  1. Jeep has you on the right track. Might also clamp...

    Jeep has you on the right track. Might also clamp amp around brown wire going to solid state viscosty control (if equiped) should read 80% of beater motor amp at shut off. Short cycling is usually...
  2. Replies
    7
    Views
    884

    Lockout history will tell you why.If it was...

    Lockout history will tell you why.If it was during heat cycle check in heat cycle data. Normal causes are low glycol,glycol pump or clogged filter, agitator paddle in hopper turning slow,bad heater,...
  3. Replies
    52
    Views
    2,645

    dennis, the cabonated water does not go through...

    dennis, the cabonated water does not go through any copper tubing does it?
  4. Replies
    52
    Views
    2,645

    I know that water supply to carbonator should not...

    I know that water supply to carbonator should not go through phosphate filter. Only filter used is carbon and large particle. Not sure about softner.
  5. Replies
    28
    Views
    2,809

    T-stat set correctly Evap clean,no bent fins...

    T-stat set correctly
    Evap clean,no bent fins good airflow etc...
    Condensor clean aiflow etc...
    Heat,super and subcooling.
    TECH method works on most refrigeration
  6. Replies
    11
    Views
    1,093

    I agree with coldmilk but will try out what...

    I agree with coldmilk but will try out what Lusker said.
  7. Replies
    26
    Views
    2,014

    according to the three stooges-Althouse...

    according to the three stooges-Althouse /Turenquist/Bracciano. There are several theories concerning the principal of operaton of the capillry tube. The tube resist fluid flow. Pressure goes down as...
  8. Thread: Thermo King

    by taylortech
    Replies
    3
    Views
    909

    whats a sentance?

    whats a sentance?
  9. Replies
    11
    Views
    1,183

    Anyone try it? Have a small cabinet refer that I...

    Anyone try it? Have a small cabinet refer that I would like to pick up some efficiency. Also have to many plugged cap tubes lately.
  10. Replies
    3
    Views
    949

    standby t-stat is only used in standby. Check...

    standby t-stat is only used in standby. Check off cycle timer. When handle is NOT pulled it will cycle unit every 14 min. There should be no compressor delay when handle is pulled.
  11. Replies
    16
    Views
    1,389

    It would be hard to tell with no access port....

    It would be hard to tell with no access port. Shotgun the filter, cap tube and CPR. Taylor uses a CPR with AXV in older semi units. Usually scrap it when installing herm comp.
  12. Replies
    3
    Views
    708

    I would have to say beater amp...kinda. When...

    I would have to say beater amp...kinda. When handle is pulled they pulse and split the refrigeration say 90/10 or whatever you set it for. The cylinder you drew out of gets the majority since there...
  13. Replies
    3
    Views
    708

    Electronic expnsion valves

    Electronic expnsion valves
  14. Replies
    23
    Views
    2,219

    Dik, I see lots of clogged cap tubes W/pos...

    Dik, I see lots of clogged cap tubes W/pos oil(dont even get me started).You could replace cap tube and filter,change oil to alki or min, use alternate refrigerant. Med temp I like R-416. Or do the...
  15. Replies
    5
    Views
    935

    Ace I also hate working on taylor crap but since...

    Ace I also hate working on taylor crap but since nobody likes to it sure does make my job lucrative and secure . Thanks
  16. Replies
    5
    Views
    935

    First check temp of mix in both hoppers. If mix...

    First check temp of mix in both hoppers. If mix is warm you have refrigeration problem. If there is thick ice build-up remove probe on right side (after warming hopper) put probe ice-water, ohm leads...
  17. Replies
    4
    Views
    807

    Ice thanks for the reply. Your exactly right it...

    Ice thanks for the reply. Your exactly right it is short cycling and T-stat does not have time to react quick enough to rapid changing temps. Control is in evap, tried moving to sense air N.G. Do you...
  18. Replies
    4
    Views
    807

    Working on a med temp W/I cooler 6x6 the...

    Working on a med temp W/I cooler 6x6 the condensing unit is rated for 10,000 btu @35f box temp r-22 txv system.I know that it is way oversized but is there a way I can adjust txv to compensate untill...
  19. Replies
    71
    Views
    6,881

    Iam way out of my league here but has the unit...

    Iam way out of my league here but has the unit always used low temp ref?
  20. Thread: amp draw

    by taylortech
    Replies
    28
    Views
    3,291

    short cycling on a new freezor- it is full of...

    short cycling on a new freezor- it is full of product right?
  21. Thread: fr-12/r-416

    by taylortech
    Replies
    13
    Views
    2,647

    Use it all the time on med temp boxes. Unsure...

    Use it all the time on med temp boxes. Unsure about low temp.
  22. Replies
    2
    Views
    1,388

    John I know very little about stoelting but when...

    John I know very little about stoelting but when I see this problem I look first at run times they should be the same for both products(pull a swirl and see if this is true).Check product temp choc...
  23. Replies
    8
    Views
    965

    Yuma if you already have a good relationship with...

    Yuma if you already have a good relationship with the distributer in your area I would approach them first. If not then maybe a McDoanlds owner could get you in. The classes are ok but your probably...
  24. Replies
    4
    Views
    1,002

    Couple of things you might want to check. If you...

    Couple of things you might want to check. If you pull the charge out replace AXV. They stick open and feed during off cycle and wreck the product. Make sure beater is tight going into barrel if not...
  25. Replies
    3
    Views
    861

    Still unsure what model you have . Put the mix in...

    Still unsure what model you have . Put the mix in , set it warmer, see what comes out. The machine will freeze whatever mix you put in there the trick is to get it to dispense properly without...