  1. When in Atlanta when it reached 92° my ac would...

    When in Atlanta when it reached 92° my ac would run none stop and would not even drop the temp by 1° until it got below 90°. And no mine was not undersized as on cooler days 80°'s it would still run...
  2. Replies
    41
    Views
    668

    to answer more of you questions. I believe the...

    to answer more of you questions. I believe the reason it was freeing up on me after I replace the txv is I tried disconnecting the bulb to get my suction up. as stated in an earlier post I was...
  3. Replies
    41
    Views
    668

    Direct drive blowers, single 10 ton a-coil with 1...

    Direct drive blowers, single 10 ton a-coil with 1 txv, It is no longer freezing up, at least not the suction line after I saw it running for 3 hours straight and it was running before I got there so...
  4. Replies
    41
    Views
    668

    I know :gah: but i went prepared with a 1/2"...

    I know :gah: but i went prepared with a 1/2" drier and it was 5/8" I was there late so no supply houses were open when I discovered it. And since I do not do much work on larger equipment I only...
  5. Replies
    41
    Views
    668

    actually it is less thank 1.5* I checked today.

    actually it is less thank 1.5* I checked today.
  6. Replies
    41
    Views
    668

    tesp = return to between furnace and evap = .5...

    tesp = return to between furnace and evap = .5 on one furnace and .63 on the other. not sure if I add the two number together and or divide by 2.
    evap coil was .25 and .21 so no restriction at...
  7. Replies
    41
    Views
    668

    In my first post I mentioned readings before I...

    In my first post I mentioned readings before I replaced the txv and after I replaced the txv. Now I am not saying that I did not or could not have heated up the txv too much but I am thinking it is...
  8. Replies
    41
    Views
    668

    I do not have my note pad with me but the suction...

    I do not have my note pad with me but the suction pressure was 50# which will make the temp.in the 20*'s and my suction line temp was 30* warmer so roughly 50*'s so no it was not beer can cold. It...
  9. Replies
    5
    Views
    260

    won't put any extra strain on it at all.

    won't put any extra strain on it at all.
  10. look at your pictures and tell US they are the...

    look at your pictures and tell US they are the same exact part. They are not trying to argue with you. Just pointing out a fact. Something is not right on your end. And I do not mean name brand...
  11. Replies
    2
    Views
    223

    is the number apt58-3-1x? if so possibly 58,000...

    is the number apt58-3-1x? if so possibly 58,000 btu divided by 12,000 = 5 ton.
  12. Thread: Bugs

    by DOGBOY
    Replies
    8
    Views
    334

    I carry 2 or 3 if it is a high use part on my van...

    I carry 2 or 3 if it is a high use part on my van and if i get low i am at the supply house waiting on them to open to replace my missing parts. Also if they are smaller parts like caps, contactors,...
  13. Replies
    4
    Views
    240

    4 tons for 1600 sq. ft. where I am at is overkill.

    4 tons for 1600 sq. ft. where I am at is overkill.
  14. Replies
    41
    Views
    668

    I believe you 2 are right I went back and check...

    I believe you 2 are right I went back and check static pressures better and in more places and it is less than .7. I know this is a little high but should not be causing what i am seeing.
  15. Replies
    41
    Views
    668

    I have checked the blowers and they do run the...

    I have checked the blowers and they do run the correct direction however when I access the blower the blower switch opens and when I check the blower it is running right way. Any suggestions on how...
  16. Replies
    41
    Views
    668

    10 ton split freezing up

    So I have a 10 ton condensing unit on 2 gas furnaces with 5 ton drives, and blowers are wired for high. Ever since I have seen this unit it has been freezing up about 1 yr now but they say it has...
  17. Replies
    9
    Views
    313

    aprilaire has merv 13

    aprilaire has merv 13
  18. Replies
    9
    Views
    313

    if it is an aprilaire why not go with an...

    if it is an aprilaire why not go with an aprilaire replacement filter?
    ...
  19. it was manufactured in either 1967, 1968 or 1969 ...

    it was manufactured in either 1967, 1968 or 1969 it was 35,000 btu and was a 7 seer/eer according to carriers THE BLUE BOOk.
  20. Replies
    15
    Views
    805

    [QUOTE=Takete;18754011]Well... I realy need so...

    [QUOTE=Takete;18754011]Well... I realy need so help...

    RHEEM 5 ton
    Condensate: 13AJN60A01
    Air handler: RHLL-HM6024JA

    When I see it have a lot pressure 160 in low and 430 in high..[QUOTE]
    ...
  21. Replies
    9
    Views
    313

    In my opinion (if that is worth anything) the 4...

    In my opinion (if that is worth anything) the 4 or 5 inch media filters are among the best protection you can have for your evaporator coil to keep it clean. It for sure is cheaper to replace the...
  22. as teddy bear said try it for yourself and that...

    as teddy bear said try it for yourself and that way you have no one to argue with. Some instances it will put humidity back into the house (most all instances) some instances it does not put...
  23. So exactly how do you get walmart and the grocery...

    So exactly how do you get walmart and the grocery stores to sell you items at the same prices they pay for them?
  24. why could it not be a restricted circuit or 2?

    why could it not be a restricted circuit or 2?
  25. Replies
    3
    Views
    239

    wow someone actually understands and isn't pissed...

    wow someone actually understands and isn't pissed off about it. Liability that is. Cool