Search:

Type: Posts; User: Maximum19

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    2
    Views
    1,118

    Can I change my screen name?

    I started with HVAC-Talk as a service technician, but I have moved up into a professional service trainer. and I would like to be able to display my actual name and credentials. is it possible to...
  2. Replies
    52
    Views
    9,027

    If you have found the leak then yes it is good to...

    If you have found the leak then yes it is good to fix it. But if it is a slow leak that is just a few lbs a year. Then is it not the customers choice as to how much they want to put in it.

    No...
  3. Replies
    52
    Views
    9,027

    Good point Gerber! Also my options with sealer...

    Good point Gerber!

    Also my options with sealer also include options with kick starts added which will help keep compressors that are one there way out from failing right away.
  4. Replies
    52
    Views
    9,027

    The old type had some issues but since they added...

    The old type had some issues but since they added the dry R to it i have not had any compressor failures.

    And you can not say that one can is an accurate test. Once you put in a hiegher volume you...
  5. Replies
    52
    Views
    9,027

    No commission just chosen by clients.

    No commission just chosen by clients.
  6. Replies
    52
    Views
    9,027

    Cliplight. Total 2 works great i put 200 cans in...

    Cliplight. Total 2 works great i put 200 cans in last year and on track for 300-400 this year. We put them in as a preventative in r22 units also to prevent unessasary coolant loss. So far only had 3...
  7. Replies
    39
    Views
    2,294

    My boss used to get upset all of the time and...

    My boss used to get upset all of the time and went through alot of employees because of it. Then i started to pay attention to what set him off..... POOR RESULTS!

    He had spent so much money...
  8. Replies
    7
    Views
    1,026

    I dont use that control but we used to use a...

    I dont use that control but we used to use a totaline stat that said you neded a resistor if you did not have a common. But the only way i could make it work was with 2 resistors.
  9. Replies
    36
    Views
    3,453

    I heard that the flame sensor had little holes in...

    I heard that the flame sensor had little holes in it that would be damaged by sand paper.
  10. Replies
    23
    Views
    2,178

    Ive used 4-5 cans of super seal total 2 every...

    Ive used 4-5 cans of super seal total 2 every week this summer and no more leaks yet. I do recommend a hard start with it though. Just in case!
  11. Replies
    36
    Views
    3,453

    I use it all the time because it is smooth enough...

    I use it all the time because it is smooth enough not to harm the flame sensors but has a slight sanding quality to remove debris
  12. Replies
    177
    Views
    8,282

    Ok. I talked to my distributer ( NOLAND SUPPLY)...

    Ok. I talked to my distributer ( NOLAND SUPPLY) and they said that the extended 5 yr labor warranty is for e coils that where made from 1-1-10 to 1-1-12 but that where installed AFTER 07-01-11 and...
  13. Replies
    177
    Views
    8,282

    Yes they gave me a flyer. Ill look it up and post...

    Yes they gave me a flyer. Ill look it up and post details.
  14. Thread: Double unit.

    by Maximum19
    Replies
    18
    Views
    785

    Sounds just like a multi zone mini split. But...

    Sounds just like a multi zone mini split. But with duct work.
  15. Replies
    56
    Views
    4,692

    We have all had the systems in the early days...

    We have all had the systems in the early days when sealers messed up a system. But the important thing is that at least cliplight is improving there product to fix the issues. And since i dont have...
  16. Replies
    56
    Views
    4,692

    Its for those systems that need charged on an...

    Its for those systems that need charged on an annual or simi annual basis and when a full repair is not avaliable or not cost effective to the client.
  17. Replies
    18
    Views
    1,098

    Alright SuperTech, I re-posted the original...

    Alright SuperTech,
    I re-posted the original Question. but in a nut shell he was asking wether he should start pushing his clients to replace insted of repair..

    My answere is always absolutely NO...
  18. Replies
    18
    Views
    1,098

    Lol! No. talking about sales not your name....

    Lol! No. talking about sales not your name. Gross income.
  19. Replies
    18
    Views
    1,098

    Gross you should not, but net you CAN.. In...

    Gross you should not, but net you CAN..
    In todays market you can be a million dollar tech with out replacing equipment and without selling the home owner a nick nack device they don't need. And you...
  20. Replies
    18
    Views
    1,098

    Flip, It is a shame when a company will put...

    Flip,
    It is a shame when a company will put pressure on Techs to sell when all they really want to do is fix things. And truth be told the cust. Just wants you to fix things..
    In my company we use...
  21. Replies
    177
    Views
    8,282

    We only put in about 3-4 nordynes a month, and...

    We only put in about 3-4 nordynes a month, and have not had a leak yet..

    However i did get a anouncement from nordyne last week that they are tacking on a extended 5 yr. Evap coil warranty where...
  22. The clean effects has 210 sq ft of filter media?

    The clean effects has 210 sq ft of filter media?
  23. They do not go inline with a .00 static drop. And...

    They do not go inline with a .00 static drop. And guaranty 10xs cleaner air in one hour.
  24. Check it out there is nothing that comes close..

    Check it out there is nothing that comes close..
  25. Nope, Not selling anything i was in...

    [/QUOTE]

    Nope,
    Not selling anything i was in referance to the fact hat a clean effects or similar filtratin system will not solve these issues. Especilly without fixing the environment.
    ...
  26. Replies
    112
    Views
    11,874

    Since That warranty really makes that metal last...

    Since That warranty really makes that metal last longer right.

    Better make sure it is combusting right with low o2 or any heat exchanger will rust through.
  27. Replies
    56
    Views
    4,692

    Yes the oil based stop leaks make a really big...

    Yes the oil based stop leaks make a really big mess!
    That is still why cliplights total 2 is so much better, because if you do the steps to protect the system like moisture away and a hard start it...
  28. I hope you have not done that yet! Did you...

    I hope you have not done that yet!

    Did you know that according to 3rd party research 95% of all resperatory illness is directly caused by the air you breath in your home!!

    Also spray foam...
  29. Replies
    112
    Views
    11,874

    Lol... You may think that, but there are several...

    Lol... You may think that, but there are several companies in major class action law suites because of that mindset.
  30. Replies
    112
    Views
    11,874

    These are good posts. Now you should also...

    These are good posts. Now you should also possibly consult with Jim Davis at NCI. He is the leading furnace expert in the industry.
    Also if you use a combustion analyzer you will find that with a...
  31. Nice! I like the post on heating the exchanger...

    Nice! I like the post on heating the exchanger first. Thats good idea!
  32. Replies
    56
    Views
    4,692

    Yes it has came along way if you use the right...

    Yes it has came along way if you use the right stuff and the right way.
    Check out my earlier post for more info.
  33. I use visable deffects products. There dye works...

    I use visable deffects products. There dye works good and even though they don't want you to dilute it, it is very dilutable and works great to find drain leaks also.
  34. Replies
    29
    Views
    1,740

    We have put in some of the 95% mobil home...

    We have put in some of the 95% mobil home furnaces. They are high static, but they never fit the space. Make sure you charge enough to remove and rebuild a wall or two if you want it to work. They...
  35. Replies
    56
    Views
    4,692

    Yes i used to have that problem also. But now...

    Yes i used to have that problem also. But now with the New Flat Rate when cust do the cheaper repair( which for me is less then 10% off the time) and they have a problem a few weeks/months later...
  36. Replies
    56
    Views
    4,692

    Thanks Heat..

    Thanks Heat..
  37. Replies
    56
    Views
    4,692

    Yes we all want to be the best. But what happens...

    Yes we all want to be the best. But what happens if the cust. Cannot afford your services? But they can afford a patch? After you have told them what the right way is to fix it. Would you really want...
  38. Replies
    56
    Views
    4,692

    Sorry

    Sorry
  39. Replies
    56
    Views
    4,692

    Perhaps but my average "freon" repair call is...

    Perhaps but my average "freon" repair call is $850 so real home owners do not say "buh-bye"
    Home owners want the best repair that they can afford. And they choose higher ones when they can see the...
  40. Replies
    56
    Views
    4,692

    Lol.. Yes that is true. It is just my...

    Lol..

    Yes that is true. It is just my experiance that the techniques i use seem to work very well for me. And when i do a full system flush with acid away it seems to solve the issue. But yes line...
  41. Replies
    56
    Views
    4,692

    And no "gas it up" is just a figure os speech.

    And no "gas it up" is just a figure os speech.
  42. Replies
    56
    Views
    4,692

    I do see your arguement. But i have talked to the...

    I do see your arguement. But i have talked to the creater of the cliplight products and have asked similar questions. There answeres are sound and they do not seem to want to miss guide. Only to help...
  43. Replies
    56
    Views
    4,692

    Also. The total 2 product has pretty much fixed...

    Also. The total 2 product has pretty much fixed the moisture issue. The chemical additive can remove 60 drops of water. And if i suspect acid or moisture i can choose to pull an evac and flush the...
  44. Replies
    56
    Views
    4,692

    Lol.. Well i use The New Flat Rate in my...

    Lol.. Well i use The New Flat Rate in my company, so the cust. Gets the option of wether or not they want to find and fix the leak, put in an internal sealer, or just gas it up.. I have learned to...
  45. Replies
    56
    Views
    4,692

    If you are having issues with a leak you can't...

    If you are having issues with a leak you can't find then check into " clip lights" total 2 super seal. It is an internal leak sealer that works for both commercial and residential equipment with its...
  46. Thread: goodman...?

    by Maximum19
    Replies
    115
    Views
    8,201

    They are fine exept when tax credit units came...

    They are fine exept when tax credit units came out the had bad RV. That killed tons of compressors right away..
  47. Replies
    9
    Views
    597

    T.E testing only sees temp. Difference not...

    T.E testing only sees temp. Difference not infiltration..
    This works good along with the BD test but cannot take its place.
    Just because there is no insulation in a wall does not meen the wall is...
  48. Replies
    6
    Views
    452

    That is completely irrelevant. The floor or...

    That is completely irrelevant. The floor or ceiling is a rule of thumb.
    The amount of BTU's is all that matters. If you have the correct air flow to the room and have addressed issues with the homes...
  49. Replies
    51
    Views
    37,168

    Yes according to what efficiency the system is....

    Yes according to what efficiency the system is. You will need the super heat and sub cooling from the manufacture. Sub cooling- the degrees f. That the liquid line is compaired to the liquid...
  50. Replies
    17
    Views
    2,640

    We install ERV energy recovery ventilators for...

    We install ERV energy recovery ventilators for this type of issue. That will keep from bringing in cold air. And you can even run it through a dehumidification system in the summer if needed.
Results 1 to 50 of 65
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event