  1. if you get the increase you may also be blowing...

    if you get the increase you may also be blowing water off of the coil.
  2. Replies
    27
    Views
    1,418

    I had someone wire up a 3 phase sump heater in a...

    I had someone wire up a 3 phase sump heater in a cooling tower some 20+ years ago and I told him if the heater starts to "cool" the water instead of heating the water what does he need to do? he...
  3. Replies
    8
    Views
    528

    his recovery machine will not pull it down...

    his recovery machine will not pull it down enough. a good one might do 15-25". microns will still be in the thousands.
  4. Replies
    20
    Views
    875

    this is not a DIY site.

    this is not a DIY site.
  5. Replies
    11
    Views
    509

    Go to Goodman website and read their warranty. If...

    Go to Goodman website and read their warranty. If I buy a Goodman unit and install it they only warranty parts, not labor. I can offer labor warranty but it is not through Goodman. Sometimes you can...
  6. Replies
    22
    Views
    1,057

    I thought about being a beach bum

    I thought about being a beach bum
  7. I would want to see the start up data such as...

    I would want to see the start up data such as superheat readings, amp draws, electrical connections checked, gas pressure in and manifold pressure, temp rise, static pressure and so on. I bet none of...
  8. Replies
    15
    Views
    835

    what is the btu rating of the gas from the well?

    what is the btu rating of the gas from the well?
  9. just buy a window unit and be done with it.

    just buy a window unit and be done with it.
  10. Replies
    37
    Views
    3,011

    Joe you got the answers right, did you get a...

    Joe you got the answers right, did you get a offer?
  11. they both fit the same case, the 6100 is a heat...

    they both fit the same case, the 6100 is a heat pump and the 4100 is not.
  12. Replies
    40
    Views
    1,964

    by the number of ads I would say the turn over...

    by the number of ads I would say the turn over rate is high. maybe he just cant find quality people. or never found anyone.
  13. Replies
    11
    Views
    901

    the school says once done Im certified as a HVAC...

    the school says once done Im certified as a HVAC tech in all 50 states

    this is not true. in Kansas I carry a masters license and it is worthless in Oklahoma. Oklahoma license is worthless here in...
  14. it is not wired right. t1 and t2 needs 24v from...

    it is not wired right. t1 and t2 needs 24v from heater. you are right on "r" being +24v. G is not common. G is normally for fan relay.
    This is not a do it your self site so I cant go any further. A...
  15. I would try the boiler next.

    I would try the boiler next.
  16. and out of that profit comes insurance, license,...

    and out of that profit comes insurance, license, taxes, truck charge, office-shop, office help, I could go on.
  17. Replies
    1
    Views
    394

    drain the oil from the oil separator in to a...

    drain the oil from the oil separator in to a clean recovery cylinder and pull the vapors out of the cylinder back into the chiller.
  18. is this black stuff anywhere else such as return...

    is this black stuff anywhere else such as return air grills, duct work? which side of the filter is it building up on, furnace side or duct side? any one know of a lab that filter can be sent to so...
  19. this is not a diy site. if you have a tech doing...

    this is not a diy site. if you have a tech doing the work let them get the part. then they are responsible for any warranty issues.
  20. Replies
    19
    Views
    996

    sounds like a diy blaming someone else on here to...

    sounds like a diy blaming someone else on here to try to get answers.
  21. this is not a diy site

    this is not a diy site
  22. Replies
    11
    Views
    600

    have bandage ready

    have bandage ready
  23. Replies
    7
    Views
    659

    another DIY?

    another DIY?
  24. Replies
    4
    Views
    424

    I used to replace txv with a r12 valve and...

    I used to replace txv with a r12 valve and charged with r12. but that was then. you could probably do 134a txv and replace oil to convert over.
  25. Questions and discussions pertaining to HVAC for...

    Questions and discussions pertaining to HVAC for the home. No pricing, no DIY, please read Site Rules Register