  1. Replies
    10
    Views
    1,390

    so here's an update replaced the board and...

    so here's an update replaced the board and condenser fan motor and unit is working fine now
  2. Replies
    14
    Views
    1,845

    Dolly?.....toss it to the corner or the roof n...

    Dolly?.....toss it to the corner or the roof n call it a day...lol j/k
  3. Replies
    10
    Views
    1,390

    the liquid line runs through the interior panel...

    the liquid line runs through the interior panel so the condenser is probably dirty ..ok now i know why that wall really heated up I checked condenser fan not stuck and windings ohmed out will...
  4. Replies
    10
    Views
    1,390

    [QUOTE=jim147;13655221]IIRC that unit has a yoder...

    [QUOTE=jim147;13655221]IIRC that unit has a yoder loop between the doors to keep moisture down.

    Yes I found out that the tube runs along the interior walls so that explains that and yes it uses a...
  5. Replies
    10
    Views
    1,390

    Yes it is strange that the wall would get so hot,...

    Yes it is strange that the wall would get so hot, i was thinking that it might have been the ice maker too since it is the only thing close to that wall but they told me that it hasn't worked in...
  6. Replies
    10
    Views
    1,390

    Side By Side not cooling

    Hello, so my cousin asked me to take a look at his Samsung RS2630sh side by side after he noticed that the wall that separates the freezer and the cooler was extremely hot then he noticed that the...
  7. Replies
    6
    Views
    1,669

    ::DD:

    ::DD:
  8. Replies
    49
    Views
    3,684

    charging by adding 35 to ambient

    Hello I'm just wondering If anyone has ever charged an R22 system by adding 35 to ambient temp and then us that number as the saturated temp and converts it to pressure...JUST WONDERING
  9. Replies
    51
    Views
    11,883

    Give the guy a break hes just rusty, I didn't...

    Give the guy a break hes just rusty, I didn't start working in the field until a couple years after I graduated at first I too did not remember many things I was taught.......and after a few year I...
  10. Replies
    17
    Views
    1,741

    Replace the oil in the compressor purge the evap...

    Replace the oil in the compressor purge the evap and condenser replace LLFD and pull a good vacuum
  11. Replies
    41
    Views
    3,644

    Don't forget the transformers

    Don't forget the transformers
  12. Sticky: I work on a lot of bards also mostly for cell...

    I work on a lot of bards also mostly for cell sites , common problem is wrong gauge wiring from the manufacture
  13. Sticky: well I graduated from high school and didn't...

    well I graduated from high school and didn't really want to go to a 4 year college so i enrolled at a trade school hvac caught my attention and i stuck to it.finished the course couldn't get a job do...
  14. Replies
    31
    Views
    2,933

    [QUOTE=hvaclover;13361361]Yeah, and at 30"HG on...

    [QUOTE=hvaclover;13361361]Yeah, and at 30"HG on your lo-side gauge you have how many microns? 25,000, and the mfg says as low as 200 microns?


    Incorrect.

    29.916"hg = 100micron

    28.92"hg =...
  15. Replies
    4
    Views
    854

    Good to hear good things about this scale because...

    Good to hear good things about this scale because i just bought one lol
  16. Replies
    31
    Views
    2,933

    yea I do like it but I prefer charging by the...

    yea I do like it but I prefer charging by the "split":grin2:
  17. Replies
    31
    Views
    2,933

    LOL just tring to keep u on your toes jp:whistle:

    LOL just tring to keep u on your toes jp:whistle:
  18. Replies
    4
    Views
    854

    TIF 9010a scale

    Has anyone ever used this scale?
  19. Replies
    31
    Views
    2,933

    You don't need a micron gauge to know your...

    You don't need a micron gauge to know your pulling a good vac your gauges also tell you, just make sure you change the oil in your pump after every use
  20. Replies
    10
    Views
    1,263

    sounds like a restriction probably the drier

    sounds like a restriction probably the drier
  21. Replies
    31
    Views
    2,933

    LOL::DD:

    LOL::DD:
  22. Replies
    12
    Views
    1,306

    Replaced the cap tube and drier , system is...

    Replaced the cap tube and drier , system is working like a champ.:grin2:
    Thanks 4 the replys:cheers:
  23. Replies
    48
    Views
    9,998

    BTU's per square feet

    I know theres alot to consider (light,windows, ect) but in general what would u use?
  24. Replies
    19
    Views
    2,592

    I get some of those too but i collect after for...

    I get some of those too but i collect after for the same reason (customer satisfaction)
  25. I put the oil back in through the discharge right?

    I put the oil back in through the discharge right?
  26. I knew I forgot something.. I didnt after took...

    I knew I forgot something.. I didnt after took the parts off I headed to the supply house thinking I was going to get the parts today..Newbie mistake ...If I pull a really good vacuum u think i might...
  27. Replies
    12
    Views
    1,306

    lol tell me about it I sweated the cap tube at...

    lol tell me about it I sweated the cap tube at the evap and when i pulled it out the cap tube broke leaving 3 inches of tube inside the evap which was a pain to get out because it was crimped lol ...
  28. I removed the cap tube and filter tomorrow I will...

    I removed the cap tube and filter tomorrow I will be installing new ones after I purge the system. if this doesn't work i don't know what else it could be...compressor? I dont under stand how the...
  29. Replies
    12
    Views
    1,306

    Yes First thing I did was clean the coils and...

    Yes First thing I did was clean the coils and check the fans. I'm going to nitro the condenser and evap and get a new drier and cap tube and hope its not the compressor
  30. suction line cold but box does not reach temp

    Hello,
    So I'm dealing with a reach-in cooler 134a that is not reaching temp lowest it goes is 49, my high side is at 320 and low side at 20, my suction line is cold and sweating. maybe restricted...
  31. Replies
    12
    Views
    1,306

    True Refrigerator wont reach temp

    Hello,
    So I'm dealing with a reach-in cooler 134a that is not reaching temp lowest it goes is 49, my high side is at 320 and low side at 20, my suction line is cold and sweating. maybe restricted...
Results 1 to 31 of 33