Search:

Type: Posts; User: codeslinger

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    26
    Views
    3,042

    Thanks Dash!

    Thanks Dash!
  2. Replies
    26
    Views
    3,042

    Will do. With all zones open? With only one of...

    Will do. With all zones open? With only one of the four open? Does too low a pressure means there is not enough airflow? Thanks.
  3. Replies
    26
    Views
    3,042

    P.S. I'm going to consider the sealed and...

    P.S. I'm going to consider the sealed and dehumidified crawl space but have to say money is a consideration as well as the fact we are in a high radon area and I like the idea of crawl ventilation...
  4. Replies
    26
    Views
    3,042

    An Infinity 16 system, horizontal mount with...

    An Infinity 16 system, horizontal mount with electronic air cleaner [filter and electronic grid]. A couple days ago, the entire air handling unit was sweating heavily evenly all over and about the...
  5. Replies
    26
    Views
    3,042

    Advice from all noted and thanks and will update...

    Advice from all noted and thanks and will update later as to the resolution! Dave
  6. Replies
    26
    Views
    3,042

    Economy == more sounds counter intuitive but...

    Economy == more sounds counter intuitive but hoped that was the case. Thanks and I will certainly discuss this as well. Dave
  7. Replies
    26
    Views
    3,042

    Shouldn't think I'm the only one in the area with...

    Shouldn't think I'm the only one in the area with a unit, ductwork and zone dampers in the crawl. We are even cooler than many areas around here since at 2500' elevation. That's why I'm sort of...
  8. Replies
    26
    Views
    3,042

    Thanks, I'll discuss that with the maint guy when...

    Thanks, I'll discuss that with the maint guy when he shows up. I'm a bit confused on this though since "economy" sounds like reduced airflow and I've read more than once that increasing airflow would...
  9. Replies
    26
    Views
    3,042

    Thanks and this makes sense but I have to say I...

    Thanks and this makes sense but I have to say I was totally blindsided by this since none of the dealers had even mentioned this as a potential issue. Seems like it should have been an immediate red...
  10. Replies
    26
    Views
    3,042

    Yes, but since it is a zoned system, perhaps not...

    Yes, but since it is a zoned system, perhaps not really. That is one thing I want checked out is that when some zones close down, some or completely, that the blower and stages throttle accordingly.
  11. Replies
    26
    Views
    3,042

    It makes ME wanna puke that of all the HVAC...

    It makes ME wanna puke that of all the HVAC dealers I talked with, NONE OF THEM [six dealers gave me bids] mentioned anything about the unit being in the crawl space or any issues with sweating at...
  12. Replies
    26
    Views
    3,042

    No, the unit has a drain but is sweating so bad...

    No, the unit has a drain but is sweating so bad it is dripping into the pan!
  13. Replies
    26
    Views
    3,042

    New Carrier Heat Pump sweating profusely

    Obviously a dew point issue but how normal is this? A 6 month old, four zone Carrier 16 Infinity R410 4 ton system in a 2750' house in Asheville, NC. The unit itself and the beginnings of all the...
  14. OK thanks!

    OK thanks!
  15. Are you saying that the Honeywell HM506 will only...

    Are you saying that the Honeywell HM506 will only put 9 gallons of water maximum per day into the air even if run 24x7? Thanks, Dave
  16. Well my HVAC contractor says he pretty much only...

    Well my HVAC contractor says he pretty much only installs the Honeywell HM506-H9808 which is a lot better than most if no all other humidifiers, even on Carrier systems, so would appreciate any...
  17. As I've said I'm not opposed to Carrier but have...

    As I've said I'm not opposed to Carrier but have the other concerns and $ is only one of them and my main concern is introducing mold and bacteria into the ductwork. I know that historically...
  18. A quite reasonable consideration. We did just get...

    A quite reasonable consideration. We did just get it mostly for backup in the event of a power outage or equipment failure. Not sure how to best calculate this though without previous bills to...
  19. Opinions wanted for humidifer for Carrier

    We love our new 4 ton, 4 zone Carrier heat pump system but now that we have added a fireplace the humidity is way too low and we need to buy a standalone humidifier. 25% out of a suggested 45%...
  20. Actually my meter is digital so not as easy to...

    Actually my meter is digital so not as easy to tell. I have a 4 zone system with all Carrier parts so think I should stay with the Infinity stat and which as far as I know has no means to turn on...
  21. [QUOTE=AggieEngineer;2041850] Thanks. That...

    Thanks. That works though do wish they would add an indicator to the main display :(
  22. Thanks for the input. I had gotten no notices of...

    Thanks for the input. I had gotten no notices of replies like I was expecting. What I was hoping was that the thermostat would show me when the strips were on somehow. For all the sophistication in...
  23. How tell if Infinity heat strips are on?

    I have a new 4 ton, 4 zone Infinity 16 seer system. I see where I am told if heat strips are used in emergency mode which I presume is when the freon system is broke for some reason, but how do I...
  24. Indeed, I am seriously considering getting that...

    Indeed, I am seriously considering getting that one! Must one buy the Carrier filters or are there decent 3rd party filter for the media filter? I understand the media filter has some special...
  25. I have to confess to sometimes trying to get a...

    I have to confess to sometimes trying to get a 100 different answers to sort out what is best or what I want to do. So nice to have you folks make great suggestions that I can think about to sort out...
  26. Replies
    8
    Views
    912

    Thanks so much. Great to have this resource. Did...

    Thanks so much. Great to have this resource. Did not seem right to me but not my specialty even though am technical so thought best to ask. Dave
  27. Seems would also be a major issue with ducting...

    Seems would also be a major issue with ducting them in parallel rather than just putting one under the air handler. I would not have the room for that so guess I'm sol on that arrangement.
  28. Adrian, how do design the ductwork such that...

    Adrian, how do design the ductwork such that installing a high MERV filter uses twice [or whatever value] the filter area? All but one zone of my ductwork will be new. All new return ducts. 4 zones...
  29. Thanks but I don't think I want to go the UV...

    Thanks but I don't think I want to go the UV route due to ongoing cost or problems. Besides basic annual or biannual service, I just want to replace the media filter once per year. Don't have any...
  30. I don't equate reasonable and cheap. You get what...

    I don't equate reasonable and cheap. You get what you pay for so if not cheap that is fine as long as it is good value.

    That said, is there a good high MERV media filter, such as the Lennox HC16,...
  31. Replies
    8
    Views
    912

    Siad he did a manual J [not a D though I don't...

    Siad he did a manual J [not a D though I don't think] and will give me a copy. I did not ask him about this yet as I wanted to check here first. Thanks.
  32. Replies
    8
    Views
    912

    Well I little doubt that it was not as simplistic...

    Well I little doubt that it was not as simplistic as just adding up the sq" [which is why I asked] yet it seemed that 5x 6" flex supplies off an 8" round was shy of what might be needed esp. when 2x...
  33. Excellent, thanks. I had looked there but somehow...

    Excellent, thanks. I had looked there but somehow missed it.
  34. Replies
    8
    Views
    912

    Duct sizing math

    If an 6" duct is 28.27 sq" and one needs five of them, is it reasonable that the supply trunk has approx 141 sq" inches or does ductwork "math" not work like that? Not trying to become an HVAC expert...
  35. Any way to read threads from 1st post to last?

    I have not found one and find it cumbersome to go to a thread and then go tot he last page which has the first post, then go tot he bottom of the page and read upwards, then go to the previous page...
  36. Media filter suggestions for Carrier Infinity

    I am installing a Carrier Infinity 4 ton zoned system and mostly new ductwork in an older home and would appreciate some media filter suggestions. I do not want anything mechanical or ozone...
  37. Replies
    11
    Views
    6,712

    Thanks to all!

    Thanks to all!
  38. Replies
    11
    Views
    6,712

    Is this a single product? A mastic type tape? Or...

    Is this a single product? A mastic type tape? Or do you put down the mesh tape, then mastic over it? Or vice versa? Thanks, Dave
  39. Replies
    11
    Views
    6,712

    So what is best and what is reasonable to request...

    So what is best and what is reasonable to request of the installer? What is scrim? THanks
  40. Replies
    11
    Views
    6,712

    I'm guessing the foil tape goes down first, then...

    I'm guessing the foil tape goes down first, then the mastic?

    What do you do for the wrap?

    All my ductwork is in an unconditioned shop and crawlspace - none in any attic area.

    THanks!
  41. Replies
    11
    Views
    6,712

    By "duct" tape are you talking about the all...

    By "duct" tape are you talking about the all purpose gray stuff our government suggested we keep on hand for defense against chemical warfare attacks :D or the UL shiny tape? I certainly would not...
  42. Replies
    11
    Views
    6,712

    Mastic vs. UL tape vs. both

    I am getting estimates on replacing my HVAC system including new ductwork where possible. I have requested no duct board and want all metal ducts for the main trunks and flex to the supplies. My...
  43. Replies
    70
    Views
    4,125

    I suspect he meant the brand...

    I suspect he meant the brand...
  44. Replies
    70
    Views
    4,125

    Absolutely, assuming I go with the dealer that...

    Absolutely, assuming I go with the dealer that wants to zone.
  45. Replies
    70
    Views
    4,125

    I talked to the NC district technical rep last...

    I talked to the NC district technical rep last Friday and only last month the Trane zoning has been upgraded [software] and is now approved for zoning. This is something new and there is a service...
  46. Excellent, Thanks!

    Excellent, Thanks!
  47. I know TXV is thermal expansion valve, but is...

    I know TXV is thermal expansion valve, but is that not standard on the upper end systems? Is it something optional or just depends on the individual air handler? Thanks.
  48. Is 2/4TEE air handler with builtin Clean Effects Better?

    For a Trane XL15i or XL16i system, is the 2/4TEE air handler with the builtin Clean Effects better or worse than getting the separate Clean Effects unit?

    Pros and Cons?

    Also, is it normally...
  49. Replies
    70
    Views
    4,125

    Sorry, the Trane literature calls the XL16i a "2...

    Sorry, the Trane literature calls the XL16i a "2 stage" unit! Not my terminology.
  50. Replies
    70
    Views
    4,125

    My more expensive contractor told me that they...

    My more expensive contractor told me that they HAVE to price the supplies at $XXX each. Seemed odd to me other than a ball park figure that should be modified per the actual situation. Thanks for the...