  1. Replies
    41
    Views
    1,359

    We have used some of the "super seal" as a last...

    We have used some of the "super seal" as a last resort, unit is not worth leak checking, to get maybe a year out of. There is no sense in leak checking a 20+ year old unit that has a small leak. ...
  2. Replies
    19
    Views
    765

    loop is too hot. You should probably do pressure...

    loop is too hot. You should probably do pressure in and pressure out to make sure the pumps are actually pumping, if there is a broken shaft the pump will still show amperage but not be pumping. ...
  3. Replies
    16
    Views
    1,294

    Talked with our ICP service rep. I am told its...

    Talked with our ICP service rep. I am told its a Copeland vendor that uses a product as a rust inhibitor, that is clogging up the TXV's. I am also told its not just an ICP problem. That if its a...
  4. Replies
    11
    Views
    2,162

    We had one do that several years ago. It was an...

    We had one do that several years ago. It was an empty building, Luckily the building next door lost part of the roof and the local fire department had the gas shut off to nearby buildings as a...
  5. Replies
    13
    Views
    1,969

    Nice looking job. Climatemaster wants you to use...

    Nice looking job. Climatemaster wants you to use a hose kit from the geo to the pumps, Its already figured in the pump sizing. We have to use purple cleaner here to. It looks bad but that's...
  6. Replies
    0
    Views
    419

    tornado damage from the Xenia 1978 storm

    I wasn't sure where to post this picture I found while looking thru some of the pictures from the 40th anniversary of the tornado. But I wanted to post this picture when I saw it. I did not...
  7. Replies
    32
    Views
    5,204

    My luck the homeowner would say, Well its only a...

    My luck the homeowner would say, Well its only a year old, Its under warranty
    right?
  8. Replies
    26
    Views
    2,940

    I understand the complaint is with the...

    I understand the complaint is with the contractor, but if I had WF literature saying it had a 10 year p&L warranty then I would be dam sure to get a 10 year p&L with it.
  9. Replies
    67
    Views
    5,383

    Sadly there is a lot of homeowners being taken by...

    Sadly there is a lot of homeowners being taken by "contractors" using scare tactics, and condemning furnaces when they are not bad. IMO that's the bad side of running a tech on sales commission. ...
  10. Replies
    67
    Views
    5,383

    Several years ago we had a customer that was...

    Several years ago we had a customer that was starting into dementia. She called every two days like clockwork and said she had no heat. We would stop by and check it. Now checking it meant...
  11. Thread: Slum Lord

    by voleye
    Replies
    30
    Views
    3,240

    I would have suggested that the gas valve be...

    I would have suggested that the gas valve be replaced. If the landlord chose not to, I would have them sign the work order saying that it should be replaced and he is taking responsibility for it. ...
  12. Thread: Sales Tactic

    by voleye
    Replies
    23
    Views
    2,161

    You have to sell yourself, the brand on the box...

    You have to sell yourself, the brand on the box is nice. But there could be multiple dealers with the same name. Pictures before and after installs, Make sure to point out what seems normal to...
  13. Replies
    20
    Views
    1,866

    We had a similar situation this winter. The HSI...

    We had a similar situation this winter. The HSI would glow and not light 4 out of 6 times. Replaced the HSI and it still would not light. Took the burners out and cleaned them, (Propane) and it...
  14. Replies
    47
    Views
    2,725

    I know they are a tad expensive. But they break...

    I know they are a tad expensive. But they break in a day or two, waterproof, and a good solid boot. Redwings 2892 I think is the number. Around $130 but you can find them on sale. They last me...
  15. Thread: Manual J / D

    by voleye
    Replies
    13
    Views
    830

    ACCA has a manual on Manual J. That's how I...

    ACCA has a manual on Manual J. That's how I learned it. Well that and dad taught me. Its nice to learn the "science" behind it, but I do everything on a computer program now in minutes
  16. Replies
    52
    Views
    3,629

    We had three of these hanging Chrysler Airtemps...

    We had three of these hanging Chrysler Airtemps in a bowling alley. Unfortunately it closed last year. But they are still there.
  17. Replies
    0
    Views
    210

    White Rodgers Duel fuel question

    We have a heat pump installed last year with propane backup. We have been using the WR touchscreen 1f95-1277 with an outdoor sensor for the balance point to control the system. The balance point...
  18. Replies
    40
    Views
    7,828

    I had no idea that's what those doors were for....

    I had no idea that's what those doors were for....
  19. Replies
    35
    Views
    5,767

    #12 charge it with frezone until its "beer can...

    #12 charge it with frezone until its "beer can cold"
  20. Replies
    24
    Views
    4,010

    I found one of these at the beginning of spring, ...

    I found one of these at the beginning of spring, This customer had pined the bush to the concrete because it looked bad from the pool. Had a blast trying to wash the condenser, and of course the...
  21. We are not allowed to use the flex connectors...

    We are not allowed to use the flex connectors like that either, We can use flex pipe, but the local inspector wants to see at least 3 feet of black iron pipe on the furnace.
  22. Replies
    26
    Views
    5,434

    I have done that in a pinch to get a unit...

    I have done that in a pinch to get a unit running, But never left it like that.
  23. Thread: top 5 brands

    by voleye
    Replies
    30
    Views
    2,568

    ICP ClimateMaster anything but trane ...

    ICP
    ClimateMaster
    anything but trane
    anything but american standard
  24. Replies
    14
    Views
    2,764

    Poll: Yes I did bump the airflow up to 550 CFM per...

    Yes I did bump the airflow up to 550 CFM per ton. It helped a little, but the first stage really dries the house out, I'm not complaining. I don't mind having to add a little humidity to the...
  25. Replies
    14
    Views
    2,764

    Poll: We have the same thing all the time here. If Im...

    We have the same thing all the time here. If Im using electric as the back up I like to size the first stage to do as close to 100% of the cooling load, and try to get the second stage as close to...
Results 1 to 25 of 404
Page 1 of 17 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event