    The resistor is installed in the wiring harness...

    The resistor is installed in the wiring harness so you can use a power stealing thermostat.
  2. Replies
    7
    Views
    2,137

    Did you recieve the info?

    Did you recieve the info?
  3. Replies
    7
    Views
    2,137

    I need your email address.

    I need your email address.
  4. Replies
    7
    Views
    2,137

    I have info. What do you need?

    I have info. What do you need?
  5. Replies
    23
    Views
    1,041

    What's the over/under?

    What's the over/under?
  6. Replies
    9
    Views
    477

    I would get a second opinion. There is a reason...

    I would get a second opinion. There is a reason that there a burn marks on the furnace, not "that it's been like that and it will be ok as long as you don't run the heat at 80 for a long time"....
  7. Replies
    10
    Views
    1,216

    Poor craftsmanship!!!! Did the...

    Poor craftsmanship!!!! Did the contractor/auditor find any other problems?
  8. Replies
    22
    Views
    3,690

    Check your mail.:patriot:

    Check your mail.:patriot:
  9. Check your incoming water pressure. You may need...

    Check your incoming water pressure. You may need a pressure regulator before the humidifier. I've seen this problem in the past.
  10. Replies
    14
    Views
    1,624

    What system will you be using?

    What system will you be using?
  11. Replies
    14
    Views
    1,624

    What control do you have on the VAV boxes, are...

    What control do you have on the VAV boxes, are they trane UCM controllers?
  12. Replies
    13
    Views
    1,878

    The tracpipe certification was a joke. I think...

    The tracpipe certification was a joke. I think my seven year old could get his. Certified or not certified this install reeks of Jack Leg Heating and Cooling.
  13. Twenty minutes till beerthirty!!!!:couch:

    Twenty minutes till beerthirty!!!!:couch:
  14. Personally I would have heat pumps checked out...

    Personally I would have heat pumps checked out twice a year, once in the spring once in the fall. As far as a contract is concerned you might save some money by signing up for one, discounted labor...
  15. Replies
    4
    Views
    474

    One of the techs I work with had this done to...

    One of the techs I work with had this done to both knees over a year ago. He said he can't believe the difference. He does take it easier on his knees now ie: knee pads, not jumping down off the...
  16. With out looking at what you have we can only...

    With out looking at what you have we can only speculate, but I would suggest that the supply to the radiators should have been parallel instead of in series. The majority of the heat from the water...
  17. This seem to be problem with heat pumps in the...

    This seem to be problem with heat pumps in the southern states. Coil cleaning alone will not solve the problem. Contact a contractor and have them look into installing UV lights at the evap coil.
  18. Replies
    4
    Views
    1,350

    The joints should be glued together. This...

    The joints should be glued together. This furnace produces condensation as it operates, and drains out of the furnace. The drain is usually tied into the drain from the evap coil. The pipe does...
  19. Replies
    33
    Views
    2,811

    I can only imagine what the rest of the install...

    I can only imagine what the rest of the install looks like. You get what you pay for is all I can say.
  20. Replies
    22
    Views
    2,321

    I have found that this dirty sock problem rears...

    I have found that this dirty sock problem rears its head during the defrost cycle. Coil cleaning alone does not solve the problem. We generally install UV lights at the evap coil. This just treats...
  21. Replies
    3
    Views
    1,635

    We have worked with a couple of these hot yoga...

    We have worked with a couple of these hot yoga studios and found that the Honeywell T775 universal controller work great. It can be powered 24v and it allows you to set the temp to 105 or 110.
  22. This may have already been covered, but gooman...

    This may have already been covered, but gooman has been having problems with their rev. valves. There should be a service release concerning the problems.
  23. Replies
    20
    Views
    3,901

    What is that a moonshine still?

    What is that a moonshine still?
  24. I would personally say the Carrier system. That...

    I would personally say the Carrier system. That may be biased as we are a Carrier Factory Authorized Dealer. One thing about the Lennox is they do have reliable equipment, but try and get parts or...
  25. Replies
    15
    Views
    1,841

    Your right. I've seen them mounted just about...

    Your right. I've seen them mounted just about any position execpt upside down.
  26. Replies
    8
    Views
    422

    It is time to find a new HVAC company. Two...

    It is time to find a new HVAC company. Two compressors in less than a year?
  27. Replies
    19
    Views
    854

    A zone system may not be out of the question,...

    A zone system may not be out of the question, unless the duct is unaccessable. If you have access the zone system can be a easy retrofit. Honeywell should have a list of contractors that can advise...
  28. Replies
    19
    Views
    854

    A multi speed fan usually operates on only two...

    A multi speed fan usually operates on only two speeds, one for cooling and one for heating. A varible speed fan starts off at a slow speed, then over a period of time begins to ramp up. At then end...
  29. Replies
    3
    Views
    667

    Talk to the instructor at your school, he may...

    Talk to the instructor at your school, he may have a line on a good company. Also about the time you should finish the spring season will be starting and most companies do their hiring for the up...
  30. Replies
    19
    Views
    854

    Have you considered a zoned system or is that not...

    Have you considered a zoned system or is that not possible? Zoned systems do a great job redistributing the air around your house as the load changes. If the system is properly sized this may be...
  31. Replies
    13
    Views
    1,134

    You are right the humidity outside during the...

    You are right the humidity outside during the colder months is lower. It seems to me that your windows could be the suspect, you did say that they were single pane. You should see what the humidity...
  32. Replies
    3
    Views
    643

    Look into a hybrid or duel fuel setup. This uses...

    Look into a hybrid or duel fuel setup. This uses a combo heat pump and gas furnace. The heat pump does the heating down to a preset outdoor air temp, usually around 35 to 40 degrees. After that...
  33. Replies
    3
    Views
    732

    They seem legit enough from their web site. Try...

    They seem legit enough from their web site. Try a google search, you should find all the info you need.
Results 1 to 33 of 36
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event