  1. Replies
    30
    Views
    3,850

    hold the advanced button down (bottom right next...

    hold the advanced button down (bottom right next to basic) for approx. 10 seconds and the Evolution will go into service/setup mode and you check static in the Furnace status section.
  2. Replies
    26
    Views
    2,232

    could have had a heat load calculation done to...

    could have had a heat load calculation done to size the furnace (manual J) or HVAC Calc above. If that says you only need 40,000 Btu then there ya go.
  3. Replies
    1
    Views
    534

    Just wondered if anybody out there has ever seen...

    Just wondered if anybody out there has ever seen hoffman specialty D.C. operated hot water zone valves?
  4. Thread: air filter

    by jeff1234
    Replies
    12
    Views
    1,060

    I have gotten that replace filter message on...

    I have gotten that replace filter message on Bryant Evolution systems I have installed. The duct system is restrictive and it thinks the filter is dirty all because my boss the salesman sells the...
  5. Replies
    77
    Views
    10,167

    it's the temp difference between supply air and...

    it's the temp difference between supply air and return air at the furnace and should be listed on the furnace rating sticker. You should have two temp rise ratings one low fire and one high fire.
  6. Replies
    77
    Views
    10,167

    if it's all enclosed as in a counterflow on slab...

    if it's all enclosed as in a counterflow on slab or something like that and you can't get a temp reading near the furnace out of the direct path of the heat exchangers you can try the nearest supply...
  7. Replies
    16
    Views
    1,561

    Kinda like when Clark Griswold ended up getting...

    Kinda like when Clark Griswold ended up getting stuck with the family truckster.
  8. Thread: Evolution

    by jeff1234
    Replies
    0
    Views
    600

    I just wondered if anyone has any opinions on...

    I just wondered if anyone has any opinions on Bryant Evolution systems? Any problems yet?
  9. Replies
    16
    Views
    2,852

    I've heard the same thing, unplug the sensor.

    I've heard the same thing, unplug the sensor.
  10. Replies
    77
    Views
    10,167

    I'm not familiar with Trane equipment but with a...

    I'm not familiar with Trane equipment but with a Bryant 2 stage furnace you can use a 2 stage stat or you can use a 1 stage stat and the circuit board runs in what is called an adaptive mode. If I...
Results 1 to 10 of 18