  1. Replies
    14
    Views
    384

    Here is a screenshot of the cut sheet. ...

    Here is a screenshot of the cut sheet.

    http://imgur.com/FRraoIR
  2. Replies
    14
    Views
    384

    They're Daikin. I don't have the equipment...

    They're Daikin. I don't have the equipment submittal right now as i'm on my home computer but the smallest one is 2.8 ft pressure drop, which is less than 1 PSI I believe. Some HP manufacturers (FHP)...
  3. Replies
    14
    Views
    384

    Ha, my mistake! I thought you were inferring that...

    Ha, my mistake! I thought you were inferring that I was the engineer. Yes I totally agree. Some of the specs we get are copy pasta from the early 2000's. "Minimum PC requirement Windows 98" It's...
  4. Replies
    14
    Views
    384

    I'm sorry, could you elaborate on this statement?...

    I'm sorry, could you elaborate on this statement? Not sure how you came up with that.
  5. Replies
    14
    Views
    384

    WSHP DP switch

    Hello,

    I have a project with water source heat pumps where a differential pressure switch is specified to proove flow through the condensor coil. The pressure drops of the coils are very low, some...
  6. Replies
    157
    Views
    26,993

    Could someone please send me the D-BACs...

    Could someone please send me the D-BACs application? Email is in my profile, Thanks!
  7. Replies
    5
    Views
    430

    I appreciate the help but i've tried connecting...

    I appreciate the help but i've tried connecting to this controller over a browser. No dice. I know the IP address and instance number but have no way to change them.

    This manual is for a chiller...
  8. Replies
    5
    Views
    430

    Awesome..can you elaborate? Everything i've read...

    Awesome..can you elaborate? Everything i've read so far says you need the McQuay service tools.
  9. Replies
    5
    Views
    430

    McQuay Microtech 2 BACnet IP

    I have 5 packaged RTU's that have incorrect (maybe the default) IP addresses and BACnet instance numbers. Does anyone know if these parameters can be accessed/edited via the keypad display? If not...
  10. Replies
    8
    Views
    1,005

    Are you using a 3rd party driver or Schneider's?

    Are you using a 3rd party driver or Schneider's?
  11. Replies
    5
    Views
    1,323

    Ok so I discovered that the Cbus card in the CPU...

    Ok so I discovered that the Cbus card in the CPU was the problem. I swapped the card with the one that WAS working and sure enough it worked fine. Got a new XD505a card and all is good. Thanks for...
  12. Replies
    5
    Views
    1,323

    Thanks for the reply Keith. I'm connected...

    Thanks for the reply Keith. I'm connected directly to the Cbus using an Infocon Easy IO Sedona controller that is flashed specifically for Cbus. The jace is talking to the Easy IO gateway via Cbus...
  13. Replies
    5
    Views
    1,323

    Honeywell XC5010

    Trying to integrate two of these panels to a Jace-6 using infocon's cbus driver and an easy IO gateway. I'm able to discover both panels and a point discovery in one of them works fine. All the...
  14. Replies
    7
    Views
    1,237

    I believe there is one for space temp control and...

    I believe there is one for space temp control and one for discharge air control. I would need the space temp control one but would certainly appreciate you sending both.

    I registerd on the Newron...
  15. Replies
    7
    Views
    1,237

    Trane LCI-R lon card commission Fail (AX)

    Pulling out an NAE and replacing with an FX-70.Trying to get 4 Trane LCI-R lon intergration cards commissioned in AX and get a "sendNormal" error (see attached). My guess is that the cards were...
  16. Replies
    2
    Views
    356

    Pretty sure I can help you out..Email is in my...

    Pretty sure I can help you out..Email is in my profile
  17. Replies
    18
    Views
    2,516

    It is my understanding that user privileges in...

    It is my understanding that user privileges in Insight are based on the Windows user account privileges. Is this incorrect?
  18. Replies
    18
    Views
    2,516

    Thanks for all the replies. P1nda that would be...

    Thanks for all the replies. P1nda that would be fantastic if you could provide me with any documentation for Insight 3.6. My email is in my profile.

    Randy, Thank you very much for taking the time...
  19. Replies
    18
    Views
    2,516

    The PC is owned by the county (not Siemens) and...

    The PC is owned by the county (not Siemens) and is not on any network. Completely stand alone, nothing even plugged into the Ethernet jack. It was setup by Siemens and there is absolutely only one...
  20. Replies
    18
    Views
    2,516

    Thanks for the reply. It is an XP pro machine...

    Thanks for the reply. It is an XP pro machine with SP2. I'll definitely try what you suggested but I'm still interested in restoring a backup in case something goes wrong and I do have to re-install...
  21. Replies
    18
    Views
    2,516

    Siemens Insight 3.6

    I have a customer that has a building with Siemens controllers and an Insight front end. Siemens setup the PC user account for the customer (a county superior courthouse) with no admin rights, thus...
  22. Thread: test

    by matt8085
    Replies
    0
    Views
    315

    test

    .
  23. Replies
    13
    Views
    1,666

    Could you send this my way as well? matt8085 at...

    Could you send this my way as well? matt8085 at yahoo dot com

    It would be much appreciated.
  24. Replies
    13
    Views
    741

    LOL!!!!!

    LOL!!!!!
  25. Replies
    13
    Views
    1,666

    Would you care to share?

    Would you care to share?