12-24-2011, 12:43 PM
Thread: what brand water source heat pump?
by Joewf- Replies
- 9
- Views
- 5,601
Don't buy WHALEN! Reversing Valves stick all the...
Don't buy WHALEN! Reversing Valves stick all the time.
-
12-24-2011, 12:32 PM
- Replies
- 13
- Views
- 1,240
Bad Idea "Heat pumps"for elderly care facility?
Hello,
My question = are individual room water source heat pumps a good/Bad idea for a elderly care facility? given the fact that they blow cold air when they first come on because the coil does... -
04-11-2009, 11:53 AM
Thread: Hood Exhaust 24/7
by Joewf- Replies
- 4
- Views
- 772
Hood Exhaust 24/7
I have a hood exhaust over a commercial dishwasher at the facility I maintain that runs 24/7 is this normal? Shouldn't it be mechanically linked to the dishwasher control?
Old Maintenance Man -
04-11-2009, 10:18 AM
Thread: Reversing Valve Problems
by Joewf- Replies
- 6
- Views
- 3,279
Reversing Valve Problems
To the pros,
Have any of you guys ever had problems with reversing valves getting stuck in either cooling or heating on heat pumps? I have 26 Whalen Heat Pumps which are heat active (meaning... -
03-28-2009, 10:25 PM
Thread: Walkin Freezer Question
by Joewf- Replies
- 8
- Views
- 621
Thanks for all your replys. The Box measures...
Thanks for all your replys.
The Box measures 10' 7" X 9' 4" with a ceiling hight of 8' 7"to be exact.
The temp is kept around zero to minus 10
Has one door which opens into the kitchen
... -
03-25-2009, 11:03 PM
Thread: Walkin Freezer Question
by Joewf- Replies
- 8
- Views
- 621
Walkin Freezer Question
Hello,
I work in facilities maintenance as a supervisor and presently involved in replacing a built in walkin freezer in our kitchen facility. I have obtained two bids from two differant... -
02-21-2009, 12:15 PM
Thread: old coleman furnace
by Joewf- Replies
- 3
- Views
- 367
old coleman furnace
I have a coleman furnace which runs on LP gas. The problem I have been having is the pilot light will not stay on. I replaced the thermocouple and it worked fine for about a week and a half. I...
-
02-21-2009, 11:19 AM
Thread: old coleman furnace
by Joewf- Replies
- 1
- Views
- 276
old coleman furnace
I have a coleman furnace which runs on LP gas. The problem I have been having is the pilot light will not stay on. I replaced the thermocouple and it worked fine for about a week and a half. I...
-
02-02-2009, 09:49 PM
Thread: rooftop exhaust question
by Joewf- Replies
- 6
- Views
- 375
No mushroom cap just ducted straight up.
No mushroom cap just ducted straight up.
-
02-02-2009, 03:47 PM
Thread: rooftop exhaust question
by Joewf- Replies
- 6
- Views
- 375
rooftop exhaust question
I maintain a 26 room carecenter facility with a rooftop exhaust system which is ducted to each rooms bathroom. I took over this facility after a complete remodel in 2004. Last week a power outage...
-
06-16-2008, 10:38 PM
Thread: Join office and warehouse
by Joewf- Replies
- 6
- Views
- 660
I don't really understand what your saying, you...
I don't really understand what your saying, you have 1/3 office space with A/C, and 2/3 warehouse (studio) with only heat. You want to tap two supply registers and bring them into the warehouse to...
-
06-15-2008, 11:20 AM
Thread: Best walk-in freezer/coolers on market
by Joewf- Replies
- 2
- Views
- 621
Best walk-in freezer/coolers on market
I need to replace two walk-in coolers and one walk-in freezer which were installed with the coolers on each side and the freezer in the middle each having its own door which opens into our commercial...
-
06-15-2008, 10:51 AM
Thread: Join office and warehouse
by Joewf- Replies
- 6
- Views
- 660
Tapping two supply registers into the warehouse...
Tapping two supply registers into the warehouse section might help take the edge off but if you put in a return like a transfer grill then your pulling warm/hot warehouse air into the office which...
-
06-14-2008, 02:03 PM
Thread: Reversing valves
by Joewf- Replies
- 2
- Views
- 492
Reversing valves
Hello,
I'm a maintenance mechanic with a working knowledge of HVAC. One building in my facility is a 26 bed carecenter for the elderly with each room having its own water cooled heat pump. These... -
05-16-2008, 02:51 PM
Thread: Whalen Heat Pumps
by Joewf- Replies
- 2
- Views
- 812
Whalen Heat Pumps
Hello,
Has anyone ever worked on Whalen water source heat pumps? They are the chassis style which can be changed out by disconnecting the water inlet/outlet hoses and electrical connection then... -
03-16-2008, 01:58 PM
Thread: Metysis DX9100
by Joewf- Replies
- 5
- Views
- 896
Metysis DX9100
I have a Metysis DX9100 controller that controls a Air Handler Unit which has a chilled water coil and a Hot water coil. When in the "Unoccupied Mode" the sequence of operation calls for the fan to...