04-12-2013, 06:51 PM
- Replies
- 17
- Views
- 644
No, upflow. Wierd I know, but it fixed it in...
No, upflow. Wierd I know, but it fixed it in this case.
-
04-12-2013, 05:34 PM
- Replies
- 17
- Views
- 644
Tstat isn't wired wrong so strip heat runs at the...
Tstat isn't wired wrong so strip heat runs at the same time as the heat pump, right? I just fixed one that had been there for ten years with that problem. Customer had been told the HP switch was a...
-
12-06-2012, 12:01 PM
Thread: New gas line..
by gasser65- Replies
- 8
- Views
- 583
American Copper and Brass sells "Anvil" ...
American Copper and Brass sells "Anvil" brand www.acandb.com
Leran sells "Ward" brand www.e-leran.com
We've used both brands for years... -
11-29-2012, 02:01 PM
- Replies
- 12
- Views
- 1,147
All that I've installed have a manual "on, off,...
All that I've installed have a manual "on, off, remote" button on the remote box, you should be able to operate the fireplace with or without a remote.
-
11-28-2012, 04:49 PM
Thread: Static pressure testing
by gasser65- Replies
- 73
- Views
- 7,156
The number one thing that checking static...
The number one thing that checking static pressure has helped me with is fixing condensation problems. Almost all the horizontal attic units that I've seen with a pan full of water under them have...
-
06-29-2011, 05:23 PM
Thread: Hot in Texas
by gasser65- Replies
- 26
- Views
- 1,326
Elbows are ok - they are insulated aren't they. ...
Elbows are ok - they are insulated aren't they. Ductboard triangles are not very good even if they aren't leaking. I'd get a reputable company to re- work your duct system and seal it up correctly.
-
06-13-2011, 06:04 PM
- Replies
- 61
- Views
- 4,079
Two 16x25 equals about 1100 cfm. A five ton is...
Two 16x25 equals about 1100 cfm. A five ton is capable of producing about 2000 cfm. Maybe it is pulling in more dirt because it is sucking so hard through returns that are too small.
-
05-19-2011, 02:55 PM
Thread: Cordless shears
by gasser65- Replies
- 6
- Views
- 845
Check this out: ...
Check this out: ...
-
05-12-2011, 01:39 PM
Thread: Fieldpiece SC56
by gasser65- Replies
- 6
- Views
- 820
Fieldpiece SC56
Does this meter have a magnet for attaching it to a unit, breaker box, etc.?
-
05-06-2011, 05:43 PM
Thread: low charge
by gasser65- Replies
- 6
- Views
- 1,436
No cooling and excess condensate from ice buildup.
No cooling and excess condensate from ice buildup.
-
05-06-2011, 01:02 PM
Thread: Propane and oxy
by gasser65- Replies
- 5
- Views
- 860
If you use propane with a 1# tank, check this out...
If you use propane with a 1# tank, check this out it's refillable
http://www.mantank.com/newsletters/1lb.html -
03-08-2011, 05:30 PM
Thread: Empire Vent material
by gasser65- Replies
- 1
- Views
- 864
Empire Vent material
Does anyone have a reliable vendor for "Direct Vent" venting materials for Empire brand DV Fireplaces? Both my vendors have stopped carrying Empire and they can't even tell me who to call to get...
-
03-03-2011, 01:02 PM
- Replies
- 22
- Views
- 1,141
I'd call your installer back or maybe another...
I'd call your installer back or maybe another service tech familiar with the type of unit you have to see what is going on then.
-
03-03-2011, 12:48 PM
- Replies
- 22
- Views
- 1,141
Does the outside unit run when you turn the...
Does the outside unit run when you turn the thermostat to "heat on". If not, the emergency / gas heat is providing all the heat - which will cause you to use more gas.
-
02-03-2011, 03:11 PM
Thread: Smelling gas near LP tank is normal?
by gasser65- Replies
- 32
- Views
- 3,556
You should be due a credit on your account if the...
You should be due a credit on your account if the tank is owned by your gas provider. I usually will credit our customers a minimum of 25 gallons worth if one of our company owned tanks develops a...
-
02-03-2011, 12:44 PM
Thread: Smelling gas near LP tank is normal?
by gasser65- Replies
- 32
- Views
- 3,556
I own a propane company. Your provider is not...
I own a propane company. Your provider is not following the proper protocol in this situation. If one of our customers calls and says they smell gas, we get there as quick as we can after advising...
-
01-14-2011, 04:31 PM
Thread: Propane Heater w/24V controls
by gasser65- Replies
- 11
- Views
- 595
We've sold propane heaters for many years - they...
We've sold propane heaters for many years - they do not make a propane space heater w/24V controls as far as I know. Why not just use the space heater as the heat source when you need it and turn on...
-
01-03-2011, 02:04 PM
Thread: Propane usage.
by gasser65- Replies
- 9
- Views
- 719
I am a propane supplier, here is what we see that...
I am a propane supplier, here is what we see that causes excessive gas usage most often: 1)Leaking valves or gauge on the propane tank. 2)Regulators venting gas. 3)Leaking underground gas...
-
12-01-2010, 03:55 PM
Thread: propane furnace delayed ignition
by gasser65- Replies
- 47
- Views
- 3,211
I know the rules, what part of my post do you...
I know the rules, what part of my post do you consider DIY?
-
11-30-2010, 05:05 PM
Thread: propane furnace delayed ignition
by gasser65- Replies
- 47
- Views
- 3,211
If the gas flex connector is one of the old gray...
If the gas flex connector is one of the old gray coated brass ones, you need to replace it. We see those old ones crack and leak quite often. Also, the flex connector isn't supposed to be inside...
-
10-29-2010, 05:54 PM
Thread: Payne thoughts - and upsizing coils?
by gasser65- Replies
- 16
- Views
- 1,094
You don't say what Carrier units we are comparing...
You don't say what Carrier units we are comparing to the Payne units, so I can't say for sure, but... most Carrier outside units have more protection covering the outside coil, i.e. "louvered cases"....
-
06-03-2010, 03:35 PM
Thread: Coil freezes up
by gasser65- Replies
- 9
- Views
- 1,189
You don't have a lot of your registers closed in...
You don't have a lot of your registers closed in rooms you don't use or something like that do you?
-
04-12-2010, 05:18 PM
Thread: Payne heat pump problem
by gasser65- Replies
- 12
- Views
- 924
I've seen mercury in the old mercury bulb tstats...
I've seen mercury in the old mercury bulb tstats bounce back and forth on startup and freak out the time delay in the condenser, but never on three units in the same house and usually the condenser...
-
04-07-2010, 05:46 PM
Thread: 50,000lb/day Ice Machine
by gasser65- Replies
- 19
- Views
- 3,599
That's a lot of ice! That propane bottle in the...
That's a lot of ice! That propane bottle in the pictures really shouldn't be in an enclosed area - if the relief valve vents it could make a real big bang.
-
01-06-2010, 05:42 PM
- Replies
- 36
- Views
- 2,991
Gas inlet, condensate drain outlet and electrical...
Gas inlet, condensate drain outlet and electrical inlet are all on the outside of the unit - you will probably want to hide those somehow so the install doesn't look bad. Depends on your roof...
Results 1 to 25 of 220