  1. TSC120 connecting to reliatel refrigeration module help

    I have four wires in a Trane TSC120 that was connected to a mechanical thermostat.

    100P (red) :R
    101MM (blue) :C
    175D (black) :G
    176D (Yellow) :Y1
    184A (Yellow) :Y2

    I am now connecting a...
  2. Replies
    9
    Views
    707

    Good question, I was wondering the same thing,...

    Good question, I was wondering the same thing, because it seems that there is no way to clean them.
  3. Replies
    2
    Views
    288

    Simux, Thanks for the reply and I will check...

    Simux,

    Thanks for the reply and I will check the link to see if there may be a solution to my request.
  4. Replies
    2
    Views
    288

    Tracer Summit PCMedit

    Hello,

    I was trying to locate some literature on using PCMedit and was wanting to know if anyone had a copy of a PCMedit manual that they would share.
    I have been using Tracer Summit for years...
  5. Replies
    19
    Views
    3,016

    I agree with six . This is a good thing that they...

    I agree with six . This is a good thing that they are doing.
    identifying these crooks trying to rip off people. What if these people were your family members that were being treated like this? What...
  6. Replies
    37
    Views
    4,070

    Liquid line drier

    Are you sure that you don't have two liquid line driers on this unit? One is factory installed on the inside of the panel and if you aren't looking for it can be easily missed.
  7. Thread: Elevator HVAC

    by cobitech
    Replies
    15
    Views
    5,006

    We have one RTU feeding supply air into the...

    We have one RTU feeding supply air into the elevator landings and a return air inlet at the top of the elevator shaft going back to the unit along with return air ducts from the elevator landings....
  8. Replies
    8
    Views
    1,324

    Why do you think these pressures are out of the...

    Why do you think these pressures are out of the ordinary? What is the superheat and subcooling? what is the inside and outside temperatures?
  9. Thread: Elevator HVAC

    by cobitech
    Replies
    15
    Views
    5,006

    ACFIXR, These are elevators located in our...

    ACFIXR,

    These are elevators located in our parking garage and they are extremly hot here in the deep south. I was thinking about utilizing something along the lines of a mini split and/or RV style...
  10. Thread: Elevator HVAC

    by cobitech
    Replies
    15
    Views
    5,006

    David, What type and brand of air conditioner...

    David,

    What type and brand of air conditioner did they use on the cab of the elevator?
  11. Replies
    30
    Views
    7,203

    The pictures did not post.

    The pictures did not post.
  12. Replies
    14
    Views
    827

    WHO DAT? DAT THEM SAINTS!

    I am proud of this team:patriot:
  13. Replies
    29
    Views
    1,421

    Poll: He did something Mrs. Woods did not like and...

    He did something Mrs. Woods did not like and Inquiring minds want to know.:yes:
  14. Replies
    14
    Views
    6,530

    Yes.....20" is adequate clearance. Stop worrying...

    Yes.....20" is adequate clearance.
    Stop worrying and enjoy your new home and A/C equipment.:yes:
  15. Replies
    14
    Views
    6,530

    WeatherKings are great units, same as RUUD. Your...

    WeatherKings are great units, same as RUUD. Your problem would be the unit being to close to the outside wall of your house. clearance is necessary so that your condenser can do it's job.
  16. Replies
    64
    Views
    8,348

    I wouldn't stand in water like that and work on...

    I wouldn't stand in water like that and work on something electrical.
    You will end up getting fried.:cliff:
  17. You will need to hire a professional HVAC...

    You will need to hire a professional HVAC technician to come out to your house and run a new thermostat wire and connect it properly for you.:angel:
  18. Just keep it simple. Add the larger supply...

    Just keep it simple.
    Add the larger supply register or another supply register and if its a major problem and its not.
    close down the damper while you are away.:.02:
  19. Thread: Best Pizza...

    by cobitech
    Replies
    75
    Views
    6,230

    I tried Papa Murphy's for the first time a couple...

    I tried Papa Murphy's for the first time a couple of weeks back and it was great pizza for the price and being able to take it home and cook it in your own oven was a nice change.
  20. Replies
    4
    Views
    638

    I have the SC-76 clamp on and you can use...

    I have the SC-76 clamp on and you can use accessory heads with it. Just plug them into the meter lead ends.:D
  21. Thread: Best Tool Bag

    by cobitech
    Replies
    29
    Views
    4,837

    http://www.kleintools.com/onlinecatalog/index-TOOL...

    http://www.kleintools.com/onlinecatalog/index-TOOLS.html

    I have a co-worker who has one of these and it looks durable enough with a molded bottom.

    This will be my next tool bag purchase.
  22. Replies
    50
    Views
    2,376

    It has been 18 years and it doesn't seem that...

    It has been 18 years and it doesn't seem that long ago. Time does fly when you enjoy being married.;)
  23. Replies
    14
    Views
    1,941

    OMG....... the first time I ever seen something...

    OMG....... the first time I ever seen something like that. It would be great if all of the matts would come off in one piece. LOL:p
  24. Replies
    36
    Views
    2,925

    I was thinking something along these lines. ...

    I was thinking something along these lines.

    http://www.lowes.com/lowes/lkn?action=productDetail&productId=288051-84694-DWX200&lpage=none

    It could be easily customized to fit what you want to...
  25. Replies
    16
    Views
    1,029

    You know, I didn't even like the guy from all the...

    You know, I didn't even like the guy from all the things that he has done and that I have heard about him.
    It is still a shock to hear that two of the Icons that you grew up with, have passed in...
  26. Replies
    21
    Views
    3,214

    The new precedent series package units are the...

    The new precedent series package units are the worst at having fragile condenser coils. They are not like the Voyagers at all when it comes to durability and will bend with very little water...
  27. Randell Drop-In cold pan 9700 and 9900 series

    Randell Drop In cold pan M#9957SCAT59255-1

    Has anyone had to replace a condenser fan motor on one of these before?

    It is pop Riveted from the bottom plate to the plastic motor mount.
  28. Replies
    29,807
    Views
    1,143,728

    Poll: FCS, My thoughts and prayers are with you and...

    FCS,

    My thoughts and prayers are with you and your family.

    I just recently lost a loved one to Cancer and know how hard it can be.

    God bless and I hope you beat this terrible disease.
  29. Thread: Set-N-Serve

    by cobitech
    Replies
    2
    Views
    484

    It makes sense to me what you are saying. ...

    It makes sense to me what you are saying.

    Thanks for they reply to my question.
  30. Thread: Set-N-Serve

    by cobitech
    Replies
    2
    Views
    484

    Set-N-Serve

    I was working on a set-n-serve medium temp box today and to make a long story short, I ended up changing out the cap tube feeding the evaporator.

    The question I have is that the cap tube went to...
  31. Replies
    4
    Views
    1,274

    Thanks, I didn't want to tear it up, not...

    Thanks,

    I didn't want to tear it up, not knowing how to change them.

    I will try the small screwdriver and see if I can pry the C-clip out of one.

    Thanks again for the response to my question.
  32. Replies
    4
    Views
    1,274

    C-line Hobart dishwasher float kit

    I don't normally work on dishwashers,
    However I would like to know if anyone knows how to change out the small magnetic floats in a Hobart dishwasher. #00-122674 float kit.

    Thanks,
  33. Replies
    86
    Views
    13,377

    You must be joking..........if not, go and talk...

    You must be joking..........if not, go and talk to a military recruiter.
  34. Replies
    4
    Views
    641

    Does the units in question have reliatel control...

    Does the units in question have reliatel control boards?https://www.comfortsite.com/Resources/Literature/pdf/RTSVB21AEN_0205.pdf
  35. Replies
    4
    Views
    628

    Thanks Scrooloose, I did the reset and saw...

    Thanks Scrooloose,

    I did the reset and saw that everything did go back to default.

    Thanks for the quick answer to my question.
  36. Replies
    4
    Views
    628

    Clear RAM and Reset

    What effect will it have on Tracer Summit if I do a clear Ram and reset on the BCU.

    I have a Precedent series rooftop with a Diag: SA Temp sensor Fail and am trying to reset it and it will not...
  37. Replies
    9
    Views
    1,099

    Yes,,,,,, We have changed out at least a dozen on...

    Yes,,,,,, We have changed out at least a dozen on our Trane Voyager 15-25 ton range RTU's.

    The welded seam on the heat exchanger tubes seem to be the weak point on these heat exchangers.
  38. Thread: Fan question

    by cobitech
    Replies
    21
    Views
    1,119

    My understanding of this, is that because there...

    My understanding of this,
    is that because there is no load on the motor because of the lack of air to move through the duct work due to the restricted evaporator coil,
    this would cause the amp...
  39. Replies
    136
    Views
    8,932

    Good info Key1cc, That was the kind of info...

    Good info Key1cc,

    That was the kind of info that I have been looking for myself.

    Knowing how pressure is effected by adding or removing supply and return is very helpful to understanding static...
  40. Replies
    136
    Views
    8,932

    What is your ESP with both return filters removed?

    What is your ESP with both return filters removed?
  41. Replies
    69
    Views
    8,449

    Really nice work....... one of the best that I...

    Really nice work....... one of the best that I have seen.

    Is that all sheetmetal duct?

    And you used one of those easy to clean out drain traps.

    The wiring being neatly run on top of the...
  42. Correct me if I am wrong, If amp draw goes...

    Correct me if I am wrong,

    If amp draw goes down due to restriction of air flow caused by a clogged filter or a restrictive filter, this will cause the voltage to go up and the end result will be...
  43. Replies
    0
    Views
    487

    The A-JACKS System!

    http://www.a-jacksmanufacturing.com/
  44. Replies
    8
    Views
    708

    I have run into a similiar situation before. ...

    I have run into a similiar situation before.

    The two evaporator coils being in the same box or area should be controlled by one thermostat controling both liquid line solenoid valves.

    It will...
  45. Replies
    11
    Views
    1,818

    I saw the picture from page two and there is not...

    I saw the picture from page two and there is not enough detail to really see how it works.
  46. Replies
    11
    Views
    1,818

    I have and it is no fun. I saw this article...

    I have and it is no fun.

    I saw this article and thought I would post it and ask what method others use to pull line sets?

    What is the best way to turn into the eave of the house without kinking...
  47. Replies
    11
    Views
    1,818

    Have you ever pulled a line set by yourself?

    Invention Enables One Person to Install Refrigerant Lines

    July 17, 2006


    ARTICLE TOOLSEmailPrintReprintsShare
  48. Replies
    6
    Views
    2,900

    Glad you found the problem. I read alot of...

    Glad you found the problem.

    I read alot of posts on this site about TXV failures.

    The condenser motor still needed to be changed out due to the leaking oil.
  49. Replies
    6
    Views
    2,900

    Homeless, If your condenser fan motor is...

    Homeless,

    If your condenser fan motor is leaking oil, that is not a good sign.

    Did you happen to check your amp draw on the condenser fan motor and compressor?

    What were they and what was...
  50. Replies
    8
    Views
    873

    What are you using to measure the Humidity level...

    What are you using to measure the Humidity level in your Home?

    24C is a 75°F outdoor air temp, with a thermostat setpoint of 70° and it was able to maintain a indoor temperature of 73.4°F with 75...