    sloppy workmanship the foil tape looks like a...

    sloppy workmanship the foil tape looks like a hack installed it.the duct tape around the lineset looks unprofessional and the condenser is too close to the wall.id post it in the hall of shame pics.
  2. Replies
    10
    Views
    796

    check out http://www.mrslim.com

    check out http://www.mrslim.com
  3. ask your contractor to provide you with a load...

    ask your contractor to provide you with a load calculation.this will ensure you of getting the proper size equipment.you can do your own by clicking hvac load calc its worth it to be sure.thanks
  4. Replies
    7
    Views
    3,437

    check out http://www.mrslim.

    check out http://www.mrslim.
  5. Thread: Noisy ducts

    by jeffshvac
    Replies
    4
    Views
    727

    its hard to diagnose sounds over the...

    its hard to diagnose sounds over the internet.this is something a qualified hvac contractor will need to hear to pinpoint your problem.usually these noises can be caused by poor workmanship and...
  6. Replies
    20
    Views
    1,648

    yes its possible to keep your old furnace any...

    yes its possible to keep your old furnace any good hvac contractor has the skills to install a new coil by making the duct adaptations that are necessary.the furnace being 15 years old its probably...
  7. Replies
    35
    Views
    1,978

    i get the feeling the pics may be transferred...

    i get the feeling the pics may be transferred over to the wall of shame.this tends to happen when contractors have inexperienced helpers installing hvac systems.its up to the contractor to make sure...
  8. Replies
    35
    Views
    1,978

    they can be wrapped after installation but doing...

    they can be wrapped after installation but doing so takes twice the time and working in the crawlspace is usually a difficult task.expect to be charged accordingly.taking the lowest priced bid is...
  9. Replies
    35
    Views
    1,978

    if theres plumbing pipes in the crawl cutting in...

    if theres plumbing pipes in the crawl cutting in a register is ok to prevent freeze ups.also a 4 ton system cooling 1400 sq ft sounds way oversized.did this contractor do a load calculation on your...
  10. Replies
    35
    Views
    1,978

    insulating the ducts is the proper thing to do...

    insulating the ducts is the proper thing to do when installing ductwork in an unconditioned crawlspace.they need to be wrapped with insulation before they are installed.it sounds like your contractor...
  11. Replies
    8
    Views
    2,391

    and judging by your spelling and forming of a...

    and judging by your spelling and forming of a complete sentence you may not be ready to write up any contracts or invoices without help either ...lol
  12. Replies
    17
    Views
    1,547

    hackery is the term we use for installations that...

    hackery is the term we use for installations that dont meet up to proper standards.usually these companies hire out contractors that are paid a portion of the cost for installing your equipment.they...
  13. Replies
    17
    Views
    1,547

    i would stay away from sears and home depot.they...

    i would stay away from sears and home depot.they subcontract all their work out and ive seen some hackery over the years.they also have the highest prices around.get a few estimates from reputable...
  14. Thread: rheem unit

    by jeffshvac
    Replies
    11
    Views
    975

    if you keep hitting it enough times im sure youll...

    if you keep hitting it enough times im sure youll jar something else loose,this should be diagnosed by qualified hvac contractor.like stated check all wiring,inducer and blower door.
  15. Thread: New Furnace

    by jeffshvac
    Replies
    6
    Views
    702

    we dont give pricing and installing your own...

    we dont give pricing and installing your own system is not recommended.this is something a qualified hvac contractor should be doing.
  16. Thread: Air Handler

    by jeffshvac
    Replies
    26
    Views
    1,662

    most air handler drain pans can be replaced or...

    most air handler drain pans can be replaced or fabricated as stated .also you should have an emergency secondary drain pan under the air handler.having a qualified hvac contractor check your system...
  17. Replies
    26
    Views
    1,805

    i may be mistaken but i thought advertising your...

    i may be mistaken but i thought advertising your own site was against the rules in this forum.and doing a load calc is something that professionals should do.even a newbie knows that.
  18. Replies
    12
    Views
    918

    you can get away with it being 10 inches away...

    you can get away with it being 10 inches away from the house as long as the service panel is accessable from the side.as a contractor i wouldnt leave it up to you to set up the distance its his...
  19. Thread: No Heat

    by jeffshvac
    Replies
    13
    Views
    1,097

    according to your profile your occupation is...

    according to your profile your occupation is hvac,im sure you know what could cause gas valve chattering.giving you an online diagnosis of this problem is against site rules.
  20. Thread: No Heat

    by jeffshvac
    Replies
    13
    Views
    1,097

    ask yourself this...is saving a few extra dollars...

    ask yourself this...is saving a few extra dollars really worth your families safety?having a service call done on a sunday is sometimes necessary.ignoring this problem and using the furnace is not...
  21. Thread: ducane

    by jeffshvac
    Replies
    13
    Views
    1,392

    if your currently selling goodman you can offer...

    if your currently selling goodman you can offer either of the two has your high end equipment.id go with the heil.
  22. Replies
    9
    Views
    3,294

    with the proper installation the york affinity is...

    with the proper installation the york affinity is a nice system.www.yorkupg.com
  23. we dont put returns in kitchens or bathrooms have...

    we dont put returns in kitchens or bathrooms have them relocate it while they still can.return air will circulate provided the doors are undercut to allow it.
  24. properly sizing your ductwork is an important...

    properly sizing your ductwork is an important part of a new furnace installation.the ducts can be designed for your system so that they can save you space and still work properly.having a qualified...
  25. Replies
    8
    Views
    1,515

    i suggest having your contractor do a load...

    i suggest having your contractor do a load calculation to determine the proper equipment sizing.this will ensure your getting the most efficient system possible.