  1. i miss you too twilli. you are so cute. :o) ...

    i miss you too twilli. you are so cute. :o)

    another issue with the rheem mod is that there is two stages for AC motor control L and H, or 1 and 2. these are labeled on the board as YL and YH or Y1...
  2. Replies
    17
    Views
    1,058

    i did exactly that: bought a compressor off ebay...

    i did exactly that: bought a compressor off ebay and gave it to my mechanic to install and vacuum the system. then i installed the refrigerant myself. after i removed the fitting, the shreader valve...
  3. do you have 1 or 2 stage AC? if you have single...

    do you have 1 or 2 stage AC? if you have single stage AC make sure the tstat Y wire is connected to YH on the IFC in the furnace. if its connected to YL, the blower will only run on the low speed...
  4. Replies
    155
    Views
    12,220

    TESP - between filter and furnace, coil and...

    TESP - between filter and furnace, coil and furnance

    the reading you see was with fan only which is supposed to be 500 CFM. i find the furnace has a non-linear correlation between CFM and TESP. i...
  5. Replies
    155
    Views
    12,220

    its overkill but its cool (and surprisingly...

    its overkill but its cool (and surprisingly practical) :D
  6. Replies
    155
    Views
    12,220

    thats what i am reading off my Gold

    thats what i am reading off my Gold
  7. Replies
    155
    Views
    12,220

    see post 103

    see post 103
  8. Replies
    155
    Views
    12,220

    ok beenthere. i think you are honestly trying to...

    ok beenthere. i think you are honestly trying to be helpful. sorry for being defensive, its just that i feel there has been a lot of unwarranted attacks on me in this forum.

    the actual CFM was...
  9. Replies
    155
    Views
    12,220

    the - line was run through the furnace wall...

    the - line was run through the furnace wall through one of the unused electrical ports. it was taped into position and the hole sealed. the filter was sealed as it would be in regular operation. the...
  10. Replies
    155
    Views
    12,220

    with a clean filter the TESP drops to 0.19" cw @...

    with a clean filter the TESP drops to 0.19" cw @ 800 CFM on cooling. looks like the install is in spec. thanks for all your help.
  11. Replies
    155
    Views
    12,220

    read what i wrote. 800 CFM on cooling. the system...

    read what i wrote. 800 CFM on cooling. the system is in spec the filter does not cause an appreciable static pressure increase.
  12. Replies
    155
    Views
    12,220

    static pressure of the rheem modulating is 0.15"...

    static pressure of the rheem modulating is 0.15" cw on cool (800 cfm / 2 ton AC) with no filter installed, and 0.21" cw with the allergy gold electrostatic installed and not cleaned for a month.
    ...
  13. Thread: Good or bad?

    by plexus
    Replies
    24
    Views
    1,225

    i wasnt hacked. i got a very clean install. and...

    i wasnt hacked. i got a very clean install. and everything is by the book. unlike this job which has so many holes in it (literally) its not even in the same league.

    to the OP on here... be...
  14. Thread: Good or bad?

    by plexus
    Replies
    24
    Views
    1,225

    its amusing to me that you guys will call this a...

    its amusing to me that you guys will call this a hack job (which it is) and the job my contractor did a hack job (which is no where near in the same shame league as this job). just goes to show you...
  15. Replies
    155
    Views
    12,220

    Yes Yazza thats the dealio. Its real easy for...

    Yes Yazza thats the dealio. Its real easy for people to say "get the best contractor" and then just step away. Oh and then slag you like no tomorrow when you share you experience on the forum. Alas....
  16. Replies
    155
    Views
    12,220

    great. congrats. you'll enjoy the furnace.

    great. congrats. you'll enjoy the furnace.
  17. Replies
    155
    Views
    12,220

    i appreciate your comments and concerns and...

    i appreciate your comments and concerns and advice. dont get me wrong. but the only way to find a good contractor is to have them do jobs for you so you can see (or go on referrals but if the other...
  18. Replies
    155
    Views
    12,220

    there is a hole between the coil and furnace that...

    there is a hole between the coil and furnace that the measurement was taken from. no worries. i will measure it myself and then i will know.

    this is why you have to learn how do some of these...
  19. Replies
    155
    Views
    12,220

    ok i'll do it myself when i get my own meter. i...

    ok i'll do it myself when i get my own meter. i just assumed thats where we took the readings from as i dont see any holes drilled into the furnace which is the only way to get a reading after the...
  20. Replies
    155
    Views
    12,220

    before filter and before coil

    before filter and before coil
  21. Replies
    155
    Views
    12,220

    TESP is 0.42 @ 1200 CFM. did not test PD but will...

    TESP is 0.42 @ 1200 CFM. did not test PD but will do soon. I am going to install a magnehelic pressure gauge on supply and return for easier monitoring.

    The other issues with the install have been...
  22. Replies
    155
    Views
    12,220

    it is only "exact" to the degree that any given...

    it is only "exact" to the degree that any given hvac contractor considers exact. take a look at the hall of shame and all the differing opinions on this forum from the "pros". its not exact and like...
  23. Replies
    69
    Views
    3,293

    ok i'll send you my email. as for the filter i...

    ok i'll send you my email. as for the filter i dont know man, the boys on here say anything but a 5" pleated filter is bad for the motor. im having my contractor measure TESP tomorrow so we'll see. i...
  24. Replies
    155
    Views
    12,220

    sounds like HVAC contractors. sorry i couldnt...

    sounds like HVAC contractors. sorry i couldnt resist ;)
  25. Replies
    155
    Views
    12,220

    just spoke with my insurance company. i asked the...

    just spoke with my insurance company. i asked the question in 3 different ways and got the same answer:

    HOME INSURANCE WILL NOT BE AFFECT BY THE ABSENCE OF A PERMIT FOR A FURNACE REPLACEMENT.
    ...