    I really can't say if the sizing is right since I...

    I really can't say if the sizing is right since I have not seen the job. I would recommend going with the 12seer ac since your average summer temp is 88. I don't think if you went any better with...
  2. Replies
    2
    Views
    867

    First as far as the furnace being big enough, I...

    First as far as the furnace being big enough, I really can't say. I can tell you this, a 100,000btu furnace at 81% efficiency delivers 81,000btu, a 80,000btu at 93% effieciency delivers 74,400btu.
    ...
  3. Thread: Goodman GMV9

    by tpr
    Replies
    15
    Views
    1,820

    I still think the Goodman are junk. If you want...

    I still think the Goodman are junk. If you want a excellent furnace, go with a Rheem. Rheem also has the quitest line of furnaces. The Rheem Mod90 is the only furnace that has a variable gas...
  4. Replies
    29
    Views
    6,428

    It looks really nice. In the future you could...

    It looks really nice. In the future you could just make a transition to the size of the 3 ducts combined and just nest the 3 ducts coming off together. It will save you time and material and...
  5. Replies
    25
    Views
    7,659

    Who bent the conduit? Tom

    Who bent the conduit?

    Tom
  6. Thread: Repost! Furn & Air

    by tpr
    Replies
    37
    Views
    4,901

    If air is blowing through the trap, why will a...

    If air is blowing through the trap, why will a trap fill with water and get clogged with debris on a upflow furnace. Placement of the trap by the manufacturer can actually create a small suction...
  7. Thread: Repost! Furn & Air

    by tpr
    Replies
    37
    Views
    4,901

    I noticed above you said you do not need a trap...

    I noticed above you said you do not need a trap on a upflow. First time I heard that. Every AC I install calls for a trap on the evaporator coil. Think about it, if you run a condensate to a drain...
  8. Thread: Repost! Furn & Air

    by tpr
    Replies
    37
    Views
    4,901

    I don't know why it's not showing my credentials....

    I don't know why it's not showing my credentials. I signed up as a professional. My business is located near Cleveland Ohio.

    As far as the elctrical goes, I think they changed the code...
  9. Thread: Repost! Furn & Air

    by tpr
    Replies
    37
    Views
    4,901

    You need to go and check the NEC book. If the...

    You need to go and check the NEC book. If the breaker panel is not visible, you must have a means of disconnect. A 15amp switch is not a disconnect. Since you didn't know about that you probably...
  10. Thread: Repost! Furn & Air

    by tpr
    Replies
    37
    Views
    4,901

    Keep trying, duct looks good though. Things to...

    Keep trying, duct looks good though. Things to work on: No trap on condensate, furnace should be raised of the floor, and no chimney liner. Combustion air may be fine as long as sqft of the area...