Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: yroy

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    7
    Views
    2,620

    When the compressor board is requested to start...

    When the compressor board is requested to start the compressor, it does it, then waits for a certain number of seconds. It then looks up the compressor proof input. If the proof signal is not...
  2. Replies
    7
    Views
    2,620

    Tech support has always been free. Except for one...

    Tech support has always been free. Except for one supermarket chain where most refrigeration techs are given very few permissions as requested by the chain headquarters. In this case, as instructed...
  3. Replies
    31
    Views
    4,655

    LOL, :grin2:.

    LOL, :grin2:.
  4. Replies
    31
    Views
    4,655

    Hello mspanky, Sorry to hear you had such bad...

    Hello mspanky,

    Sorry to hear you had such bad experiences with MT products. I have been working for MT for 15 years. I'm in Research and Development, not Sales or Marketing. Let me know if you...
  5. Thread: RPC server error

    by yroy
    Replies
    10
    Views
    1,451

    If the Andover application that fails happens to...

    If the Andover application that fails happens to be written as a windows service, then I suggest you go to:
    control panel
    administrative tools
    services
    - locate the andover continuum service in...
  6. Thread: RPC server error

    by yroy
    Replies
    10
    Views
    1,451

    This will probably not help.... This message...

    This will probably not help....

    This message is basically saying that application A tried to invoke a procedure in application B, and application B failed to respond in a timely fashion.
    ...
  7. Replies
    11
    Views
    1,175

    This is the first version. Yes you would need one...

    This is the first version. Yes you would need one per section. Of course, what you are suggesting makes more sense, so we will get there eventually. But we have to start somewhere.
  8. Replies
    11
    Views
    1,175

    this is a dedicated board with a dedicated...

    this is a dedicated board with a dedicated application. The installer specifies the refrigerant type, the valve and sensor models, the direction of defrost, what to do with the fan and the valve...
  9. Replies
    11
    Views
    1,175

    Dual Temp CO2 coffin controlled by EEV only

    Hello,

    Just want to share something we are proud of. This is an actual discharge temperature graph of a dual temperature CO2 coffin using direct expansion. None of the traditional dual temp...
  10. Replies
    31
    Views
    2,747

    CO2 is not on the list of refrigerants under...

    CO2 is not on the list of refrigerants under regulation by the EPA. And that is a reason why supermarkets are looking at CO2. Our customers tell us they are fed up with the paperwork tracking proofs,...
  11. Replies
    31
    Views
    2,747

    Hello pdrake65, A faily good single source of...

    Hello pdrake65,

    A faily good single source of info is r744.com. Create your account (easy), then you can browse and download any documentation and articles you want.

    I did not mean to...
  12. Replies
    31
    Views
    2,747

    Well I can only speak from personal experience....

    Well I can only speak from personal experience. We are an electronic OEM selling controls to supermarkets, rack and case OEMs, and refrigeration companies.

    So far, our controls have made it in...
  13. Replies
    31
    Views
    2,747

    Monumental CO2 Misinformation

    Someone obviously feals threatened by the success of CO2 as a refrigerant. A monumental masterpiece of misinformation, but I loved it. Really fun to hear.
    ...
  14. Thread: Snvt ?

    by yroy
    Replies
    5
    Views
    876

    Indeed. A SNVT_time_stamp wether #LO or not,...

    Indeed.

    A SNVT_time_stamp wether #LO or not, is on the network, always a SNVT_time_stamp. It is only the supervisory software based on LNS that can format it to be readable by a human in...
  15. Replies
    17
    Views
    1,700

    Well, I am just back from the Euroshop in...

    Well, I am just back from the Euroshop in Germany.

    My company wanted me to go. Why refuse a trip to Germany? Sounds fun! I did go wondering why are there still trade shows in this day and age.
    ...
  16. Thread: Snvt ?

    by yroy
    Replies
    5
    Views
    876

    Formatting: SNVT_time_stamp: text("%d/%d/%d...

    Formatting:

    SNVT_time_stamp: text("%d/%d/%d %d:%d:%d", year, month, day, hour, minute, second);

    SNVT_time_stamp#LO: text(date(year, month, day), (" "), time(hour, minute, second));
  17. Replies
    7
    Views
    2,620

    Hello MickeySq, So very very much better,...

    Hello MickeySq,

    So very very much better, across the board. Working conditions, health plans, retirement plans, everything is better. The Sporlan people and Parker Hannifin Corporate people are...
  18. Replies
    26
    Views
    1,788

    Being a control OEM, we have been involved in 8...

    Being a control OEM, we have been involved in 8 CO2 supermarkets so far. First one was low temp rack only (loop system with pumps). The 5 subsequent ones were direct expansion with compressors for...
  19. Replies
    7
    Views
    2,620

    Parker acquires Micro Thermo Technologies

    Just a few words to let you guys know that the "microthermites" are very pleased that we have been acquired by Parker Hannifin. We say goodbye and good luck to our Carrier friends.
    :pileon:
  20. Replies
    44
    Views
    3,803

    My guess is that there will eventually be a war...

    My guess is that there will eventually be a war between silicon based lifeforms that have ethnical differences. These ethnical differences will spur from their generic microprocessor heritage (intel...
  21. Replies
    4
    Views
    625

    control panel administrative tools services...

    control panel
    administrative tools
    services
    select ms sql in the list
    select properties
    select recovery tab
    make sure to select restart service on first failure, second failure and subsequent...
  22. Yes the only way the LNS license can expire is if...

    Yes the only way the LNS license can expire is if you have been running in deficit credits for more than 15? days.

    You can add credits by running c:\lonworks\bin\lnslic.exe
    Fill a form, contact...
  23. Replies
    64
    Views
    6,049

    Back to CO2 training.... Just got the Parker...

    Back to CO2 training....

    Just got the Parker (Sporlan) Catalog 744, january 2010 entitled 'subcritical CO2 innovations for supermarkets'. Can't find a link on their website yet.
  24. Replies
    64
    Views
    4,563

    Thank the lord for emergency relief valves.:grin2:

    Thank the lord for emergency relief valves.:grin2:
  25. Replies
    64
    Views
    4,563

    Exactly. And... A little bit of salt is good for...

    Exactly. And... A little bit of salt is good for you. Too much salt is not. Cars do release CO2. Millions and millions of cars release a lot of CO2. Every thing is now measured and compared to CO2...