  1. Replies
    14
    Views
    28,076

    Ditto, The only time you will really smell...

    Ditto,

    The only time you will really smell burning dust is when you fire it up for the first time for heating season. Even so, the smell usually goes away in less than an hour. A "bad gasket" is...
  2. Replies
    31
    Views
    3,761

    Yes,you are completely correct. I apologize for...

    Yes,you are completely correct. I apologize for my shortness in my prior post. 20A per 5kw, not 10 kw. And I did mean W1 and W2. Long day at work with some very ignorant customers. Not an excuse...
  3. Replies
    31
    Views
    3,761

    You can do whatever you want. Most heat strip...

    You can do whatever you want. Most heat strip packages come with one sequencer or contactor for each 10 kw of heat. A 15 kw package would have two sequencers and you can stage them if you would like....
  4. Replies
    31
    Views
    3,761

    A 10kw jeat strip usually draws between 19 and 22...

    A 10kw jeat strip usually draws between 19 and 22 amps. A 20 amp breaker for each 10kw of heat plus the 10 for the fan will cover it. If you worked on them you would know this. It is common knowledge.
  5. Replies
    31
    Views
    3,761

    You can stage 5 and 5 but you would need to add...

    You can stage 5 and 5 but you would need to add an extra heat sequencer or contactor (depending what brand of a/h you have) and have a 2 stage thermostat. Personally, I don't like staging anything...
  6. So from my understanding ( please, correct me if...

    So from my understanding ( please, correct me if I'm wrong) your biggest issues are the fact you don't feel they "purged/flushed" the lineset properly and they didn't use a vacuum gauge? First off, I...
  7. I have 3 sets of gauges in my truck, two R22/410...

    I have 3 sets of gauges in my truck, two R22/410 and one 22. I also use them interchangeably and have never had a single issue because of it. Just be sure to purge them after every use to make sure...
  8. Replies
    31
    Views
    3,761

    10kw would be borderline, hard to say w/o a load...

    10kw would be borderline, hard to say w/o a load calc. I wouldn't worry about having 3 stages, just do 10kw first and 5 on second. You will need 20A per 10 kw of heat plus your blower (figure 10A)....
  9. With all due respect, if you'd spent as much time...

    With all due respect, if you'd spent as much time researching install company's as you have posting the outcome of your actual install, you probably wouldn't be in this mess. I truly do feel for you...
  10. Replies
    46
    Views
    11,476

    Did one a few weeks back. Pretty straight...

    Did one a few weeks back. Pretty straight forward, not much different. Just read the manual and don't use an impact on the door screws.
  11. Replies
    5
    Views
    480

    16i only comes in full ton sizes so if it...

    16i only comes in full ton sizes so if it calculated to 3.5 tons you would go up to a 4ton. I live in SE Texas and my house is about 100 sq ft larger than yours and I'm going 4 ton on my 20i so I...
  12. Replies
    80
    Views
    5,653

    I think you may be expecting too much. No install...

    I think you may be expecting too much. No install company will be able to satisfy your demands completely. The load calc is designed for a specific cfm and any time you change fan speed the air flow...
  13. Replies
    26
    Views
    3,270

    You can trap the secondary but it is not...

    You can trap the secondary but it is not necessary. I've seen hundreds if not thousands of horizontal installs that didn't have the secondary trapped and I've never seen it cause the pan to overflow....
  14. Replies
    26
    Views
    3,270

    Except the problem wouldn't be solved. Your drain...

    Except the problem wouldn't be solved. Your drain theory is correct but the water in the pic is clearly condensation and not overflow. Just look how it beads up on the bottom of the drain pan where...
  15. Replies
    26
    Views
    3,270

    Sounds like your fan speed is set up too low. May...

    Sounds like your fan speed is set up too low. May want to have a tech raise the cfm if possible. With the fan on low speed all the time it is collecting too much moisture inside the cabinet. Raising...
  16. Replies
    40
    Views
    3,881

    This is what's going in my house in April. Wish I...

    This is what's going in my house in April. Wish I could do foam but the house is existing so not really an option w/o major renovation. Planning on blowing in about 24" of insulation after new...
  17. Replies
    5
    Views
    780

    I wouldn't spray anything on my coils. As long as...

    I wouldn't spray anything on my coils. As long as you keep your house clean, use good filters such as pleated cotton and change them when they are dirty (not just when your schedule says to) you...
  18. From what I gather you have an electric furnace...

    From what I gather you have an electric furnace correct? Does the aux come on every time there is a call for heat or only when you bump it up? Usually aux will come on in a heat call (correct me if...
  19. Replies
    26
    Views
    3,270

    In order for a trap to be functional it would...

    In order for a trap to be functional it would have to have
    water in it, correct? So the only way a secondary would have water in it was if it had water backing up in it or you poured water into it...
  20. Replies
    45
    Views
    3,526

    Then you might as well not use glue either. Just...

    Then you might as well not use glue either. Just because you can't keep from sloping the purple stuff all over doesn't warrant not using it. Yeah, it holds for now but a couple years down the road...
  21. Start with airflow. Links fail from time to time...

    Start with airflow. Links fail from time to time but it is rare, and two at the same time probably isn't coincidence. Check the run capacitor on the blower, if its ok run the Blower for a while (with...
  22. Heat pumps don't work well in colder weather (sub...

    Heat pumps don't work well in colder weather (sub 30's). Your aux heat should keep up somewhat though. Sounds like you may be short on heat strips or have one down. How many kw of aux heat do you...
  23. Other than being too close to the structure I...

    Other than being too close to the structure I don't see any reason to be too concerned. Unless its a heat pump ( which in your climate I'm hoping its not for your own sake) ice on the unit won't hurt...
  24. How exactly are you measuring the humidity? With...

    How exactly are you measuring the humidity? With out seeing pics its really hard to say if its improperly installed. Get a pro out there to check it out.
  25. I scrap anything a/c related, coils, copper,...

    I scrap anything a/c related, coils, copper, aluminum.
    I take in several loads a year whenever prices are high. Last load #1 copper was 2.30, #2 was 2.15, and reefer was 1.30 if I remember right....