Search:

Type: Posts; User: thump_rrr

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Thread: Work Pants

    by thump_rrr
    Replies
    32
    Views
    1,880

    I wear 5.1.1 Tactical Tac Lite Pro Pants. Plenty...

    I wear 5.1.1 Tactical Tac Lite Pro Pants.
    Plenty of pockets including a cell phone pocket and a pocket for pens.
    Very breathable, they dry in 20 minutes when caught in the rain.
    The knees are...
  2. I have installed quite a few Gree ductless mini...

    I have installed quite a few Gree ductless mini splits and I can guarantee you that they are not stealing any American technology.
    Their units are very well made and light years ahead of any...
  3. Replies
    7
    Views
    689

    Where in the coil is it? If it is next to the...

    Where in the coil is it?
    If it is next to the tube sheet I use a 1/8" aircraft drill bit to drill holes in the tubesheet around the tube in question.
    I then cutout the tube sheet before brazing.
  4. Replies
    21
    Views
    1,605

    I have the Klein CL2100 which has true RMS and...

    I have the Klein CL2100 which has true RMS and the built in thermocouple.
    I purchased it after my truck was broken into and $6,000 worth of tools were stolen including 3 Fluke meters.

    I needed to...
  5. Replies
    34
    Views
    3,336

    I use a Surefire 6PX Pro. It uses 2 CR134...

    I use a Surefire 6PX Pro.
    It uses 2 CR134 batteries.
    It has 2 intensities 15 lumen and 200 lumen.
    Not the cheapest flashlight or batteries but I can usually buy a box of 12 genuine surefire for...
  6. Replies
    15
    Views
    1,233

    This isn't the open forum section if I'm not...

    This isn't the open forum section if I'm not mistaken.

    In the last 25 years I've only had 1 Carlyle 06D/E series compressor run low oil pressure on me.
    I deal with a local rebuild shop who sells...
  7. Replies
    25
    Views
    3,460

    I prefer a rib steak but those are some nicely...

    I prefer a rib steak but those are some nicely marbled pieces of tasty goodness .
  8. I'm in Montreal and I've opened them up in the...

    I'm in Montreal and I've opened them up in the winter to find frost covering the interior of the disconnect.
    You then get the sun coming out and melting the frost directly into the terminals.
    ...
  9. Replies
    21
    Views
    1,453

    What is the return air wetbulb temp? If you...

    What is the return air wetbulb temp?

    If you also had return air wetbulb you could check if the airflow is too high causing the high supply temp.
  10. The question is did you find the cause? It just...

    The question is did you find the cause?
    It just doesn't happen because it felt like it.

    To elaborate a litre more in our Canadian climate what usuly happens is that the electrician doesn't use...
  11. Replies
    225
    Views
    43,941

    Sticky: Poll: American Standard, Payne. Up here you must buy...

    American Standard, Payne.
    Up here you must buy into the advertising for Bryant or Trane.
    We are primarily a commercial, industrial contractor so residential is a tiny part of our business.
    As far...
  12. Replies
    24
    Views
    2,066

    What does it cost to haul a 19,000 lb cooling...

    What does it cost to haul a 19,000 lb cooling tower to your shop and have it placed somewhere out of the way?
    It sure isn't free neither is the equipment used to lift it.
    You then need to bring...
  13. Thread: H-10

    by thump_rrr
    Replies
    9
    Views
    699

    If you're not familiar with it take note that you...

    If you're not familiar with it take note that you cannot run the H10-PM on the power adapter unless it is the larger one which I believe is 1700va.
  14. Replies
    32
    Views
    2,704

    I have an H10PM with both transformers. The...

    I have an H10PM with both transformers.
    The small one can only charge the unit while the larger one can either run or charge the unit while plugged in.

    I only plug it in to charge when the low...
  15. What were the high side and low side pressures?...

    What were the high side and low side pressures?
    What was the return air wet bulb temperature
    What was the superheat at the compressor?
    Some of the things that we need to know to diagnose a system.
  16. My thoughts are that you did well going for a YJ....

    My thoughts are that you did well going for a YJ.
    I bought a Supco and somehow lost it a month later.
    That was the best thing that could have ever happened to me.

    Which YJ vacuum gauge did you...
  17. As valdelocc has already mentioned the low...

    As valdelocc has already mentioned the low voltage indicates that the 24v has dropped below 19.2v.
    Typically you get a low voltage with a high current draw so you need to find out what is drawing...
  18. I've changed probably 6 of those universal joints...

    I've changed probably 6 of those universal joints in the last 8 years.
    If they are seized I just take a cutting disc on a grinder and cut a slot in the u joint almost all the way to the shaft.
    I...
  19. I used the 1/4" npt fitting on the bottle along...

    I used the 1/4" npt fitting on the bottle along with the 3/4" npt pipe plug that was there for the safety shutoff.
    I didn't use the high or low side fittings.
    If I had another 3/4"npt x 1/2" flare...
  20. Replies
    24
    Views
    2,066

    Nobody will touch it without the copper in it. ...

    Nobody will touch it without the copper in it.

    I had a hard time finding a scrap guy to come take 6 tons of cast iron boiler sections.

    A technician including the cost of his truck and benefits...
  21. Pics posted of blower section

    This is what the other tech found.
    Sorry for the crappy cellphone pics.
    http://i24.photobucket.com/albums/c40/Thump_rrr/6C327A80-96AE-4D00-B8B0-60460FBA8226-3911-000005B1548CA17B_zps8a9c0618.jpg...
  22. The evaporator was a block of ice when it was...

    The evaporator was a block of ice when it was found.
  23. Over a litre to date. The circuit was open for...

    Over a litre to date.
    The circuit was open for about 3 weeks before we got the call.

    I will post pictures later of what the blower section looked like when we got there.
  24. No frosty parts on the unit. The unit is a...

    No frosty parts on the unit.
    The unit is a packaged rooftop air conditioner with 2 20 ton circuits.
    It has air cooled condensers and DX cooling.
    The blower section came apart braking the...
  25. Replies
    35
    Views
    2,474

    In Canada or at least in Quebec where I am if I...

    In Canada or at least in Quebec where I am if I modify a gas line for example add an additional suspended furnace.
    I am responsible for the entire gas line being up to current code.
    This means that...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4