11-24-2008, 06:56 PM
Thread: Carrier 58PAV short cycle
by golan37- Replies
- 12
- Views
- 3,565
That shorter limit could be the cause of your...
That shorter limit could be the cause of your furnace catching fire at a later date!
Golan -
10-24-2008, 03:27 PM
Thread: Regarding: HX's
by golan37- Replies
- 3
- Views
- 272
I have seen nothing that would indicate that...
I have seen nothing that would indicate that either style of HX would outperforn the other for heat transfer. Tubular heat exchanger will often times allow for a smaller cabinet size though.
... -
10-24-2008, 03:13 PM
Thread: CONVERT or REPLACE an EAC to media ...?
by golan37- Replies
- 4
- Views
- 428
Any good HVAC technician should be able to seel...
Any good HVAC technician should be able to seel those gaps up for you with sheetmetal in order for a standard size filter to fit
Golan -
02-27-2008, 07:05 PM
Thread: Rigid See Snake at the Orange Monster
by golan37- Replies
- 40
- Views
- 3,277
If I try to use mine near anything shiny all I...
If I try to use mine near anything shiny all I get in the center of the monitor is glare! There is light, just a wavelength that the human eye doesn't see and is subject to all the problems with...
-
02-27-2008, 06:21 PM
Thread: Rigid See Snake at the Orange Monster
by golan37- Replies
- 40
- Views
- 3,277
You're having better luck with your "inspector"...
You're having better luck with your "inspector" cameras than I am. Fixed focus unit can't see anything up close, manual focus unit, nothing but glare upclose. Have to check any questionable areas...
-
02-27-2008, 05:47 PM
Thread: help- i need a good meter
by golan37- Replies
- 45
- Views
- 2,904
I'll add my penny's worth. Never trust to just...
I'll add my penny's worth. Never trust to just one meter. Stuff happens in the field! A good quality clamp meter and a good quality multimeter are minimal. One of these has to be capable of...
-
12-09-2007, 03:21 PM
Thread: Infinity System slow to heat house
by golan37- Replies
- 23
- Views
- 2,230
In your system the infinity control determines...
In your system the infinity control determines the required airflow and allows very little adjustment. The heatpump alone will be very slow to recover from setbacks. To alleviate this I would raise...
-
07-01-2006, 02:02 PM
Thread: New Coil Gun
by golan37- Replies
- 9
- Views
- 1,246
Been using one for about a year, they will go...
Been using one for about a year, they will go through some chemical though. Take the foamers off and toss them, the artifically generated foam doesn't penetrate well but the chemical/water steam goes...
-
Zoning is better than nothing! 2 systems is the...
Zoning is better than nothing! 2 systems is the better route!
-
02-10-2006, 01:49 AM
Thread: hurricane salvages
by golan37- Replies
- 12
- Views
- 810
As GAMA says on their website, if it's gotten...
As GAMA says on their website, if it's gotten wet, replace it!
-
02-10-2006, 01:37 AM
Thread: hurricane salvages
by golan37- Replies
- 12
- Views
- 810
As GAMA says on their website, if it's gotten...
As GAMA says on their website, if it's gotten wet, replace it!
-
01-02-2006, 01:24 PM
Thread: Help!!! Ist this Trane System 14+ SEER???
by golan37- Replies
- 10
- Views
- 3,062
I have a problem with using the ADP coil with a...
I have a problem with using the ADP coil with a Trane or AS. As a rule ADP's coils don't have as much capacity as Trane/AS condensers and significantly shorten then lifespan of their compressors. I...
-
01-02-2006, 01:18 PM
- Replies
- 7
- Views
- 779
My thoughts exactly Beenthere. Possible that...
My thoughts exactly Beenthere.
Possible that the termidistat is configured or wired incorrectly. Maybe a couple of wires that got shoted together somehow.
Golan -
01-01-2006, 01:21 PM
Thread: gas furnace problem, need help!
by golan37- Replies
- 6
- Views
- 970
Don't worry it'll quit again! Do yourself a favor...
Don't worry it'll quit again! Do yourself a favor and call someone to come out and give it a proper cleaning and check the system over completely.
golan -
01-01-2006, 01:03 PM
Thread: Carrier Infinity Frosting
by golan37- Replies
- 7
- Views
- 861
As long as it is just frost don't worry about it....
As long as it is just frost don't worry about it. If your old Lennox HP didn't frost in the same manor it was probably overcharged. Since it was forming frost at 55 degrees it is probably slightly...
-
01-01-2006, 12:53 PM
Thread: Replacement question
by golan37- Replies
- 16
- Views
- 1,496
The physical size of 13 SEER equipment will be...
The physical size of 13 SEER equipment will be decreasing very soon due to some new coil and motor technology. some manufacturers are preparing to rollout some 13 SEER equipment that is physically...
-
01-01-2006, 12:45 PM
Thread: Heating problem with Goodman CPLE24
by golan37- Replies
- 9
- Views
- 958
1.) something has happened that the heat pump is...
1.) something has happened that the heat pump is no longer providing heat.
2.) If the heat pump is not heating then set the stat to emergency until it can be looked at by a qualified service... -
12-29-2005, 07:41 PM
Thread: How effective are UV light systems?
by golan37- Replies
- 10
- Views
- 1,442
The U/V light will actually break down "most"...
The U/V light will actually break down "most" organic substances if they are exposed long enough. It will also destroy some of the cheaper made evaporator drain pans in the same manor.
Golan -
12-28-2005, 10:47 PM
Thread: How effective are UV light systems?
by golan37- Replies
- 10
- Views
- 1,442
If installed where they can shine on the...
If installed where they can shine on the evaporator coil they are great at keeping it clean but do little else, unless the design incorporates some method of slowing the airflow, and concentrating...
-
12-27-2005, 08:27 PM
Thread: To change or not to change AC Lines
by golan37- Replies
- 14
- Views
- 1,059
Agree totally with Toolpusher but I would always...
Agree totally with Toolpusher but I would always change out my own lineset as cheap insurance against contaminants getting in the new system from the old.
golan -
12-27-2005, 08:16 PM
- Replies
- 7
- Views
- 1,273
Having played this game for a number of years....
Having played this game for a number of years. You most likely will not notice the difference between the 2 in utility savings. There are many variables involved in the installation of a furnace that...
-
12-26-2005, 07:47 PM
Thread: silicon nitride ignitors
by golan37- Replies
- 43
- Views
- 3,004
I think I've replaced 2 of them since Trane...
I think I've replaced 2 of them since Trane started started using silicon nitride
-
12-26-2005, 06:29 PM
Thread: Moderation/Censorship
by golan37- Replies
- 54
- Views
- 2,562
Oh how wrong you are sir. Having participated in...
Oh how wrong you are sir. Having participated in online forums since the days of the old BBS systems before there was widespread internet access, this is an extension of the sysops/moderators home....
-
12-14-2005, 07:28 PM
Thread: Noise Level With High Efficiency Furnace
by golan37- Replies
- 4
- Views
- 1,147
The 80% furnaces are definitely noisier inside...
The 80% furnaces are definitely noisier inside the home due to their open combution chambers and in most cases the cheaper bearings used in their draft inducer motors.
-
12-14-2005, 07:00 PM
Thread: HP DX coil in return plenum
by golan37- Replies
- 8
- Views
- 1,332
Placeing the coil on the return side is correct....
Placeing the coil on the return side is correct. If on the supply side the heat pump might not like haveing 100 plus degree air blowing into its indoor coil. The furnace should be running while the...