    Thanks, I hve had one for about that long, I have...

    Thanks, I hve had one for about that long, I have never taken the orfice out to clean it. The flame is speading out on it.
  2. Replies
    2
    Views
    1,139

    Turbo torch tip cleaning

    :CU:Any one got any tips on cleaning turbo tuorch tips and reglator?
  3. Replies
    16
    Views
    931

    Well maintaiened and sized correctly.

    A system that can't satisfy the stat will do it SOMETIME. a local quick mart does that every time it around 95, only has a 2 ton, should have 5, anyway I was just thinking out loud , because it is...
  4. Replies
    16
    Views
    931

    When it is 95 outside some compressors will kick...

    When it is 95 outside some compressors will kick out on the thermal limit. Then after the compressor cools back down it kicks back on.
  5. Thread: micron gauge

    by crankbait
    Replies
    1
    Views
    433

    micron gauge

    I have to get a good one, which is best for the money?
  6. Replies
    19
    Views
    3,354

    Its a goodman heat pump 13 seer , 3yrs old still...

    Its a goodman heat pump 13 seer , 3yrs old still under parts warranty, don't know who installed it, they must have not used thermal block when they brazed it in, Carrier used to have some awsome...
  7. Replies
    19
    Views
    3,354

    Schrader not leaking,just under caps on top of...

    Schrader not leaking,just under caps on top of allen valves,what kind of leak lock, rector seal brand is what I use but I am still geting a bubble on the high side.
  8. Replies
    19
    Views
    3,354

    leaks under service valve caps.

    Anyone got any tips on stopping leaks under caps on ac condensing units , any special sealent to put on cap threads?:anyone:
  9. I Had to have a couple of customers' build soild...

    I Had to have a couple of customers' build soild fences around them to keep the wind from freezeing the gas line, the gas in this part of the country has a lot of water in it. I tell people who want...
  10. A big negative with any pack unit is that every...

    A big negative with any pack unit is that every thing is outside, which means you have to heat the exchanger, supply duct etc, outside in the cold before you begin to heat the inside of the...
  11. Replies
    2
    Views
    724

    Do you have only one hvac system for both up and...

    Do you have only one hvac system for both up and down ? If you do only have one this can be a confort control problem nightmare. Barring installing another system for the upstairs, there are many...
  12. Replies
    6
    Views
    402

    I did not say I did not know, bama, I said I was...

    I did not say I did not know, bama, I said I was looking for a simple way to explain it, which I found .Thanks baldloonie
  13. Replies
    13
    Views
    1,025

    I was not yelling sorry

    I did not have my bifocals on and caps locked so I could see what I was typing at age 50 I am getting old and blind lol
  14. Replies
    13
    Views
    1,025

    They are 3/4 and 3/8 just thought is was wierd?

    They are 3/4 and 3/8 just thought is was wierd?
  15. Replies
    6
    Views
    402

    W&R wires going to heat pump

    Why does a heat pump have r and w running to the hp condensor unit? I am havig trouble explaining it to my help.
  16. Replies
    13
    Views
    1,025

    NO IT IS A RESIDENTIAL 3 TON UNIT ONE...

    NO IT IS A RESIDENTIAL 3 TON UNIT ONE COMPRESOR,LEVEL RUNS. BOTH LINES A LIQUID AND SUCTION, THE UNIT WAS THERE WHEN THE CURRENT OWNER PURCHASED THE HOME. I REPAIRED A SMALL LEAK, JUST THOUGHT IT WAS...
  17. Replies
    13
    Views
    1,025

    TWO SUCTION AND LIQUID LINES??

    WENT ON A CALL , SOMEONE HAD PUT A TEE IN THE SUCTION AND LIQUID LINES AT THE CONDENSER AND RAN TWO LINES EACH TO THE EVAPORATOR AND TEE BACK INTO THE SINGLE LINES ????? WHY?
  18. Replies
    0
    Views
    381

    UV MICRO LEAK DETECTOR

    Is the ritche leak scannerII a good one? I have to buy one soon.
  19. Replies
    0
    Views
    245

    micro uv leak dector

    Is ritchie leak scanner II a good uv dector? I have to buy one soon.
  20. Replies
    0
    Views
    279

    UV MICRO LEAK DETECTOR

    WHICH IS THE BEST UV MICRO LEAK DETECTOR, IS THE RITCHIE LEAK SCANNER II A GOOD ONE? I HAVE TO BUY ONE REAL SOON.
  21. Replies
    10
    Views
    2,598

    that is so cool Mr Bll

    that is so cool Mr Bll
  22. Replies
    10
    Views
    2,598

    yea, it has enough room, it appears to be a...

    yea, it has enough room, it appears to be a novice installation. it has a 4 ton evaporator and a 2.5 ton condensing unit, I just hate to straiten out someone else's
    mess, It is diffucult to explain...
  23. Replies
    10
    Views
    2,598

    AC COIL INSTALLATION GAS FURNACE

    I Have a down flow gas split system furnace with the ac coil above the furnace installed in the return air side. I have always been taught that the coil goes on the supply side in gas furnaces?
  24. I sure hope you have a co alarm, I would call...

    I sure hope you have a co alarm, I would call some out very fast to check the heat exchanger.