  1. Replies
    53
    Views
    4,405

    And you have to be impressed with some of the...

    And you have to be impressed with some of the entrance and exit ramps around here. They’re like 10 stories up!!!

    I found "The Holy Grail" pub in Plano. I think I’m going to like it here. :D
  2. Replies
    53
    Views
    4,405

    That's a fact! So where are all the brew pubs...

    That's a fact! So where are all the brew pubs around here anyway? And what is with all of this traffic!!! :gah:
  3. Replies
    32
    Views
    1,751

    You need two measurements to determine the state...

    You need two measurements to determine the state of the air.

    If you can measure dry bulb and wet bulb, you have it figured out.

    If you can measure dry bulb and relative humidity, you have it...
  4. Replies
    53
    Views
    4,405

    Seems appropriate that I mention this in this old...

    Seems appropriate that I mention this in this old thread. ;)

    I have resigned from Tecumseh Products on March 28th, and accepted a position as product manager for DunAn Precision Inc, a...
  5. Replies
    10
    Views
    807

    No. A couple of researchers by the names of Wolf...

    No. A couple of researchers by the names of Wolf and Pate did the actual correlation. The correlation used capillary tube flow tests with various refrigerants.

    The sordid details are published...
  6. Replies
    30
    Views
    1,636

    Bingo! As the tech services manager at Tecumseh,...

    Bingo! As the tech services manager at Tecumseh, there are all sorts of ways one can design a single phase motor for a compressor. One size fits all start components can be very useful diagnostic...
  7. Replies
    10
    Views
    807

    One other issue with the replacement refrigerants...

    One other issue with the replacement refrigerants is that they affect the capacity of the compressor. For example, an R-12 compressor on MP39, R-409A, or Hot Shot can deliver significantly more...
  8. Replies
    16
    Views
    1,138

    Sage advice... ;)

    Sage advice... ;)
  9. Replies
    10
    Views
    1,080

    POE oil is more resilient. The real problem here...

    POE oil is more resilient. The real problem here is motor windings will roast at these temperatures. Mineral oil would break down at these temperatures measured at the discharge line.


    Probably...
  10. Replies
    4
    Views
    543

    It is also a measure of the valve's rating. A...

    It is also a measure of the valve's rating. A valve with a nominal 1 ton rating and a 20 percent bleed will have a total 1.2 ton nominal rating. A 2 ton valve with a 20 percent bleed would have...
  11. Replies
    10
    Views
    1,080

    R-407A: R-32/R-125/R-134a (20/40/40) R-407F:...

    R-407A: R-32/R-125/R-134a (20/40/40)
    R-407F: R-32/R-125/R-134a (30/30/40)

    R-407F trades 10 percent R-125 for R-32. R-125 has a bad GWP. R-32 has a good GWP. Both R-407A and R-407F are way...
  12. Replies
    4
    Views
    543

    It means a 15 percent uncontrolled flow at the...

    It means a 15 percent uncontrolled flow at the valve's nominal rating conditions. Incidentally, this also increases the valve's capacity 15 percent at its nominal rating conditions.
  13. Life in the ASHRAE 34 Standards committee. ;)

    Life in the ASHRAE 34 Standards committee. ;)
  14. Replies
    28
    Views
    1,550

    You know things aren't going well for Obama when...

    You know things aren't going well for Obama when Charlie Rangel turns on him: http://cnsnews.com/news/article/melanie-hunter/rangel-i-love-obama-red-line-syria-embarrassing
  15. Wax was originally a problem with low temp...

    Wax was originally a problem with low temp systems using R-502 and mineral oil. The problem was significant enough to cause Sporlan to invent the "HH" filter-drier. The "HH" filter-drier...
  16. Not to confuse things here, but a supercritical...

    Not to confuse things here, but a supercritical fluid can become liquid if you remove enough heat from it. But this is not "condensing" in the classic sense... vapor becoming liquid. A...
  17. I agree. It clearly shows the supercritical...

    I agree. It clearly shows the supercritical region to be a dense something or other than cannot be defined as a vapor or liquid - or at least not having an vapor-liquid interface.
  18. The best definition of critical point, IMHO: the...

    The best definition of critical point, IMHO: the saturated state where the liquid and vapor phases
    become indistinguishable.

    At the critical point, you are still at saturation, but cannot...
  19. Replies
    3
    Views
    440

    Using R-502 with POE oil won't be a problem. I...

    Using R-502 with POE oil won't be a problem.

    I doubt going from R-404A to R-502 will give you any significant change in system capacity. Your problem likely lies elsewhere.

    Start by examining...
  20. Replies
    41
    Views
    2,335

    The math is simple either way... Add them up. ;)

    [/QUOTE]
    The math is simple either way... Add them up. ;)
  21. Replies
    98
    Views
    9,223

    Internal overloads do reset themselves. ;)

    Internal overloads do reset themselves. ;)
  22. Replies
    98
    Views
    9,223

    I know Wes very well. He is one that I pay...

    I know Wes very well. He is one that I pay attention to when he writes articles and commentary for our industry.

    My concern with a large R-407C refrigeration system using MO/AB oil with a...
  23. Replies
    98
    Views
    9,223

    Hydrocarbons are miscible with MO/AB oil. That...

    Hydrocarbons are miscible with MO/AB oil. That is why they are added to HFC refrigerants which, of course, are not miscible with MO/AB oil. The trick is to use enough hydrocarbons to get the MO/AB...
  24. Replies
    98
    Views
    9,223

    You're confusing HFC refrigerants having no...

    You're confusing HFC refrigerants having no hydrocarbons added and service replacement HFC refrigerants that do.

    Most everybody agrees having 95 percent POE oil in the system is unnecessary when...
  25. Replies
    17
    Views
    2,718

    Take a look at the "Refrigerant TP - PT Chart"...

    Take a look at the "Refrigerant TP - PT Chart" web app here: http://boxload.tecumseh.com/