    VERY. (good luck, ball valves, not gonna happen...

    VERY. (good luck, ball valves, not gonna happen $$$$$$). Most drain lines down here are common to a few units, we hook a vacuum hose up to them and get as much out as possible. (most have traps and...
  2. Replies
    18
    Views
    515

    you didn't say if it was hor/vert or the make. So...

    you didn't say if it was hor/vert or the make. So I would pull the door and poor water in the pan. then watch it flow. I have found units unlevel (even level. you have to help Lennox hor.) Also have...
  3. Replies
    6
    Views
    238

    X2 insulate both and try to come over the top of...

    X2 insulate both and try to come over the top of AH unit to make a natural trap to ensure oil return.
  4. Thread: New to service

    by Tech83
    Replies
    17
    Views
    614

    I agree with Carmen. that being said , I have had...

    I agree with Carmen. that being said , I have had to do this for many years. Run the heat in the house to get a little load while you are checking out everything else. Then wrap the condenser with a...
  5. Replies
    7
    Views
    417

    Many questions to ask yourself. How old is unit?...

    Many questions to ask yourself. How old is unit? How long will repair take under a slight positive pressure? Location of dryer? Like Birm said if its a simple change under positive pressure, leave...
  6. Replies
    18
    Views
    978

    I thought oxy and nitro threads were different...

    I thought oxy and nitro threads were different ie.. 1 left thread and 1 right, so they didn't get mixed or crossed up in hospital use!
  7. You said you replaced the compressor once before...

    You said you replaced the compressor once before , by chance did you add a trap to help get the oil back to the new compressor. also I would look at increasing your blower speed, not knowing the lay...
  8. Replies
    13
    Views
    1,130

    Is the Java the correct version?

    Is the Java the correct version?
  9. Replies
    13
    Views
    1,130

    Did you do all upgrades before installing...

    Did you do all upgrades before installing 5.2.10? I think there were patches that needed to be done before upgrade.
  10. Replies
    21
    Views
    1,026

    I just replaced a header coil on a unit that was...

    I just replaced a header coil on a unit that was 10 months old. Tubes were freezing within minutes, second stage would kick in and satisfy stat. Header was soaked. Carrier has had an issue with...
  11. Replies
    6
    Views
    595

    Power issues

    I have had to have electricians move taps on the transformer after doing a electrical input mapping over a period of a couple of days. what we found was Elec comp. would jack up voltage as demand...