Search:

Type: Posts; User: neonhomer

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    19
    Views
    2,406

    Not to bump a old thread, but could someone grace...

    Not to bump a old thread, but could someone grace me with a copy? Funny is that the Stryker graphics want the the file, but didn't come with the Stryker installer.
  2. With nviTodEvent, there is three points......

    With nviTodEvent, there is three points... currentstate, nextstate, and timetonextstate....

    I have the enum schedule linked to the nviTodEvent_currentState point, and the box seems to be...
  3. Honewell TR23 LED Blinking when VAV Overridden

    Controller is an Excel 10 W7751H, and the wall module is a TR23 w/ the Override button and LED. Front end is Niagara AX.

    When we send the boxes to unoccupied mode (by using the nviOccCmd), the LED...
  4. Replies
    20
    Views
    2,667

    Not all Honeywell Jaces will be tridium/niagara ...

    Not all Honeywell Jaces will be tridium/niagara

    But to answer the OP's original question, you can serial shell into the JACE and change the default platform username/password.
  5. I see NLUtil... from Newron systems... but it...

    I see NLUtil... from Newron systems... but it requires a login to get it... and there is no option for US....

    Anyone know anywhere else I can download it?

    Also.. found out why we had the...
  6. Tool to reset LON subnet/node/domain info

    We have a handful of LON VAV controllers that, due to a crappy network, failed commissioning through Niagara AX. We are looking for a program that we can run that will let us reset the LON...
  7. Try uninstalling and reinstalling the program....

    Try uninstalling and reinstalling the program. It's possible your license file is corrupted.

    If that doesn't work, then you might need to call in...
  8. Replies
    33
    Views
    4,211

    I've seen the big air handlers do that. Saw one...

    I've seen the big air handlers do that. Saw one in Miami in a brand new Trane M-Series... The wheel survived about a hour until it just imploded.

    Trane sent a completely new blower assembly out...
  9. Replies
    11
    Views
    1,727

    Holy underwear Batman! How many animals did they...

    Holy underwear Batman! How many animals did they have there?
  10. Replies
    0
    Views
    470

    Honeywell Microcell Controllers for VAV

    We have a bunch of old Microcell VAV controllers we pulled from a job. Looking to get rid of these things....
  11. Replies
    6
    Views
    581

    If you're tired of being spammed with the EPA...

    If you're tired of being spammed with the EPA message...

    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/16972
  12. Replies
    3
    Views
    455

    I personally haven't tried it. I'm on Windows 7...

    I personally haven't tried it. I'm on Windows 7 with 5.8.6 without issues.

    I would imagine if you use a 32-bit version of Windows 7, and the latest version of 4.0 (that you are allowed to use), it...
  13. Replies
    24
    Views
    4,595

    Must be nice to have a van... As a controls guy,...

    Must be nice to have a van... As a controls guy, I am driving a little Nissan Versa hatchback... What's worse is that the paint is fading, and it's white to boot! I try to keep it clean, but the...
  14. Replies
    27
    Views
    6,267

    I don't do refrigeration professionally (I'm a...

    I don't do refrigeration professionally (I'm a controls guy), but even I can unbolt a contactor from a unit to make the wiring connection if it is a bit too tight...

    On a side note, I replaced a...
  15. Replies
    3
    Views
    455

    Without a prompt for what? If you don't...

    Without a prompt for what? If you don't register/license WPT, it will nag you every time you start it. No way around it.

    Best thing to do is either upgrade to WPT (The latest being 5.8.6), or keep...
  16. Replies
    4
    Views
    1,137

    Swapped sub-bases... Temp still jumps around. ...

    Swapped sub-bases... Temp still jumps around.

    Only thing I can think of now is that maybe the wire is bad, or it is picking up noise,.,..,.,
  17. Replies
    4
    Views
    1,137

    Honeywell T7350 Temperature jumps around

    If you're wondering, it's the same job...

    A Honeywell T7350 tstat with the remote TR21-H Temp/Humidity sensor... The original complaint was the temperature was jumping around by 3-5 degrees, and...
  18. Replies
    5
    Views
    1,440

    If you want to get rid of that stat... You can...

    If you want to get rid of that stat... You can send it my way. I am looking for one to hang on to for a spare....
  19. Replies
    34
    Views
    5,669

    Would this module be found in the SoftJACE...

    Would this module be found in the SoftJACE download from NiagaraCentral? I am using TAC's version of AX, and a station I am working on is screaming about needing the VykonPro module....
  20. Replies
    0
    Views
    547

    WTB: ENC-420 or 520

    I am looking for a used ENC 520 or 420 to play around with. Maybe you have one that has a bad port, or something like that. Maybe one that needs recapped, or needs a new xfmr or the like.

    I am...
  21. Thread: i'm 98%

    by neonhomer
    Replies
    157
    Views
    29,739

    2% - Blue strippers (wire, people)

    2% - Blue strippers (wire, people)
  22. Replies
    28
    Views
    3,597

    When I had my interview for my controls...

    When I had my interview for my controls technician position, I wore a polo shirt, and non-faded pair of cargo pants, and a non-marked up pair of "duty boots" (black police boots, similar to army...
  23. Replies
    5
    Views
    1,440

    For anyone who was following... I ended up having...

    For anyone who was following... I ended up having to re-commission the stats. With just one, I pulled in all my points, configured them, and put in my setpoints. I then copied them to the other...
  24. Replies
    5
    Views
    1,440

    Hmmm... I am not using the standby cool/heat...

    Hmmm... I am not using the standby cool/heat setpoints...
  25. Replies
    5
    Views
    1,440

    Honeywell T7350 Lon stats and Niagara AX

    Grumble... Trying to set the Occupied/Unoccupied Heat/Cool setpoints from inside AX on these stats. When you try to do it through the nciSetpoint_occupiedCool (or the other four), the stat does not...
  26. Replies
    7
    Views
    1,297

    I was able to get out on a job and hook up. I can...

    I was able to get out on a job and hook up. I can communicate with a controller, but I still get the 1068 error.

    From what I have been reading, I guess I need the 8.08b update.
    ...
  27. Replies
    7
    Views
    1,297

    Okay. I figured out what was hogging my Com1...

    Okay. I figured out what was hogging my Com1 port. I have the USB - serial adapter hooked up to the CVTPRO300 box. I fire up HVACPRO, and try to pull up anything to see if the adapter is talking to...
  28. Replies
    7
    Views
    1,297

    Now I have to figure out what the heck is hogging...

    Now I have to figure out what the heck is hogging up my Com1 or Com2 port. Sometimes I hate Windows XP....
  29. Thread: Trane Summit

    by neonhomer
    Replies
    5
    Views
    934

    I know what you mean... not to go too far OT, but...

    I know what you mean... not to go too far OT, but I hate typing on a touchscreen device... that's why I love my BlackBerry.....

    I think it would be awesome if Trane released older versions of...
  30. Thread: Trane Summit

    by neonhomer
    Replies
    5
    Views
    934

    HUH? I have reprogrammed Comm5 AHU...

    HUH? I have reprogrammed Comm5 AHU controller's with Rover before, writing in routines and points to allow for O/A calibration, O/A Damper tracking, etc etc.



    However, Rover will not allow...
  31. Replies
    7
    Views
    1,297

    1400's I think.... I am not entirely sure....

    1400's I think.... I am not entirely sure....
  32. Replies
    7
    Views
    1,297

    Johnson balancing software

    Well, my new employer handed me one of these....

    http://airbalancestore.com/images/D/AS-CVTPRO300-1.jpg

    I need to find the Windows based VAV software for these... I have the Palm software and...
  33. Replies
    8
    Views
    1,446

    chillrdude, you have PM....

    chillrdude, you have PM....
  34. Replies
    8
    Views
    1,446

    Lemme look on my laptop when I get home. I...

    Lemme look on my laptop when I get home. I believe I have SP10 for ver 5...
  35. Old topic, different spin, and different...

    Old topic, different spin, and different employer!!

    I need the Johnson Controls PC balancing software. I have the Metasys box that goes from a serial port on my computer to a stat. It came with a...
  36. Replies
    8
    Views
    2,519

    The copy of WPT I have was licensed to me by a...

    The copy of WPT I have was licensed to me by a local TAC dealer. You might be able to contact TAC and they might be able to get you a copy of it on an academic basis if you prove your need.
  37. Replies
    4
    Views
    552

    Usually, Trane will only sell the Comm4 Service...

    Usually, Trane will only sell the Comm4 Service tool and Lon Air & Water balance tool. I was able to get the full monty, but it was a screw up. The only thing I know to do is to get the proper part...
  38. Replies
    1
    Views
    475

    KMC T&B Software

    Does anyone know where I can get the TAB software for KMC? We have a few laptops with the Wincontrol software on it, but they are older systems due for replacement. We need to be able to reinstall it...
  39. Replies
    3
    Views
    1,876

    Trane Rover BAS - Registration Q's

    This is not a big deal... just some ramblings...

    I was able to get my hands on a copy on Windows 7, and have it set up in a dual boot with my laptop and Windows XP. My boss has asked me to test...
  40. Replies
    8
    Views
    2,519

    WPT is not an application itself, but runs as a...

    WPT is not an application itself, but runs as a add-in to Visio.

    I can go into Task Manager and select to use one or both cores for a program, but I think you have to do it every time you run it....
  41. Replies
    8
    Views
    2,519

    Well, this laptop is about 5 yrs old or so......

    Well, this laptop is about 5 yrs old or so... It's a P4 3.2GHz, 2GB RAM, 320GB PATA hard drive, ATI chipset.

    I don't know what the deal is. I would LOVE to get a new laptop (any my company said...
  42. Replies
    8
    Views
    2,519

    TAC Workplace Tech - Locks up

    This is a bit of a royal PITA.... I am using Workplace Tech 5.72 (WPT) and Visio 2007. Job is BACNet, 12 MNB-1000's, about 55 VAVs, and a few other TAC BACNet devices. I have been connecting to the...
  43. Replies
    4
    Views
    605

    I have Rover 5, and I am going to install it so I...

    I have Rover 5, and I am going to install it so I can at least do my Monday job, which is all Comm 5/LON.... I have another commissioning job to do Tuesday that IIRC, requires both Comm4 and 5....
    ...
  44. Replies
    4
    Views
    605

    Great: Rover wont register

    This is great... when it rains it pours...

    Had a drive failure on my laptop that has Rover 7 installed on it. Managed to get everything reinstalled, and I am now in the process of getting all my...
  45. Replies
    19
    Views
    1,945

    Both the MNB1000 and MNL1000 have Ethernet and...

    Both the MNB1000 and MNL1000 have Ethernet and could be adjusted from my desktop computer. Of course that would require installing WPT on the desktop as well... not a cheap idea...
  46. Replies
    19
    Views
    1,945

    Controls in a residence?

    A friend of mine handed me two TAC MNL1000's, and a MNB1000 the other day that were dead. Long story short, the MNL1000's needed caps and a couple of transistors. The MNB needs a couple of caps and...
  47. Replies
    13
    Views
    1,327

    Try uninstalling Rover. If you have no other...

    Try uninstalling Rover. If you have no other trane software on your computer, make sure the c:\program files\common files\trane shared folder is gone as well.

    Reboot your system, make sure all...
  48. Replies
    9
    Views
    1,367

    I made a request to the general contractor to get...

    I made a request to the general contractor to get in touch with the JCI guy, but they seem to be more worried about their wood floor in their media center than us getting our job done.

    I am going...
  49. Replies
    9
    Views
    1,367

    I will have to find out what the IP address is...

    I will have to find out what the IP address is for the network so I can control it. I don't mind using the facilities' network to access it (I do the same thing for TAC), but I prefer to be able to...
  50. Replies
    9
    Views
    1,367

    Controlling Metasys

    This is going to be fun. I am on a job where the control guy is nowhere to be found. I need to control the system to do some T&B work.

    What software do I need for my laptop to be able to control...
Results 1 to 50 of 187
Page 1 of 4 1 2 3 4

Related Forums