as stated by...

    You lost refrigerant somewhere as stated by jpsmith so you have a leak, it maybe a big leak or it maybe very small and difficult to find but it can be found. If you have crystals in the line there...
  30. Replies
    33
    Views
    3,027

    I perfer the Heil/ICP over the Frigidaire/Nordyne...

    I perfer the Heil/ICP over the Frigidaire/Nordyne but if I think either one would be fine. Oh yea, Heil is not owned by Carrier it is owned by United Technologies which also owns Carrier, it's not...
  31. Replies
    49
    Views
    7,402

    Someone has added about 19,361 screws to the...

    Someone has added about 19,361 screws to the Pulse furnaces you have been working on.:confused:

    I haven't worked on hundreds but the dozen I have all have 6 bolts holding the cover on.
  32. Please explain how a dirty air filter could cause...

    Please explain how a dirty air filter could cause a blocked flue switch to trip:confused:
  33. Replies
    65
    Views
    4,085

    The a-coil should be sitting on a flange or shelf...

    The a-coil should be sitting on a flange or shelf inside the duct work. If the drain got plugged you will have water on the floor. Yes they plug up often if they have a trap. If your coil is mounted...
  34. Thread: mapp gas

    by dngtig
    Replies
    43
    Views
    6,033

    I have to agree with you. If you know how to...

    I have to agree with you. If you know how to braze you could use almost anything that generates enough heat but alot of these guys today think the pipe is supposed to be glowing red.
  35. Thread: Hole Pro cutter

    by dngtig
    Replies
    9
    Views
    1,697

    Thank you, Thats why I ask.

    Thank you, Thats why I ask.
  36. Thread: Hole Pro cutter

    by dngtig
    Replies
    9
    Views
    1,697

    Hole Pro cutter

    Has anyone used this hole cutter? I need to cut holes for Mitsubishi units in plaster with wood lathes. Does anyone have a better solution?
    http://www.holepro.com/hvac.html
  37. Replies
    140
    Views
    12,916

    If each area worked as the contractor discribed...

    If each area worked as the contractor discribed your room would only be warm at the floor. You would have to lay down to feel comfortable.:D
    Really the velocity of the air coming out of the register...
  38. Replies
    140
    Views
    12,916

    I would go with the high return if the supplies...

    I would go with the high return if the supplies are in the floor. If the supplies where in the ceiling I would go with the low returns. If cost is a problem go with the floor returns they will work.
  39. Replies
    2
    Views
    1,014

    My opinion is if you can fit conventional duct...

    My opinion is if you can fit conventional duct work in your house do it. You will have more equipment options plus a much quieter machine. I install a good amount of high v systems but only where...
  40. Replies
    48
    Views
    10,609

    My heat pump works great in CT. In Alabama heat...

    My heat pump works great in CT. In Alabama heat pumps should sell like hot cakes. Everyone should have a heat pump with a high effiency gas furnace as second stage.
  41. Replies
    22
    Views
    2,978

    I am extremely happy with my Dtek select. I have...

    I am extremely happy with my Dtek select. I have the older D-tek and liked that one but was unable to pick up R404 but the new select works great on all refrigerants in my experience.
  42. Replies
    3
    Views
    468

    Yes you should replace the indoor coil also. You...

    Yes you should replace the indoor coil also. You are buying a high effiency outdoor unit, you will not achieve anything close if you do not connect it to a high effiency coil. Will it work with the...
  43. Replies
    5
    Views
    2,758

    I haven't installed any carrier coils but it is a...

    I haven't installed any carrier coils but it is a problem with all manafacturers. Here's a article on it http://www.hydro-temp.com/help/drawings/Formicary_Corrosion.pdf
  44. Replies
    3
    Views
    468

    You are not supposed to list prices on here but...

    You are not supposed to list prices on here but yes the coils need to be replaced.
  45. Replies
    14
    Views
    2,067

    Dusty Rose, Wasn't he a big fat wrestler with a...

    Dusty Rose, Wasn't he a big fat wrestler with a bionic elbow drop?:confused:
    Oh wait a minute that was Dusty Rhodes, sorry.
  46. I think if you work in the south where you still...

    I think if you work in the south where you still have hot weather you should do fine. I personaly have not had my a/c on for 2 weeks so I don't think most of my customers have either.:mad: Business...
  47. Replies
    23
    Views
    2,425

    Never miss a chance to sell:D:D

    Never miss a chance to sell:D:D
  48. Replies
    25
    Views
    4,512

    What are you guys complaining about? All the...

    What are you guys complaining about? All the disconnects are numbered, one of them says 2nd #6. I wonder if there are two #6 units?:eek:
  49. Thread: york ahu

    by dngtig
    Replies
    3
    Views
    1,820

    If there are no heaters installed you need to...

    If there are no heaters installed you need to have the no heat plug installed on the board (white plug with one jumper wire in it).
  50. Replies
    30
    Views
    3,643

    I use my cooper clamp thermometer it reacts...

    I use my cooper clamp thermometer it reacts quickly and is all I have to do is clamp it on the line. I would prefer to use the probe that came with the manifold seeing how that was one reason I...