Search:

Type: Posts; User: york56

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    11
    Views
    573

    Death of another brand name whose next. Because...

    Death of another brand name whose next. Because bigger is better !
  2. Replies
    5
    Views
    171

    Your welcome Sir.

    Your welcome Sir.
  3. Replies
    5
    Views
    171

    Check this out.

    Check this out.
  4. Replies
    5
    Views
    171

    Single line panel or Optiview panel ?

    Single line panel or Optiview panel ?
  5. Replies
    10
    Views
    466

    I was going to say the same thing I have seen...

    I was going to say the same thing I have seen this have the begining not the middle and have the end put in a repeater and problem solved also I would get those Diag485's out they are for...
  6. Replies
    10
    Views
    466

    You should have a BT485 at the LGR25 Arcnet...

    You should have a BT485 at the LGR25 Arcnet begining then at the last AAR left side where it ends then on the right side of the AAR where it goes out to vav's begining should have a BT485 and then at...
  7. Replies
    13
    Views
    488

    http://www.youtube.com/watch?v=D0n8N98mpes ...

    http://www.youtube.com/watch?v=D0n8N98mpes

    This career reminds me of this game the guy playing is your boss.
  8. Replies
    2
    Views
    296

    Depending on conditions indoors , outdoors...

    Depending on conditions indoors , outdoors rigging is all about being creative and saftey possible gantry , chain fall , etc. if it was easy anybody could do it.
  9. Replies
    3
    Views
    316

    You are most welcome.

    You are most welcome.
  10. Replies
    3
    Views
    316

    That is the IOM for a YS Style E don't think that...

    That is the IOM for a YS Style E don't think that you will find it anywhere online , but if you check your email you will find a surprise !
  11. Being from the HVAC side for many years has given...

    Being from the HVAC side for many years has given myself a broad range off experience and exposure but if you really want to expand your potential go for the controls side then you will have both...
  12. Replies
    6
    Views
    1,052

    Here you go b-man.

    Here you go b-man.
  13. TYPE1065 micro panel , PORT 1ISN R7 , PORT 21065...

    TYPE1065 micro panel , PORT 1ISN R7 , PORT 21065 micro panel

    This is what I am thinking for microgateway setup.
  14. TYPE 1065 micro panel , PORT 1 ISN R7 , PORT 2...

    TYPE 1065 micro panel , PORT 1 ISN R7 , PORT 2 1065 micro panel

    This is what I am thinking for microgateway setup.
  15. I would set it up the way this PDF explains it...

    I would set it up the way this PDF explains it has been awhile since I have even used this set up type I remember this because it was only out for awhile then they went to the quick start set up...
  16. Look at post #13 if you turn all the switches to...

    Look at post #13 if you turn all the switches to the on postion power down then power up you will be terminal mode then you would need to disconnect N2 wires and put your cable in its place now you...
  17. Here is the eprom data unless someone burned a...

    Here is the eprom data unless someone burned a special eprom one of these numbers should be in there.
  18. Here are part numbers for the microgateways

    Here are part numbers for the microgateways
  19. Find out also what number microboard is in the...

    Find out also what number microboard is in the chillers if you can.
  20. This is how a example how you would set up the...

    This is how a example how you would set up the address for the microgateway 1,2,4,8,16,32,64,cm are the binary address numbers the numbers just above those where the on switch is where you select...
  21. When you ask about the configurator are you...

    When you ask about the configurator are you speaking about the microgateway or the UDC ? also what is the microgateway dip switch set for 252 or 247 ? and could you tell me the eprom # on the chip...
  22. If you have had retrofit work done to that...

    If you have had retrofit work done to that chiller question is what type of panel is on it now single line or optiview , because a single line will be York Talk 2 V7 & a optiview will be York Talk 3...
  23. Replies
    21
    Views
    1,640

    Find a good Industrial oil fired boiler thats...

    Find a good Industrial oil fired boiler thats being demoed and if there is one piece of salvage that you want its the gear pump for that boiler the rest is up to you to modify it to your personal...
  24. If you have a N2 microgateway you need this.

    If you have a N2 microgateway you need this.
  25. Here is what I am thinking if you have one...

    Here is what I am thinking if you have one microgateway that appears to be the case here which I believe is talking to the UDC thru port 1 RS485 comm and the chiller data is then daisy chained back...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4