Search:

Type: Posts; User: mlo1

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    18
    Views
    3,276

    I dug two post holes 3' apart and poured two sono...

    I dug two post holes 3' apart and poured two sono tubes. Each was fitted with rebar and a wet-set saddle bracket to hold a 4"x6". Two 3' sections of 4"x6" were then bolted to the saddle brackets. A...
  2. Replies
    5
    Views
    12,621

    You could cover it with a sheetstock or panels...

    You could cover it with a sheetstock or panels and fill with blown cellulose. Depending on the beam spacing you could build a "framed grid" for the panels to be supported with. Often the panels can...
  3. Replies
    1
    Views
    332

    A coil configuration...

    Current A-coil has the refrigerant lines routed through the cabinet on it's lower left side. Can a replacement A-coil be purchased with the lines formed to exit the cabinet on it's lower right side?...
  4. Replies
    27
    Views
    1,413

    Insulation is to be cellulose. I do not know the...

    Insulation is to be cellulose. I do not know the techs rationale for measuring in fpm, but I did specifically ask them to balance the duct system via the installed dampers before insulation was...
  5. Replies
    27
    Views
    1,413

    There is two places where I believe turning vanes...

    There is two places where I believe turning vanes could be added. One is directly below the AH where it empties into an 8x20 trunk in the crawl. One side of that trunk turns 180 up to the upper story...
  6. Replies
    27
    Views
    1,413

    The tech just stated SP was .63. I asked "is that...

    The tech just stated SP was .63. I asked "is that with the 5" media filter?", he stated it was. Did not actually use the term "total static". Would he typically be referencing it if it was not total...
  7. Replies
    27
    Views
    1,413

    Glad I checked as I found the blower setting...

    Glad I checked as I found the blower setting different than I thought I was told. The dip switch settings matched against the chart show 1625. The AH is a 4 ton. SP measures .63 with media filter.
  8. Replies
    27
    Views
    1,413

    Ooops, I do believe I set Tinner and everyone up....

    Ooops, I do believe I set Tinner and everyone up. I am sure it was feet per minute.

    Thanks beenthere
  9. Replies
    27
    Views
    1,413

    It has been and all appears well. 90% is what the...

    It has been and all appears well. 90% is what the techs were talking for optimum also.

    Thanks for the reinforcement!
  10. Replies
    27
    Views
    1,413

    Thank you tinner! Do you see a need to have...

    Thank you tinner!

    Do you see a need to have them re-test after a blower adjust for system critique?

    Does the methodology the techs used for balance indication seem accurate enough?

    My...
  11. Replies
    27
    Views
    1,413

    What does that mean...how could that be? Wrong...

    What does that mean...how could that be?

    Wrong setting...Larger AH than being told?

    or I am just being sloooow here and you mean to backer-down?
  12. Replies
    27
    Views
    1,413

    I may have the AH and HP sizes reversed. One is...

    I may have the AH and HP sizes reversed. One is rated as 3.5 tons and one is rated 4 tons. The tech specifically told me he changed the setting at the AH to 1850, I believe from 1400.

    The listed...
  13. Replies
    27
    Views
    1,413

    System flow balance...

    3.5 ton downdraft @ 1850 feeding 9 registers on the first story and 6 on second story. The second story maximum fpm values tested @ 672,667,654,645,665,644. The first story maximum fpm values tested...
  14. Replies
    19
    Views
    1,206

    That seems to be a no brainer...fallow a straight...

    That seems to be a no brainer...fallow a straight path from the AH to the HP. A casing installed through the slab will cost a little but quite easy.
  15. Replies
    7
    Views
    2,004

    haawill, I have seen nearly exact what you are...

    haawill, I have seen nearly exact what you are describing performed. I was a little stumped as to what exactly the units were until reading your post. It was a high-end remodel of a mid-century style...
  16. Replies
    58
    Views
    2,296

    Anne of Green Gables Mr. Blandings builds his...

    Anne of Green Gables
    Mr. Blandings builds his dream house
  17. Replies
    51
    Views
    2,612

    Mr. H.I. is a supposed non-trade proffesional...

    Mr. H.I. is a supposed non-trade proffesional (DIY) asking for advice to impersonate a trade proffesional (for a fee). Paying for the info on a ride along basis or joint trade basis is apparently not...
  18. Replies
    7
    Views
    591

    http://www.penray.com/managex/index.asp?x=313&y=31...

    http://www.penray.com/managex/index.asp?x=313&y=319&articlesource=319&navID=power
  19. Thread: spark plugs

    by mlo1
    Replies
    16
    Views
    865

    Autolite copper core cheapies are still the best...

    Autolite copper core cheapies are still the best value in a over the counter plug. AC's have been farmed out and de-specced for several years now. Beru from Germany makes a silver core plug that is...
  20. Thread: drum brakes

    by mlo1
    Replies
    37
    Views
    1,872

    silicone grease

    silicone grease
  21. Thread: drum brakes

    by mlo1
    Replies
    37
    Views
    1,872

    GM's return to drum rear brakes on selected...

    GM's return to drum rear brakes on selected trucks is based on several things. Most notably is the fact the low quality steel the rotors are made from does not hold up to the de-icer's. For hauling...
  22. Replies
    28
    Views
    1,373

    With todays low voc belended pump fuels the...

    With todays low voc belended pump fuels the distilation curves are completely wrong for throttle response and making power. Aside from purchasing private label sealed cans of properly blended fuels...
  23. You do not need a seperate checking account for a...

    You do not need a seperate checking account for a sole proprietorship. Most people working at banks today have absolutely no working knowledge of such details. I would pull the account and go to a...
  24. Replies
    9
    Views
    548

    Generally speaking what you have said is not...

    Generally speaking what you have said is not accurate. Octane levels of regulated fuel station pump fuels have no influence over combustion temperature.

    Our cars "fuel rate" and "octane levels"...
  25. Replies
    54
    Views
    2,756

    We will add your family to our prayers.

    We will add your family to our prayers.
Results 1 to 25 of 196
Page 1 of 8 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event