  1. The CBX27UH-030 has a slightly larger coil than...

    The CBX27UH-030 has a slightly larger coil than the CBX32MV-024/030. That May help. But you will still need the same static to move the air through the ducts.
  2. I had a customer do that years ago, it was an...

    I had a customer do that years ago, it was an office supply store. They put a pitched roof over a leaking flat roof with a packaged air conditioner on the original roof. The installed a louver on the...
  3. Can you put the condenser on the outside balcony?...

    Can you put the condenser on the outside balcony? Where are you located?
  4. Could be a piece if trash in the line. We call it...

    Could be a piece if trash in the line. We call it Flat Stone Disease.

    I went on a call in a condo once that had the same problem. Sometimes it would work fine, sometimes pump down and shut off....
  5. Sticky: I just saw this thread. I am so sorry to hear of...

    I just saw this thread. I am so sorry to hear of your loss.

    My Father died from brain cancer in 2006 and I still miss him.

    But that does not compare to loosing your wife.

    My thoughts are...
  6. That trap is very shallow. It is possible for a...

    That trap is very shallow. It is possible for a VS blower to pull through a shallow trap. I would like to see a 2.5 inch deep trap on that installation. Or deeper. Turning vanes in the return plenum...
  7. Is it leaking from inside the unit, or is the...

    Is it leaking from inside the unit, or is the cabinet sweating?

    Which side has the problem? Left, right, front, back?
  8. Replies
    4
    Views
    483

    Could be just dirt. If you do a mold test, you...

    Could be just dirt. If you do a mold test, you should do a background test too. The best way to do a mold test is test the air inside the house with an air tester. This is a professional device that...
  9. I believe That should be a GSZ16030 outdoor...

    I believe That should be a GSZ16030 outdoor unit. I could not find any rating with that coil on the AHRI site.
  10. Replies
    3
    Views
    384

    The contactors have a mechanical interlock. They...

    The contactors have a mechanical interlock. They cannot both pull in at the same time. Someone has messed with that unit.
  11. Replies
    17
    Views
    917

    It could be too much or too little refrigerant....

    It could be too much or too little refrigerant. You need refrigerant temperatures as well as refrigerant pressures to determine proper charge. You also need indoor temperatures and outdoor...
  12. Replies
    21
    Views
    2,551

    When I was a kid we had one like that in the...

    When I was a kid we had one like that in the basement. But it was painted black on the outside. When my dad replaced it he showed all the copper coils inside. It had a modulating gas valve. We never...
  13. Replies
    4
    Views
    861

    We have been trying out Blockade from Harris with...

    We have been trying out Blockade from Harris with some success. It works best on very clean copper that fits together well. On poorly fitting joints, we use 15% silver. Blockade is much cheaper than...
  14. Replies
    48
    Views
    8,563

    Run away as fast as you can. Home warranty...

    Run away as fast as you can. Home warranty companies are nothing but trouble. I will never work for one again.
  15. I am using Digital Cool gauges. But I am looking...

    I am using Digital Cool gauges. But I am looking at the Fieldpice gauges for a second set. I have a set of analog gauges on the truck, have not used them in years. I had Testo as my first set of...
  16. Replies
    42
    Views
    5,801

    We can buy it for lot less than your Tennessee...

    We can buy it for lot less than your Tennessee price. It was over double that over a year ago. I think the drop in price is because dry units are less popular now. Demand has therefore dropped.
  17. Replies
    6
    Views
    1,436

    Put the old thermostat back on. :-)

    Put the old thermostat back on. :-)
  18. Replies
    923
    Views
    224,185

    Dude. Please don't use all caps. Add some...

    Dude. Please don't use all caps. Add some punctuation. Your post is very hard to read!
    :grin2:
  19. Replies
    27
    Views
    6,761

    I use the H10G and love it. Works better on 410a...

    I use the H10G and love it. Works better on 410a than the H10B.

    It is legal to add a little refrigerant to the nitro so your leak detector will do its job.
  20. Replies
    21
    Views
    6,617

    Now THAT is FUNNY!!! :grin2:

    Now THAT is FUNNY!!!
    :grin2:
  21. Replies
    35
    Views
    4,894

    the good lord must of invented the psychometric...

    the good lord must of invented the psychometric chart...... the next day he invented whiskey...... it really is a valuable tool ......



    After enough whiskey....it could be anything!! :angel:
  22. Replies
    7
    Views
    1,019

    You may want to check with the manufacturer....

    You may want to check with the manufacturer. someone else may have replaced the original control and changed the length already.
  23. Replies
    35
    Views
    4,894

    If you know your air flow and the Dry Bulb (DB)...

    If you know your air flow and the Dry Bulb (DB) and Wet Bulb (WB) of both the supply and return air, you can calculate your cooling capacity. If you take the readings at the supply and return...
  24. That is the way they are here too. Their name...

    That is the way they are here too. Their name used to end "Heating and Cooling". Their nickname ended "Cheating and Fooling". I stand against putting techs on commission. Just a bad idea.
  25. Replies
    16
    Views
    2,779

    My H10-G finds R410a leaks just fine. Make sure...

    My H10-G finds R410a leaks just fine. Make sure you have the G.
  26. Replies
    1
    Views
    570

    This question can not be answered in open forums....

    This question can not be answered in open forums. Get your post count up and apply for pro membership.
  27. I have tested the systems at my home and...

    I have tested the systems at my home and business. With the fan switch set to ON, the RH increases about 15%
  28. Replies
    25
    Views
    3,396

    Must be a bad TXV! Really now, start a new...

    Must be a bad TXV!

    Really now, start a new thread!
  29. Replies
    7
    Views
    1,067

    Owl Flex!

    Owl Flex!
  30. Replies
    10
    Views
    3,733

    The brighteners degrade the coil over time. They...

    The brighteners degrade the coil over time. They actually dissolve metal because they are so corrosive. If you use them, rinse for at least 20 minutes to get the residue off. Near salt air they can...
  31. Replies
    6
    Views
    938

    When you check the indoor coil and determine if...

    When you check the indoor coil and determine if it is a piston or TXV, write it down inside the service access panel outside. I use a paint marker. That saves time the next trip out.
  32. They were absorption systems. I have had it...

    They were absorption systems. I have had it explained to me. They make perfect sense....for about a day. Then you say HUH?!
    There is no mechanical compressor, and water is the refrigerant. Some...
  33. Replies
    32
    Views
    3,003

    :whistle:

    :whistle:
  34. Sell them a Service Agreement with 2 tune-ups a...

    Sell them a Service Agreement with 2 tune-ups a year. Add 3 pan pills on every tune-up as preventative maintenance.
    put some algaecide in the furnace condensate drain if you have one.
  35. Replies
    21
    Views
    6,617

    Browned butter sauce!? What is that? It sounds...

    Browned butter sauce!? What is that? It sounds yummy!
  36. Lennox says use only R-22 as a flush and capture...

    Lennox says use only R-22 as a flush and capture it in a recovery drum. I have never done that, not with the price of R-22.
  37. We had oil fill plugs on our vacuum pumps fall...

    We had oil fill plugs on our vacuum pumps fall apart. We would unscrew them to change the oil in the vacuum pump and they fell apart in your hands. Now EVERY time we use flush, the vacuum pump oil...
  38. We stopped using flush a couple of years back....

    We stopped using flush a couple of years back. Time and cost were both factors. Plus I have been told mineral oil mixes fine with poe. We have not had any problems since we switched to just blowing...
  39. Replies
    45
    Views
    4,448

    I would lose the 3M filter and replace with a...

    I would lose the 3M filter and replace with a fiberglass filter. 3M filters are very restrictive.

    Been there, what kind of ducts do you have? With good air flow you can cool below 68 degrees.
    ...
  40. Thread: Freon

    by Kevin O'Neill
    Replies
    95
    Views
    9,776

    Sounds like the OP knows how to make it, but not...

    Sounds like the OP knows how to make it, but not how to use it. :.02:
  41. I made my own excel spreadsheet. Then I got...

    I made my own excel spreadsheet. Then I got documents to go for my cell phone. I have what I need, not what I don't need.
  42. Replies
    37
    Views
    4,924

    I heard Goodman started the dry units. Then I...

    I heard Goodman started the dry units. Then I heard Nordyne started it. Our Goodman rep says Goodman was first. I don't know for sure who started it but Nordyne sells very few dry units around here....
  43. Replies
    37
    Views
    4,924

    The goodman rep in my area says he sells 2-3...

    The goodman rep in my area says he sells 2-3 times as many dry units as pink systems. That is down from 4 to 5 times as many dry units as pink systems 2 years ago.

    Just wait next January for R22...
  44. Replies
    3
    Views
    1,404

    That will not help. There is no water in the...

    That will not help. There is no water in the riser to pump.
  45. Replies
    3
    Views
    1,404

    Not enough static pressure in the water loop. You...

    Not enough static pressure in the water loop. You need to get the building owner to turn up the water pressure in the loop.
  46. Replies
    10
    Views
    1,703

    Last Ruud unit I worked on still energized the...

    Last Ruud unit I worked on still energized the reversing valve in heat. Rheem too.
  47. Replies
    22
    Views
    5,176

    Great info Mikey.

    Great info Mikey.
  48. Replies
    8
    Views
    2,793

    I stay away from the top tech motors. Carrier...

    I stay away from the top tech motors. Carrier parts is a division of Watsco, who also owns East Coast and Baker Distributors. That is a motor they get cheap. It is the store brand. I have started...
  49. Replies
    16
    Views
    3,144

    On copper to copper, no flux is needed with 15%...

    On copper to copper, no flux is needed with 15% silver solder.

    On copper to brass, per manufacturers instructions, 15% silver solder is ok, but flux must be used.
  50. Replies
    11
    Views
    2,061

    If the insulation inside the unit is wet, the pan...

    If the insulation inside the unit is wet, the pan is leaking. If just the outside of the cabinet is wet, that is sweating. Note that Carrier says pleated filters increase coil blowoff, especially on...