07-10-2012, 10:01 AM
Thread: 30RA055 TXV
by RedWireGoesWere- Replies
- 4
- Views
- 552
M#30RAN055-511HW S#2305 The valve in there now...
M#30RAN055-511HW
S#2305
The valve in there now is a danfoss tre20 20TR 70Kw
The unit runs to a bath that there vats pull from when needed to cool down the beer during production. (working in a... -
07-07-2012, 12:16 PM
Thread: 30RA055 TXV
by RedWireGoesWere- Replies
- 4
- Views
- 552
Carrier says danfoss
Carrier supplier told me that the factorys answer was the number I was given was for a new danfoss. I td them I want the sporlan valve they have changed to so they are trying to get the part number...
-
07-05-2012, 08:12 AM
Thread: 30RA055 TXV
by RedWireGoesWere- Replies
- 4
- Views
- 552
30RA055 TXV
I was wondering if anyone here has changed out the danfoss txv on these machines with the new txv that carrier has for them. Part number 30RA502111. Is this just a new danfoss valve or did they...
-
07-05-2012, 08:03 AM
Thread: Busted Drier Cannister on a RTAA
by RedWireGoesWere- Replies
- 4
- Views
- 490
I use the same and I have also used PB Buster on...
I use the same and I have also used PB Buster on cooling tower motor bolts that are all corroded.
-
03-31-2010, 09:44 PM
- Replies
- 22
- Views
- 3,358
There probably cold. So they think those are...
There probably cold. So they think those are heaters that someone put out there for them to sit on while they have a smoke.
-
03-31-2010, 09:40 PM
Thread: Home Depot Install
by RedWireGoesWere- Replies
- 26
- Views
- 4,371
My Local HD has Trane. But they have a sales guy...
My Local HD has Trane. But they have a sales guy from the local Hvac company that installs it for them there on certain days to sell it and answer any questions.
-
02-21-2010, 09:33 PM
- Replies
- 14
- Views
- 2,545
We had a rebuild installed in a system once and...
We had a rebuild installed in a system once and the forgot to take what ever sandy speedy dry looking stuff they used out of the oil pan and sent it out to us. Plugged the oil pump and killed the...
-
02-21-2010, 09:20 PM
Thread: I prefer my furnace well done!
by RedWireGoesWere- Replies
- 14
- Views
- 1,902
The roll out switch is manual reset. Could be...
The roll out switch is manual reset. Could be some one kept resetting it. The roll out switch wires look like they are melted together which would explain it not tripping till they shorted to the...
-
02-20-2010, 10:33 PM
Thread: jerryrigged mobile home furnace
by RedWireGoesWere- Replies
- 18
- Views
- 1,637
At least there was a lot of room around that...
At least there was a lot of room around that miller. (At least it looked like a miller). Usually find those bad boys jammed in a closet.
-
02-05-2010, 09:08 PM
Thread: must have been cold
by RedWireGoesWere- Replies
- 5
- Views
- 1,059
Guy said that he had one of his fire department...
Guy said that he had one of his fire department buddies fix the unit a couple of years ago because he knew what he was doing. Guess his buddy wanted to come back on a real "fire" call.[/QUOTE]
... -
02-05-2010, 09:04 PM
Thread: Filter bandit?
by RedWireGoesWere- Replies
- 3
- Views
- 858
I like the Engineered filter rack they put in to...
I like the Engineered filter rack they put in to hold the filter in place. Adds a little something to it all.
-
01-24-2010, 11:17 PM
Thread: Compressor of Shame
by RedWireGoesWere- Replies
- 12
- Views
- 1,671
If I was grading him I would give him an F+. The...
If I was grading him I would give him an F+. The + is for at least putting a drier in.
-
01-23-2010, 07:22 PM
Thread: How long until.......
by RedWireGoesWere- Replies
- 13
- Views
- 2,030
I say first heavy snow storm there will be a...
I say first heavy snow storm there will be a service call coming in.
-
01-23-2010, 07:19 PM
Thread: It's automated!
by RedWireGoesWere- Replies
- 4
- Views
- 1,002
almost looks like a clap on clap off monitor.
almost looks like a clap on clap off monitor.
-
01-22-2010, 11:58 PM
Thread: A what were they thinking moment.
by RedWireGoesWere- Replies
- 3
- Views
- 290
A what were they thinking moment.
Another Company installs a 120,000 BTU gas furnace(2 years ago) in a town house that load Calculations sized for a 60,000 BTU Furnace. (When are people going to learn bigger is not better) Now we...
-
01-22-2010, 10:09 PM
Thread: I got my Testo 327-1!
by RedWireGoesWere- Replies
- 18
- Views
- 2,758
I have enjoyed working for a company that bought...
I have enjoyed working for a company that bought all the expensive toys for my job and it is nice not having to front the cash. But it does have a down side when they only want to buy 1 combustion...