    First choice Distech gfx for BACnet MSTP and...

    First choice Distech gfx for BACnet MSTP and Lonworks. EasyIO for Sedona and BACnet IP. Second choice Automated Logic and Siemens PPCL. Third KMC and Reliable Controls.
  2. Thread: Distech EC-GFX

    by debug69
    Replies
    12
    Views
    1,220

    I typically program with Distech GFX Lon or...

    I typically program with Distech GFX Lon or BACnet controllers on a station running on my laptop. If I want to test and debug live before heading off the job site then I connect a controller to my...
  3. Replies
    1
    Views
    650

    I have install several EasyIO30ps using the...

    I have install several EasyIO30ps using the sedona firmware which requires either AX or Sedona workbench. If you load the BACnet or Modbus firmware then the programing is configured thru a standard...
  4. Replies
    12
    Views
    2,053

    Controlchick, Both drivers will allow you to...

    Controlchick,
    Both drivers will allow you to command the Inet points (put Inet points in TEST or Manual). The big difference between Quicksilver's and Infocons (Lynxsprings version ) is that with ...
  5. Thread: Niagara Summit

    by debug69
    Replies
    12
    Views
    1,444

    This will be my first time. Looking forward to...

    This will be my first time. Looking forward to seeing the new Infocon / EasyIO products for AX.
  6. Replies
    12
    Views
    2,053

    Dcontrols, Lynxsprings Inet driver is...

    Dcontrols,

    Lynxsprings Inet driver is Infocon's Inet driver and should run fine on any manufactures Jace( We buy InfoCon drivers thru Lynxspring ). We have used it licensed with a Web Supervisor...
  7. Replies
    12
    Views
    2,053

    Rjgddc, We have have had great success with...

    Rjgddc,

    We have have had great success with both the Quicksilver Integrations Inet driver and Infocon Inet driver, both work well with a AX Jace.We also use the the Plexus OPC driver to Inet.One...
  8. Replies
    13
    Views
    1,041

    Zep913, With the Insight BACnet client option...

    Zep913,

    With the Insight BACnet client option you can add a BACnet BLN and use BOB Siemens (BACnet Object Browser ) to discover and add new BACnet devices and points. If your chiller is BACnet IP...
  9. Replies
    13
    Views
    1,041

    Zep913, You may be better off having your...

    Zep913,

    You may be better off having your customer purchases the BACnet Client option for Insight.Then add a BACnet MSTP to IP router between the the chiller and Insight. This would allow you and...
  10. Replies
    2
    Views
    477

    I'm pretty sure if you have the Sedona firmware...

    I'm pretty sure if you have the Sedona firmware loaded in your EasyIO30P controller you can only use the RS-485 port to connect to a Modbus serial network.It's my understanding that if you load the...
  11. I agree the Siemens Proprietary P1 Protocol is...

    I agree the Siemens Proprietary P1 Protocol is pretty rock solid(Worked with it for several years at a branch). But it is nice when you can have choices in the hardware you want to add to the network...
  12. Replies
    7
    Views
    1,005

    I have been installing the WLT900 on a site for...

    I have been installing the WLT900 on a site for the past year and have found them very reliable and will be probably adding another 100 plus over the next 4 years to this site. Each wireless Lon...
  13. Replies
    14
    Views
    1,261

    Distech Jaces are open to, so you should be in...

    Distech Jaces are open to, so you should be in good shape.

    Regards,
    Debug69
  14. Replies
    1
    Views
    986

    frontline, Are you linking discovered Lon proxy...

    frontline,
    Are you linking discovered Lon proxy points from the Distech controllers or did you use the Wire sheet on the Lon network to link the nvo's from one controller to the nvi's of...
  15. Replies
    9
    Views
    1,502

    BacNet, My original plan has been to always...

    BacNet,

    My original plan has been to always integrate to the Teletrol ivav controllers into the new Tridium AX front end. It's not about some of the VAV points aren't available, its about none of...
  16. Replies
    9
    Views
    1,502

    . Thanks for your input. This is what I...

    .

    Thanks for your input. This is what I suspected and have dealt with in the past.I find it unfortunate for the customer who wasn't left with a copy of the Teltrol "Edifice software" on site (I...
  17. Replies
    9
    Views
    1,502

    BacNet, Thanks for the reply. I have traced...

    BacNet,

    Thanks for the reply. I have traced out the MSTP network between the Teletrol ebuilding controller and the RTU which has the factory supplied BacNet card installed in it and I can...
  18. Replies
    9
    Views
    1,502

    BacNet, Thanks for the reply. I have traced...

    BacNet,

    Thanks for the reply. I have traced out the MSTP network between the Teletrol ebuilding controller and the RTU which has the factory supplied BacNet card installed in it and I can...
  19. Thread: MSTP IO

    by debug69
    Replies
    6
    Views
    727

    This product from HRW looks interesting. I have...

    This product from HRW looks interesting. I have not used it but would like to find a distributor here in the US to give it a try.The Siemens P1 protocol version looks like a nice option to.
    ...
  20. Replies
    9
    Views
    1,502

    Teletrol TLC-ivav MSTP

    I have a site utilizing several Teletrol TLC-ivav controllers on a MSTP bus connected to a Teletrol ebuilding controller. On this same MSTP network the RTU serving the Teletrol i-vavs has a...
  21. Replies
    48
    Views
    4,123

    Xarralu, I have been bench testing the LYX-30P...

    Xarralu,

    I have been bench testing the LYX-30P (This is Lynxsprings version of the EasyIO 30P-SF) and have been happy with it. It showed up in a plain cardboard box with no documentation, software...
  22. Replies
    15
    Views
    2,950

    Churchhvac, Looking at KMC's catalog under the...

    Churchhvac,

    Looking at KMC's catalog under the controller replacement cross- reference the official replacement for a 5502 is a KMD-5802. If the old controller contains PHONE / HANGUP statements,...
  23. Replies
    48
    Views
    4,123

    I have been using the AIC wireless LON...

    I have been using the AIC wireless LON transmitter (WLT900) for the last few months with great success. No problems with device...
  24. Replies
    5
    Views
    1,195

    basparky, I work for a controls service...

    basparky,

    I work for a controls service contractor that might be able to help you out with some of you issues.Shoot me a email if you wish to discuss.

    Regards,
    debug69
  25. Having trouble with a Fan in Lon network binding AX to Distech Gfx 300

    Iím trying to utilize the fan in nvi input #17 on a ECP 300 gfx controller to supply Avg , High and Low TerminalLoad from 7 Distech VVT controllers. I have linked the discovered Distech VVT...
Results 1 to 25 of 33
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event