    i really wouldnt want a veto bag that thing is way too small but this clc 75 pocket thing looks nice already know i wont have any wrenches in it but looks like a good spot for ductknife bits...
  2. Replies
    19
    Views
    1,945

    Tired of tool bags

    Here's the deal I work mon-friday sometimes on saturday and im sick of lugging around my big old husky toolbags. It becomes a real task when im climbing up ladders, getting on roofs, or flat out...
  3. Replies
    14
    Views
    1,952

    size

    small makita variable speed ive done 4-5" holes but it goes through fast
  4. Thread: Accy torches?

    by jb00gz
    Replies
    12
    Views
    1,698

    uniweld torch cutting outfit

    model klc100p use it on everything small and big and doesnt break the bank
  5. Replies
    14
    Views
    1,952

    yep

    angle grinder and a diamond core bit can be used wet/dry special bit
    the fastest for me
  6. Replies
    24
    Views
    3,545

    what is the impact for?

    honestly like i said i can use my 7.2v black n decker vpx for most things as in taking unit apart and screwing in self tapping metal screws.
    the problem happens when i need to drill into a concrete...
  7. Replies
    14
    Views
    1,952

    angle grinder

    I pull out my makita angle grinder and make a 5" hole in a wall in less than a minute :)
    *most walls are block so this works most time
    sometimes i do need grandpapies long masonry bit
    *personal...
  8. Replies
    204
    Views
    29,468

    duct knife :)

    use my ductknife for everything lol
    screwdriver
    prybar
    knife
    hole puncher
    and whatever else i might encounter when everything is to far away
  9. Replies
    49
    Views
    7,355

    lol

    why don't you try using a glove heh thats what i do
    buying this ball valve though only because it makes my job look that much cooler :)
  10. Replies
    24
    Views
    3,545

    man

    i have the black n decker 7.2v lithium ion mini drill for most things it is a great tool but for hvac I really want to replace it with the bosch 12v mini drill impactor (you really need that extra...
  11. you need to be more informant

    first you say barely blowing from vents
    you need to say is it cold air barely blowing or warm
    if its nice cool air have the service tech bump up the fan speed on the air handler
    if its not have...
  12. Replies
    18
    Views
    2,051

    always someone

    should have quoted the guy flaming a very respectable company but anyways
    I feel the service tech did the job just as I would have performed this. The fact that the system doesn't use r410a doesnt...
  13. Replies
    14
    Views
    1,207

    hmm

    have the tech redo your drain line or fix it properly *send someone better :)
    if he cant at least make a new drain and make it work properly he needs to leave your home immediately
  14. i'll give you half a diag

    make sure that pump device *condensate pump* is pumping water
    and a cap goes over the open pipe in the top**
  15. heres your test

    1. Stop everything your doing
    2. Look at the unit, your bucket of water and all the things connected
    3. Think how you would get the water out of the house and not into the bucket
    If you succeed it...
  16. Replies
    54
    Views
    7,708

    fieldpiece

    lt17a meter is great can check amps temp volts caps ncv everything
    sc77 nice meter also but the lt is m baby love the backlight
  17. Replies
    21
    Views
    1,880

    eeek

    ya that would suck if your roof caved in saw that happen before :eek:
  18. Replies
    49
    Views
    15,285

    why

    why dont you just make the return larger or add more returns and tie them in together this would take the noise down a lot its so loud because its the only one and its not that big :cool:
  19. Replies
    49
    Views
    2,958

    where

    hallways are good big space less noisy
    any big rooms are good *master livingin large homes all rooms located in front door at least 6ft from closest supply
    bathrooms no you dont want to do a #2...
  20. Thread: New System

    by jb00gz
    Replies
    5
    Views
    706

    umm

    id do it but it would involve asking more questions depending on what he'd need done like
    1) what size units are there now
    2) is he running new copper
    3) how many returns and supplies and what...
  21. Replies
    10
    Views
    4,707

    sorry

    this is the scary part...
    if i was fixing it id flush the lines because r22 and r410a mixed could cause likewise problems. Then match the pistons...
    :eek:
  22. Replies
    10
    Views
    4,707

    ok

    first of all 9xx is way too much money to change to a tsx thats likely almost enough to replace the entire coil. Now to some explaining the piston is to control your airflow so that you dont get too...
  23. Replies
    113
    Views
    10,731

    noone bashed

    i didnt bash goodman it is an alright brand im just saying most startup companies use it because the sole fact it is cheap. And some well established companies do use goodman but few because they...
  24. Thread: HELP!

    by jb00gz
    Replies
    11
    Views
    1,042

    you said the system was running good

    just clean or change the coils and use all the extra money to replace your duct which i can almost guarantee filled with mold and or other things
  25. 15 years

    why didnt i catch that yeah the best warranties are only 10 years
  26. ya

    id get a service technician out there
    and when he is there ask him what he might think is the problem
    if he goes up there with no tools
    be prepared for him to try to sell you a new system lol...
  27. Replies
    3
    Views
    523

    hrmm

    you have 2 condensors outside you need to go out and feel that there is luke warm not cold air coming out of both if so. the problem is in the ductwork you need to have to redesigned so that it...
  28. Replies
    113
    Views
    10,731

    why

    because most comapnys that sell goodman are new and they in turn hire new installers which 90% don't know how to get the job done right so things fail especially the conversion from r22 to 410a its...
  29. Replies
    5
    Views
    554

    things that could be wrong

    check your return air make sure you have enough
    and wait for it to unfreeze and check your breakers
  30. Blame Both

    First off it's the subcontractors fault for a bad installation, but secondly it is the head contractors fault before the sub contractor for hiring that person to do your job. So both of them are to...
  31. Replies
    15
    Views
    1,113

    im only seeing bits about your problem

    im thinking that you have a vertical airhandler and are using a closet for the return theres two ways to get it quieter and perform better
    1) turn the blower fan speed down
    2)add a return...