Search:

Type: Posts; User: shaka

Page 1 of 18 1 2 3 4

Search: Search took 0.02 seconds.

  1. kitchen make up air HELP (Sizing make up air cooling)

    Got a restaurant that added a cooking grill in the middle of the restaurant to cook steaks etc.
    I informed them before they installed hood, exhaust and make up air that they will need additional AC....
  2. Replies
    17
    Views
    1,297

    did they change thier evap coil to all aluminum...

    did they change thier evap coil to all aluminum already?
    or in the prosses
  3. Thread: R-22 retrofit

    by shaka
    Replies
    31
    Views
    2,689

    this is what happens when the government gets...

    this is what happens when the government gets involve..
    I miss them old days
    12,22,502
  4. Replies
    89
    Views
    7,195

    What pissed me off the most is the AC guys always...

    What pissed me off the most is the AC guys always gets the blame..
    used to work for a school.
    1) if it rains and its leaking its probably coming from the AC
    2)Teacher burns popcorn in the lounge...
  5. Replies
    89
    Views
    7,195

    Well as TRUMP say it..........YOU FIRED!!!!! ...

    Well as TRUMP say it..........YOU FIRED!!!!!


    Just kidding...
    First of all I dont think your boss will be paying for that.
    That expensive piece of equipment has warranty or insurance.

    Your...
  6. Replies
    89
    Views
    7,195

    I think they had issues with power all along...

    I think they had issues with power all along
    Thats what probably took the compressor

    the phase monitor was probably telling you theres issues with power
  7. Replies
    89
    Views
    7,195

    So the MRI machine had no protections from power...

    So the MRI machine had no protections from power surge
    or power failure?
  8. Replies
    89
    Views
    7,195

    Something dont add up.. you said the unit was...

    Something dont add up..

    you said the unit was being protected by 3 fuse?
    What SEER rating is the condenser?
    20 amp protecting 5 ton dont sound right.

    did you ever figured out why the unit...
  9. Replies
    21
    Views
    1,682

    Grayline By the way thanks for the screw...

    Grayline


    By the way thanks for the screw driver trick
    I will use that to check plate from now on.

    I'm always learning.
    I may blow this machine up pretty soon
    But I will always be...
  10. Replies
    21
    Views
    1,682

    snapperhead The problem is the book say this...

    snapperhead


    The problem is the book say this machine will make ice in
    Approx 30 min.
    In 30 min ice is not quite ready.
    Water level in sump is still half way.

    I could move the float to...
  11. Replies
    21
    Views
    1,682

    . Ok I will check that. It seems like if...

    .


    Ok I will check that.
    It seems like if there is a separation
    There would be ice patern issue.

    Also if evap is separated
    It would make a no load or less load
    Causing suction pressures...
  12. Replies
    21
    Views
    1,682

    I haven't made it back yet I'll give update when...

    I haven't made it back yet
    I'll give update when I return.....

    It had ice from top to bottom
    In every grid.
  13. Replies
    61
    Views
    4,343

    I'll take the bad thermostat.

    I'll take the bad thermostat.
  14. Replies
    61
    Views
    4,343

    So they are giving away Class A in Florida now.?...

    So they are giving away Class A in Florida now.?

    They give it away here in Texas too
    As long as you have $500 dollars
  15. Replies
    9
    Views
    1,047

    Yes. It's line side

    Yes.
    It's line side
  16. Replies
    21
    Views
    1,682

    Initiate Harvest.

    Initiate Harvest.
  17. Replies
    21
    Views
    1,682

    float

    float
  18. Replies
    11
    Views
    663

    THATS IT....???:gah: You going to leave without...

    THATS IT....???:gah:
    You going to leave without telling us?
  19. Thread: Rx 11 question

    by shaka
    Replies
    14
    Views
    1,428

    tmech you'll be fine..... If something goes...

    tmech you'll be fine.....

    If something goes wrong, He's doomed.
    His side job.
  20. Replies
    14
    Views
    1,866

    Go back to what manufacture recomends. If you...

    Go back to what manufacture recomends.
    If you don't have that
    I usually go with
    Highest ambient (ur area) +30(convert to psi) +50

    Usually you don't need a manual reset if the system has a lock...
  21. Replies
    14
    Views
    1,866

    What is it on?

    What is it on?
  22. Replies
    14
    Views
    1,866

    Any high pressure cut out is better than none.

    Any high pressure cut out is better than none.
  23. Replies
    6
    Views
    511

    Your old 5 ton had the S circuit active also

    Your old 5 ton had the S circuit active also
  24. Thread: over charging

    by shaka
    Replies
    5
    Views
    717

    Trick question.. 0 %

    Trick question..

    0 %
  25. What ever happened to R12rules? He used to...

    What ever happened to
    R12rules?

    He used to be here all the time.
  26. Replies
    21
    Views
    1,682

    I will pull the compressor curve on this comp....

    I will pull the compressor curve on this comp.
    I'm not what else it could be
  27. Replies
    21
    Views
    1,682

    No did not have problem harvesting. I don't...

    No did not have problem harvesting.

    I don't think water inlet is leaking
    Cause I clearly remember the big tub they had behind this machine
    They are recycling the water
    Using to water...
  28. Replies
    21
    Views
    1,682

    Book 43/260 Actual 43/270 5 min. At exactly 1...

    Book 43/260
    Actual 43/270
    5 min.
    At exactly 1 hour suction is 40 psi
    And ready to harvest
    Ice thickness is a good size
    Every grid has ice

    It has a liquid line solenoid
    And pump down held
  29. Replies
    21
    Views
    1,682

    Hoshi km900MR, COMP,TXV OR HGD

    900 lbs remote
    Long freeze. Locks out on 3 beeps.

    How are you guys checking TXV.?
    Pressure swing?

    Called tech sup
    2 guys had diff opinion.

    Hot gas valve seems ok.
  30. Thread: Tachometer

    by shaka
    Replies
    19
    Views
    2,448

    I was at harbor freight The other day and I saw...

    I was at harbor freight
    The other day and I saw a tachometer.
    I was thinking of buying one just to play around with it.
    Very cheap.
  31. Replies
    77
    Views
    10,323

    My favorite tool is my HELPER. puts up ladder...

    My favorite tool is my HELPER.
    puts up ladder
    Clean my van
    Brings me water
    Cary my tools
  32. I think goodman charge it that way

    I think goodman charge it that way
  33. Replies
    34
    Views
    2,287

    Testo here also But I'm buying Sta2 hot wire

    Testo here also
    But I'm buying Sta2 hot wire
  34. How bout you sheet metal guys Don't you guys...

    How bout you sheet metal guys
    Don't you guys make a rack specially
    For coppers? I would like to see it.

    I have mine strap up with bungee
    Makes a lot of noise and it's hard to removed them....
  35. Thread: AK900's

    by shaka
    Replies
    54
    Views
    6,063

    I'm planing to buy FP Dual psychrometer where I...

    I'm planing to buy FP
    Dual psychrometer where I can check real time btu output
    But I don't want to buy that superman 4 gauges
  36. Replies
    11
    Views
    762

    Blew up. That must be the one made in Pakistan...

    Blew up.
    That must be the one made in Pakistan :grin2:
  37. Replies
    15
    Views
    1,553

    Make sure you have enough water coming in. Water...

    Make sure you have enough water coming in.
    Water volume is the key.
    Make sure you line size is big enough.
    Water inlet screen not plug
  38. Where and how do you store your roll of copper in the van

    I have my copper hanging
    Makes a lot of noise
    Need ideas on how
    And where you guys store copper
  39. Thread: AK900's

    by shaka
    Replies
    54
    Views
    6,063

    I have 3 ak900 I don't use anything else. But I...

    I have 3 ak900
    I don't use anything else.
    But I like fieldpiece wireless
    Where it can connect to air handler and give you
    Real time readings

    Digicool getting left behind
  40. Replies
    11
    Views
    762

    I can't see it

    I can't see it
  41. Replies
    16
    Views
    1,343

    I installed Psc motors also when theres an issue....

    I installed Psc motors also when theres an issue.
    X13 suppose to save them money
    Only to used all that savings on the expensive motor
  42. Replies
    16
    Views
    1,343

    Thanks I'll check with carrier Monday on...

    Thanks
    I'll check with carrier Monday on pricing and possibly carrying
    Replacement module.
  43. Replies
    21
    Views
    2,211

    Call tech supt. Make sure it's the same capacity.

    Call tech supt.
    Make sure it's the same capacity.
  44. Replies
    16
    Views
    1,343

    Regardless of Hp?

    Regardless of Hp?
  45. Replies
    16
    Views
    1,343

    Ok. So the module you Carry will work on a 1.5...

    Ok.
    So the module you Carry will work on a 1.5 ton -5 ton drive?
  46. Thread: trane rtu

    by shaka
    Replies
    22
    Views
    1,882

    Is it running? Very confusing. So is it 460...

    Is it running?
    Very confusing.

    So is it 460 or 230
  47. Replies
    16
    Views
    1,350

    Agree.. More than .5 across coil can cause it to...

    Agree.. More than .5 across coil can cause it to fly out of coil
  48. Replies
    16
    Views
    1,343

    Replacement module that you guys carry, can it go...

    Replacement module that you guys carry, can it go to any gentec
    Regardless of horse power ?

    Always thought they need go be individually programmed
  49. Thread: PACKAGED UNITS

    by shaka
    Replies
    9
    Views
    755

    No

    No
  50. Replies
    10
    Views
    950

    I usually convert it to txv and im done..

    I usually convert it to txv and im done..
Results 1 to 50 of 890
Page 1 of 18 1 2 3 4