Search:

Type: Posts; User: nickellhead

Page 1 of 11 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    27
    Views
    2,778

    No not normal at all!! If you just had it...

    No not normal at all!! If you just had it installed have them come back to fix it.
  2. Replies
    27
    Views
    2,778

    Sounds like squirrel cage rubbing on housing on...

    Sounds like squirrel cage rubbing on housing on start up
  3. Replies
    26
    Views
    3,239

    I let it run for awhile and I ended up putting a...

    I let it run for awhile and I ended up putting a total of 14oz in. The cabinet got down to 38 degrees before I left. Comp would cycle on and starting pressures were 21/165 and it would run for a...
  4. Replies
    26
    Views
    3,239

    Also line temp 12" from comp is 84 degrees making...

    Also line temp 12" from comp is 84 degrees making it 90 degree super heat
  5. Replies
    26
    Views
    3,239

    Ok. I cut 10" off cap tube. Purged with nitro....

    Ok. I cut 10" off cap tube. Purged with nitro. Weighted charge back in. My suction psi is 3psi and head is 125psi. My cabinet is 65 degrees and ambient is 85 degrees. System calls for 11oz and I...
  6. Replies
    26
    Views
    3,239

    Thanks everyone! I will go there this evening and...

    Thanks everyone! I will go there this evening and check all of that. Why does cap tube have to be strapped to suction line?
  7. Replies
    26
    Views
    3,239

    Thanks 2sac! That may be the problem. Because its...

    Thanks 2sac! That may be the problem. Because its lasted all week and then it sees to freeze up the day after they've been closed for two days. I'll definitely check that out!! I know my head...
  8. Replies
    26
    Views
    3,239

    I think their taking the pans out at night. Why...

    I think their taking the pans out at night. Why does it matter if pans are in there? I will check and clean Condensor tomorrow. Thanks for all your help!! If you think of anything else please let me...
  9. Replies
    26
    Views
    3,239

    When I weighted it in I let it cool down but...

    When I weighted it in I let it cool down but suction pressure nor head changed. It stayed at 3-4&160ish. And it took cabinet forever to get down to 38 degrees. I just don't understand how it's...
  10. Replies
    26
    Views
    3,239

    When I first weighted it in my suction was at...

    When I first weighted it in my suction was at 3-4psi. That's why I overcharged. Shouldn't my suction on a refrigerator with 134 be around 25 psi?
  11. Replies
    26
    Views
    3,239

    11oz. It's a True TSSU 48-12

    11oz. It's a True TSSU 48-12
  12. Replies
    26
    Views
    3,239

    I overcharged it about 4-6oz to get suction up....

    I overcharged it about 4-6oz to get suction up. I'm wondering if I need to shorten length of cap tube to raise suction pressure. It ran good for a week but now froze up again.
  13. Replies
    26
    Views
    3,239

    True prep table

    I've been working on older true prep table. The evaporator keeps freezing up. I've replaced the cap tube with same size and length and dryer. Ive brazed in access fittings on high and low it's a...
  14. Replies
    12
    Views
    2,885

    To adjust the logic board. The left potentiometer...

    To adjust the logic board. The left potentiometer (mix) controls the hopper temp. The middle potentiometer controls the barrel viscosity when in auto. And the right potentiometer controls barrel temp...
  15. Replies
    12
    Views
    2,885

    Ash, I just seen your post. Have you checked your...

    Ash, I just seen your post. Have you checked your belt tension? Also check the drive coupling in the back. Sometimes the set screws come loose and they'll turn for a little while and then slide back...
  16. I've seen this a lot and it's usually a corroded...

    I've seen this a lot and it's usually a corroded terminal on compressor not holding wire terminal on anymore.
  17. Replies
    18
    Views
    1,936

    I use the makita 1/2" hammer drill. They've...

    I use the makita 1/2" hammer drill. They've seemed to last awhile. I also use the makita mini impact. Nice and handy.
  18. Replies
    12
    Views
    2,885

    The two bolts with springs on the metal bracket...

    The two bolts with springs on the metal bracket that holds your motor is for your belt tension. They should be 1/2" bolts with 1/2" nuts. You tighten those down evenly till you have about 1/2" play...
  19. I'd say the customer meant it was tripping the...

    I'd say the customer meant it was tripping the high limit. It would've been interesting to have seen the condensation line plug up and run down onto strip lol
  20. Replies
    3
    Views
    438

    Thanks! The reason I ask about the cap rating is...

    Thanks! The reason I ask about the cap rating is cause I was on a service call of an airflow unit that was only 3 years old and cap was blown already. It was covered in rust and comp didn't have...
  21. Electric!!

    Electric!!
  22. Replies
    3
    Views
    438

    Helpful tips

    Is there any helpful apps for an I-phone? And also is there any links to help you find the right size capacitor during after hour calls when old one is covered in rust?

    Thanks!
  23. Thread: Taylor 336

    by nickellhead
    Replies
    13
    Views
    3,063

    If the beater motors continue to run you can...

    If the beater motors continue to run you can change that on the logic board
  24. Thread: Taylor 336

    by nickellhead
    Replies
    13
    Views
    3,063

    The beater motors will always run when comp is...

    The beater motors will always run when comp is on. The beads are a seperation of product which is caused from overbeating. Overbeating is usually caused from bad scraper blades or poor sales.
  25. Thread: Taylor 336

    by nickellhead
    Replies
    13
    Views
    3,063

    Priming is the process of putting the mix in....

    Priming is the process of putting the mix in. Take the tubes out of hopper, pour mix in, lift prime plug until mix spews out, put tubes back in hopper, and than put into auto.
Results 1 to 25 of 259