Search:

Type: Posts; User: K_Neil

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    81
    Views
    7,241

    If he can't take it now what happens on a sunday...

    If he can't take it now what happens on a sunday afternoon when the icecream is melting in the walkin freezer of an ignorant ahole customer?
  2. Replies
    16
    Views
    673

    Are you Larry Moe or Curly?

    Are you Larry Moe or Curly?
  3. Way back in the apprentice days I worked on a...

    Way back in the apprentice days I worked on a walk in freezer that had died (R-12 days). Got it running but the moisture from the meltdown wouldn't stop dripping from the ceiling and the temp stayed...
  4. 308 shell is a lot shorter than 30 06....

    308 shell is a lot shorter than 30 06. Performance is same but the semiauto action doesn't have as far to go to get the next shot in.
  5. You might have to seal all outside seams then...

    You might have to seal all outside seams then wait till all the moisture that is in the insulation has time to get to the cold side of the panel and drain out. The moisture will always migrate to the...
  6. Replies
    19
    Views
    1,990

    Worrying about what you don't know is a waste of...

    Worrying about what you don't know is a waste of time. Use the time to learn about whatever you are working on. Just had a big renovation in a customer grocery. It changed from 1975 to 2007...
  7. Replies
    15
    Views
    1,312

    I've been self employed since I put in the...

    I've been self employed since I put in the apprenticeship hours and got my journeyman's ticket in 1985. The work was for a mom/pop company and I learned a lot about a lot of different things. Butcher...
  8. Replies
    28
    Views
    2,169

    The ori/ord head pressure set up uses the hot gas...

    The ori/ord head pressure set up uses the hot gas from the discharge line to heat the receiver with a flooded condenser to hold the pressure long enough for the system to produce the heat. I use the...
  9. Replies
    17
    Views
    1,006

    Technicians do the work supervisors do the...

    Technicians do the work supervisors do the talking. My uncle is in a similar trade and he would rather work the night shift on his job because there is a lot less white hats (supervisors had to use...
  10. Replies
    17
    Views
    1,006

    What kind of refrigerant? How old is the unit?...

    What kind of refrigerant? How old is the unit? Did you look up the specs on the Master Bilt website? 0 deg F is frozen food temp.
  11. "It" hasn't run into a cranky old veteran yet....

    "It" hasn't run into a cranky old veteran yet. Put together a pic of the dirtiest part of the trade with the caption "Glad YOU know more than me."
  12. Water supply might be an issue. What kind of...

    Water supply might be an issue. What kind of shape is the filter in (if there is one)? Cleaning is definately an issue and ice build up could of made the noise. Is there any sediment left in the...
  13. Replies
    34
    Views
    1,573

    Too much common sense involved with the design...

    Too much common sense involved with the design would lower sales. Will we ever see true build to last pride again?
  14. I get to work on old passenger rail car A/Cs that...

    I get to work on old passenger rail car A/Cs that have been converted from r12 belt drive to r22 hermetic. The units work great. The biggest problem is the conductors learned where the thermostat is....
  15. Replies
    34
    Views
    1,573

    The high suction and low amps steers me towards...

    The high suction and low amps steers me towards bad valves.
  16. Replies
    34
    Views
    1,573

    Had lots of calls for bottom drawer freezer...

    Had lots of calls for bottom drawer freezer fridges all models. It just seems to be a bad luck shows up easy design. You would think the freezer on the bottom makes more sense tho. Top of the list...
  17. Replies
    9
    Views
    1,009

    It will be a foot in the door. Got to watch out...

    It will be a foot in the door. Got to watch out for off season layoffs?
  18. Replies
    16
    Views
    1,192

    How do they get rid of the water produced in the...

    How do they get rid of the water produced in the dental systems?
  19. Replies
    0
    Views
    407

    Old compressor info where to find it?

    The compressor I'm wondering about is Aspera Frigo Lic. Tecumseh
    mod AET 28
    What temperature is it designed for and what hp is it?
  20. Replies
    30
    Views
    5,194

    Can the compressor pull into a vacuum with...

    Can the compressor pull into a vacuum with suction valve front seated? Try closing the liquid line valve to see what happens to the pressures this will imitate llsv operation. The compressor head...
  21. Replies
    13
    Views
    1,121

    Is filter drier outlet warm? How fast does...

    Is filter drier outlet warm? How fast does pressures balance on shut down? If the freezer is already close to retirement age you could size the cap tube by compressor capacity with refrigerant type...
  22. Thread: on call

    by K_Neil
    Replies
    134
    Views
    12,596

    Here's an example of a max stress job. Got the...

    Here's an example of a max stress job. Got the call at 8 am from Royal Canadian Legion the beer cooler was too warm. I'm in a small town everybody knows each other etc. Got there by 11 am and there...
  23. Thread: on call

    by K_Neil
    Replies
    134
    Views
    12,596

    Same situation here and same age level. My Dad...

    Same situation here and same age level. My Dad was a plumber and I grew up working with him before switching to refrigeration. He had some good sayings that are never forgotten. The one I think of...
  24. Replies
    44
    Views
    4,547

    The retro information here is great. One thing...

    The retro information here is great. One thing I'd like to throw into the pile is the change from R22 in medium temp units. I have a lot of coolers of various sizes that will have to be changed from...
  25. Replies
    2
    Views
    401

    The old motor had 2 speed starting which kept the...

    The old motor had 2 speed starting which kept the crankshaft together. What would be a safe rpm for the compressor to run?
  26. Replies
    2
    Views
    401

    Old belt drive info

    Where can I find some performance info on an old Frigidaire belt drive compressor?
    Only #s found on comp 636370
    cwc
    ?829? ...
  27. Thread: Service manual

    by K_Neil
    Replies
    35
    Views
    2,817

    Happy Easter to everyone down there too. The...

    Happy Easter to everyone down there too. The right people skills could cure callbacks. Do you agree?
  28. Thread: Service manual

    by K_Neil
    Replies
    35
    Views
    2,817

    Sounds like a good idea to me

    Sounds like a good idea to me
  29. Proper voltage?

    Proper voltage?
  30. Thread: Service manual

    by K_Neil
    Replies
    35
    Views
    2,817

    A later reply said it was a tecumseh in a 2 door...

    A later reply said it was a tecumseh in a 2 door reach in prep table. Why are you guys so set against checking amps? I try and get as much info as possible. Had a small cooler where the problem was...
  31. Thread: Service manual

    by K_Neil
    Replies
    35
    Views
    2,817

    The way I read the problem was a dirty unit with...

    The way I read the problem was a dirty unit with no label saying how much gas it holds and system was empty. What should the amperage be on a cold evacuated system that needs an unknown amount of...
  32. Thread: Service manual

    by K_Neil
    Replies
    35
    Views
    2,817

    Had an apartment landlord ask me once "Do you...

    Had an apartment landlord ask me once "Do you think you are too expensive" when he first called and asked about a fridge repair. Told him " it sure sounds like it" when he asked for a cheaper helper....
  33. Replies
    10
    Views
    2,640

    It's a bit different up here but the ice supply...

    It's a bit different up here but the ice supply for commercial fishing up here in northern manitoba works the same. The fishermen pick up tubs of ice and take them to the lakes where they fish. The...
  34. Thread: Service manual

    by K_Neil
    Replies
    35
    Views
    2,817

    Always go with name plate first of course. Read...

    Always go with name plate first of course. Read earlier entries first too.
  35. Replies
    16
    Views
    1,112

    Where is the beer being delivered from?

    Where is the beer being delivered from?
  36. Thread: Service manual

    by K_Neil
    Replies
    35
    Views
    2,817

    The old ones sometimes need some magic. Get it...

    The old ones sometimes need some magic. Get it cleaned up and watch pressures, amps, temps. Amps are a good indication if everything is clean charge to 1 amp lower than RLA and see how things go....
  37. Replies
    18
    Views
    2,067

    The pipe was rubbing against something if it...

    The pipe was rubbing against something if it could slide or something was rubbing against the pipe. Watch out for doors being propped up against it etc. Should be able to see same kind of markings...
  38. Replies
    8
    Views
    885

    Sounds like your customer gambled and lost. Make...

    Sounds like your customer gambled and lost. Make sure he knows there might be no easy fixes before you get in too deep. Buying a 1988 vehicle and expecting to drive to Alaska would be a good...
  39. Replies
    18
    Views
    2,230

    You said you were "pushed" away from cleaning the...

    You said you were "pushed" away from cleaning the condenser on one of the calls. Clean condenser is a must to even come close to a diagnosis. way over most of the time cleaning the condenser solves...
  40. Replies
    12
    Views
    1,061

    This is the one I've had the best results with....

    This is the one I've had the best results with. Make sure you get the coffin back on a defrost asap
  41. Thread: r22 conversions

    by K_Neil
    Replies
    98
    Views
    10,597

    Starting to sound like vehicle mpg ratings from...

    Starting to sound like vehicle mpg ratings from the manufacturer. Does anyone out there feel like a volunteer refrigerant tester? Will there ever be a permanent replacement? I don't think so.
  42. Replies
    20
    Views
    2,094

    Back in the apprentice days when things were slow...

    Back in the apprentice days when things were slow and there was no warranty involved the boss got me to cut a compressor open that had caused the same headaches. The stress relief was good. It was a...
  43. Replies
    24
    Views
    2,273

    Had a small walkin freezer that had froze up so...

    Had a small walkin freezer that had froze up so bad it took out the evap fan blades and motors. The biggest problem was the freezer was packed so full the door couldn't close. The shelves were empty...
  44. Replies
    24
    Views
    2,273

    It doesn't solve the problem but leaning on the...

    It doesn't solve the problem but leaning on the pen when you write up the bill will help a little next time around.
  45. Replies
    52
    Views
    4,295

    Abnormal moisture will always find a way to plug...

    Abnormal moisture will always find a way to plug things up
  46. Replies
    52
    Views
    4,295

    If drain pan doesn't clear fast enough you will...

    If drain pan doesn't clear fast enough you will see ice on the cold side of the case. Open cases (headaches) are the garbage collectors where the grape seeds,gum,etc. wind up. The case drain flushed...
  47. Replies
    2
    Views
    859

    Probes are ok there was 1 loose probe connection...

    Probes are ok there was 1 loose probe connection at the controller. Tightened things up and good so far. The cooler was just freighted 600 Kms. and probably got shook up a bit.
  48. Replies
    2
    Views
    859

    Dixell thermostat display accuracy

    I am working on a small display cooler that is freezing the salads. I am not familiar with the case manufacturer but the problem is that the Dixell mod#XR40C electronic thermostat will run fine with...
  49. Replies
    43
    Views
    6,301

    Had a walk-in freezer with a door switch that...

    Had a walk-in freezer with a door switch that shut only the fans off. Disconnected it after numerous freeze up calls. Another one is store workers sneaking in there for their breaks on a hot day. The...
  50. Thread: howe ice flaker

    by K_Neil
    Replies
    4
    Views
    895

    Isn't the bowl really thick cast alluminum?

    Isn't the bowl really thick cast alluminum?